Laserfiche WebLink
d. A yearly permit to operate a public water system under the provisions of Title 22, CCR, <br /> will be required by the Environmental Health Division and San Joaquin County Ordinance <br /> 1862, Section 5-4100. The application shall be submitted within five weeks of the <br /> application's effective date. <br /> Y <br />} <br /> e. Connection to an approved public water supply system is required. The well must meet <br /> f. the following minimum standards within five weeks of the application's effective date: <br /> (1) Water quality shall be tested to meet Title 22, CCR, Safe Drinking Water Act <br /> requirements. <br /> (2) Water quantity shall be tested to show an adequate source. <br /> ® f. The well must be repaired under permit and inspection by the Environmental Health <br /> Division (San Joaquin County Ordinance 1862, Section 5-4100). Raise the well casing <br />+ 12 inches above ground level. The repair shall be completed within five weeks of the <br />' application's effective date. <br /> I g. Submit three sets of food facility construction plans to the Environmental Health Division <br /> for review and approval prior to June 21, 1993 (California Health and Safety Code, <br /> Section 27550). <br /> 4. BUILDING INSPECTION DIVISION: <br /> a. The following Uniform Building Code and San Joaquin County Ordinance requirements <br /> will be applicable and shall be incorporated in the construction plans before submittal to <br /> the Building Inspection Division: <br /> (1) The current use has changed the occupancy from a B-2 occupancy (Warehouse) <br /> to an A-2.1 occupancy (Assembly) (UBC Section 502). The structure must be <br /> brought into compliance with all current code provisions including structural, <br /> plumbing, mechanical, electrical, energy, and disabled access requirements. <br /> (2) Provide additional restrooms conforming with all disabled access requirements <br /> (CCR, Title 24). <br /> (3) The existing structure exceeds the allowable floor area permitted by the Uniform <br /> Building Code for an A-2.1 occupancy. The building shall be provided with an <br /> automatic fire sprinkler system. In lieu of sprinklers,the French Camp Fire District <br /> and the Building Inspection Division may approve an alternative that meets <br /> applicable Uniform Building and Fire Codes. <br /> (4) Provide an exit system that meets the requirements for an A-2.1 occupancy. <br /> (5) Provide a commercial hood in the kitchen that complies with all Uniform <br /> Mechanical and Fire Codes. <br /> (6) Exterior walls less than 10 feet from a property line shall be constructed of two- <br /> hour fire resistive material. Openings are required to be protected less than 10 <br /> feet and not permitted less than 5 feet from a property line (UBC Table 5A). <br /> i <br /> Conditions of Approval -4 - UP-92-31 <br /> i <br /> l <br />