My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0011787
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DAVIS
>
21600
>
2600 - Land Use Program
>
PA-1800093
>
SU0011787
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:35:26 AM
Creation date
9/4/2019 5:20:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0011787
PE
2631
FACILITY_NAME
PA-1800093
STREET_NUMBER
21600
Direction
N
STREET_NAME
DAVIS
STREET_TYPE
RD
City
LODI
Zip
95242-
APN
01308043
ENTERED_DATE
5/2/2018 12:00:00 AM
SITE_LOCATION
21600 N DAVIS RD
RECEIVED_DATE
5/1/2018 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
TSok
Supplemental fields
FilePath
\MIGRATIONS\D\DAVIS\21600\PA-1800093\SU0011787\APPL.PDF \MIGRATIONS\D\DAVIS\21600\PA-1800093\SU0011787\CDD OK.PDF \MIGRATIONS\D\DAVIS\21600\PA-1800093\SU0011787\EH PERM .PDF \MIGRATIONS\D\DAVIS\21600\PA-1800093\SU0011787\EHD COND.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(1) All winery driveways and maneuvering areas shall be surfaced and permanently maintained <br /> with base material of appropriate depth and chip seal to provide a durable, dust free surface. <br /> Bumper guards shall be provided when necessary to protect adjacent structures or properties. <br /> (Development Title Section 9-1015.5[e]) <br /> (2) A minimum of thirty-three (33) parking spaces shall be provided, including-one van accessible <br /> space, at full buildout. A minimum of eight (8) parking spaces shall be provided in Phase 1. A <br /> minimum of thirteen (13) parking spaces shall be provided in Phase 2. A minimum of thirteen <br /> (13) parking spaces shall be provided in Phase 3. (Each 1,000 square feet of building area <br /> requires 2.5 parking spaces.)(Development Title Section 9-1015.3) <br /> (3) Parking spaces for persons with disability shall be provided as required by Chapters 11A and <br /> 1-1 B of the California Building Code. <br /> g. ACCESS AND CIRCULATION: The following requirements apply and shall be-shown on the Site <br /> Plan: <br /> (1) Access driveways shall have a width of no less than twenty-five (25)feet for two-way aisles and <br /> sixteen (16) feet for one-way aisles, except that in no case shall driveways designated as fire <br /> department access be less than twenty(20)feet wide. (Development Title Section 9-1015.5[h][1]) <br /> h. SCREENING: Screening shall be provided and comply with the following: <br /> (1) All project storage materials and related activities, including storage areas for trash, shall be <br /> screened so as not to be visible from adjacent properties and public right-of-ways.-Screening shall <br /> be six (6) to seven (7)feet in height. Outside storage is not permitted in front yards, street side <br /> yards, or in frontofmain buildings. (Development Title Section 1022:4[d][2]) <br /> i. SIGNS:Sign details shall be consistent with Chapter 9-1710 and 9-1075.9(k)of the Development Title- <br /> and be included on the Site Pian.All portions of any sign shall be set back a minimum of five (5)feet <br /> from any future right-of-way line, including any corner cut-off(snipe). (Development Title Section 9- <br /> 1710.2[g]) <br /> j. BUILDING CODE REQUIREMENTS: The following California Building Code(CBC)and San Joaquin <br /> County Ordinance requirements will be applicable to the proposed project. The following conditions <br /> shall be addressed prior to submittal of a building permit application to the Building Inspection Division: <br /> (1) A building permit for each separate structure or building is required. Submit plans, specifications <br /> and supporting calculations, prepared by a Registered Design Professional(architect or engineer) <br /> for each structure or building, showing compliance with The 2016 California Building, Existing <br /> Building, Mechanical, Plumbing, Electrical, Energy and Fire Codes as may be applicable. Plans <br /> for the different buildings or structures may be combined into a single set of construction <br /> documents. <br /> (2) A grading permit will be required for this project. Submit plans and grading calculations, including <br /> a statement of the estimated quantities of excavation and fill, prepared by a Registered Design <br /> Professional.The grading plan shall show the existing grade and finished grade in contour intervals <br /> of sufficient clarity to indicate the nature and extent of the work and show in detail that it complies <br /> with the requirements of the code.The plans shall show the existing grade on adjoining properties <br /> in sufficient detail to identify how grade changes will conform to the requirements of the code. <br /> (3) The required plans must be complete at the time of submittal for a building permit. Plans must <br /> address building design and construction, fire and life safety requirements, accessibility and show <br /> compliance with the current California codes and San Joaquin County ordinances.A complete set <br /> PA-1800093 (SA) Conditions of Approval <br />