My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2017 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231435
>
COMPLIANCE INFO 2017 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/5/2019 11:51:06 AM
Creation date
8/5/2019 9:15:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2017 - 2018
RECORD_ID
PR0231435
PE
2361
FACILITY_ID
FA0000916
FACILITY_NAME
7-ELEVEN INC #19976
STREET_NUMBER
1399
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21633034
CURRENT_STATUS
01
SITE_LOCATION
1399 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
123
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 <br />6_ PIPING SUMP TESTING <br />Test Method Developed By: <br />❑ Sump Manufacturer M Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: <br />❑ Pressure <br />❑ Other (Specify) <br />❑ Vacuum <br />N Hydrostatic <br />Test Lquipment USC& INCON SUMP TESTER <br />f;quipment Resolution: 0.002" <br />-- <br />Sump # T-4 87 STP <br />Tsump # T-5 91 STP <br />Sump # Sump # <br />Sump Diameter: <br />48" <br />48" <br />Sump Depth: <br />56" <br />56" <br />Sump Material: <br />Fiberglass <br />Fiberglass <br />Height from Tank Top to Top of <br />Hi est Piping Penetration: <br />15" <br />15" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />20" <br />20" <br />ENVIRaN^�+ <br />NTS_ HEALTH <br />Condition of sump prior to testing: <br />Dry <br />Dry <br />D -� JA <br />Portion of Sump Tested' <br />2"1 Penetrations <br />2"1 Penetrations <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />and water)?* <br />❑Yes [:]No NNA <br />❑Yes ❑No NNA <br />❑Yes ❑No ❑NA <br />[—]Yes ❑No <br />❑NA <br />-product <br />Turbine shutdown response time <br />N/A <br />NIA <br />is system programmed for fail-safe <br />shutdown? <br />❑�'� ]No ®NA <br />[:]Yes ❑No ®NA <br />❑Yes ❑No ❑NA <br />❑Yes ❑No <br />❑NA <br />Was fail-safe verified to be <br />operational?* <br />Dyes ❑No NNA <br />❑Ycs ❑No ®NA <br />❑Yes [:]No ❑NA <br />❑Yes ❑No <br />❑NA <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: <br />10 min <br />10 min <br />Test Start Time: <br />9:31 am <br />9:31 am <br />Initial Reading (Rt): <br />5.1176" <br />5.7382" <br />Test End Time: <br />9:46am <br />9:46am <br />Final Reading (RF): <br />5.1178" <br />5.7380" <br />Test Duration: <br />15min <br />15min <br />Change in Reading (RF -Rt): <br />+0.0002" <br />-0.0002" <br />Pass/Fail Threshold or Criteria: <br />+1-0.00211 <br />+/-0.002" <br />+1-0.00211 <br />+1-0.00211 <br />Test Result: <br />N Pass ❑ Fail <br />N Pass ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Was sensor removed for testing? <br />NYes ❑No [INA <br />NYes []No [INA <br />❑Yes []No [:]NA <br />Elves ❑No <br />❑NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />®Yes [:]No❑NA <br />NYes ❑No ❑NA <br />❑Yes [:]No [INA <br />[]Yes❑No <br />❑NA <br />Comments —(include information on repairs made prior to testing; and recommended follow-up forfailed tests) <br />If the entire depth of the sump is not tested, specify how much was tested. If the answer to as of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested.. (See SWRCB LG -160) <br />