Laserfiche WebLink
areas shall be surfaced and permanently maintained with asphalt concrete or Portland <br /> cement concrete. However, Development Title Section 9-1015.9 allows requirements of <br /> the Parking and Loading Chapter to be modified by the Director in cases where it is <br /> demonstrated that the requirements may be considered insufficient or excessive. The <br /> applicant submitted a letter dated May 27, 2014 requesting that areas used for parking <br /> and maneuvering be surfaced with chip seal due to the cost of asphalt concrete and <br /> Portland cement concrete. The Community Development Department has reviewed the <br /> request and has determined that areas used for maneuvering and parking of trucks must <br /> be surfaced with asphalt concrete or Portland cement concrete for the Truck Sales & <br /> Services — Repairs use type. All other areas that are used for vehicular traffic can be <br /> surfaced and permanently maintained with a chip seal. Aggregate base may be used for <br /> trailer storage areas. The parking spaces and surface material must clearly be shown on <br /> the Improvement Plan. <br /> Access <br /> Development Title Section 9-1015.5(h)(1) states, "Access driveways shall have a width <br /> of no less than twenty-five (25) feet for two-way aisles and sixteen (16) feet for one-way <br /> aisles except that in no case shall driveways designated as fire department access be less <br /> than twenty (20) feet wide." The circulation patterns for ingress and egress traffic and <br /> aisle widths must clearly be shown on the Improvement Plan. <br /> Sign Modification <br /> The proposed project consists of a sign modification pursuant to Development Title <br /> Section 9-1710.40) to modify the maximum permitted square footage per sign face for <br /> two proposed pole signs. The applicant is requesting to modify the sign face for two <br /> pole signs from the maximum permitted 60 square feet for each sign to 140 square feet <br /> and 80 square feet. The 140 square foot pole sign is located along the westerly property <br /> line adjacent to Interstate 580 and the 80 square foot pole sign is located along the <br /> easterly property line adjacent to Hansen Road. The Community Development <br /> Department has reviewed the request and has determined the modification of <br /> requirements are consistent with the findings in Development Title Section 9-1710.4 <br /> (j)[1] & [2] <br /> 1. The proposed signs are consistent with the size of the facility and related <br /> structures, the location of the public access to the development, and other <br /> signage in the vicinity. <br /> This finding can be made because the proposed sign is consistent with the <br /> aggregate square footage of the proposed facilities and will not alter the <br /> current uses on adjacent properties and related structures. <br /> 2. The height, size and number of the proposed signs are the minimum required to <br /> identify and direct the public to the activities, services and products available on- <br /> site. <br /> This finding can be made because the proposed signs are located along <br /> the frontage of Hansen Road and along Interstate 580 and are located at <br /> access entrance points directing the public and employees to services and <br /> products available on-site. Although the project site is located along the <br /> Interstate 580 Scenic Route as identified in Figure VI-2 of the General Plan, <br />