My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0011836
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
2600 - Land Use Program
>
PA-1800090
>
SU0011836
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/18/2023 10:35:38 AM
Creation date
9/4/2019 10:04:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0011836
PE
2656
FACILITY_NAME
PA-1800090
STREET_NUMBER
9999
Direction
S
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336-
APN
20106003, -05, 18115007, -16
ENTERED_DATE
6/26/2018 12:00:00 AM
SITE_LOCATION
9999 S AUSTIN RD
RECEIVED_DATE
8/15/2023 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
FilePath
\MIGRATIONS\A\AUSTIN\9999\PA-1800090\SU0011836\APPL.PDF \MIGRATIONS\A\AUSTIN\9999\PA-1800090\SU0011836\EHD COND.PDF \MIGRATIONS\A\AUSTIN\9999\PA-1800090\SU0011836\DRAFT SEIR-09-2018.PDF \MIGRATIONS\A\AUSTIN\9999\PA-1800090\SU0011836\EIR-07-2018.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1399
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Draft Supplemental Environmental Impact Report Page IV.G-17 <br /> Forward Inc. Landfill 2018 Expansion Project <br /> As described in the Project Description, State and Federal standards have been established for <br /> the siting, design, construction, operation, closure, and post-closure of Class II landfills. <br /> Similarly, the closed Class I landfill has post-closure monitoring and maintenance requirements. <br /> These standards incorporate state-of-the-art engineering requirements that are intended to <br /> reduce the risks associated with waste disposal facilities to an acceptable level. An inconsistency <br /> between the proposed project and regulations related to surface or groundwater hydrology and <br /> water quality also would have the potential to result in significant impacts. <br /> Impact G.1: If rainfall runoff was not properly controlled, surface water bodies could become <br /> contaminated through contact with the landfill refuse. <br /> If rainwater falling on the new landfill area contacts the landfill refuse and picks up dissolved <br /> contaminants and is not controlled by the drainage system,surface water could migrate to <br /> Littlejohns Creek and flow downsteam to the San Joaquin River. The applicant's report for the <br /> relocation of the South Branch of South Littlejohns Creek report (Questa Engineering 2017) <br /> recommends a project design feature that would control landfill and site drainage run-on and <br /> runoff, so that run-on and run-off would be controlled and channeled to onsite stormwater/ <br /> sedimentation ponds. <br /> The drainage study utilizes San Joaquin County local rainfall data, and the Rational Method <br /> was used to estimate maximum potential runoff from a 1,000-year,24-hour event. The 1,000- <br /> year,24-hour storm criteria is a RWQCB requirement for Class II landfills. The surface water <br /> control system and drainage control structures for the proposed project are sized to <br /> accommodate the calculated peak flows. The proposed surface water control system would also <br /> divert run-on from properties surrounding the landfill. <br /> The following surface water management procedures are proposed as part of the proposed <br /> expansion project: <br /> • The drainage study utilizes San Joaquin County local rainfall data, and the Rational Method <br /> would be used to estimate maximum potential runoff from a 1,000-year,24-hour storm <br /> event. The surface water control system and drainage control structures for the proposed <br /> project would be sized to accommodate the calculated peak flows. <br /> • As part of the design plans for the proposed landfill expansion,Forward will complete <br /> calculations of the 1000-year, 24-hour storm event peak discharges. The hydraulic and <br /> drainage study would be used to design appropriate drainage controls. Drainage controls <br /> would be designed to prevent contact between surface water and refuse. Site run-on and <br /> run-off control facilities consist of drains and perimeter ditches that channel surface water to <br /> holding and evaporation ponds on the site. The surface-water collection drain system would <br /> be designed to divert the water to the onsite sedimentation basins. All waste at the proposed <br /> Forward Landfill would be separated from the North and South Branches of South <br /> Littlejohns Creek by a levee system or other acceptable method designed to protect the site <br /> from a 100-year flood event. <br />
The URL can be used to link to this page
Your browser does not support the video tag.