Laserfiche WebLink
5,ENVIRONMENTAL CHECKLIST MOUNTAIN HOUSE NEIGHBORHOODS K AND L INITIAL STUDY <br /> 3,AIR QUALITY AND GREENHOUSE GAS EMISSIONS <br /> Table 5.3-4 SUMMARY OF PROJECT GREENHOUSE GAS EMISSIONS <br /> Percent <br /> Reduction <br /> Baseline Project Over <br /> Operational Category (MT CO2elyr)e (MT CO2etyr)h Baselines <br /> Area Sources 31.3 30.9 1.3% <br /> Energy Usage <br /> Residential <br /> Natural Gas 7,108 3,333 53% <br /> Electricity 7,355 5,015 32% <br /> Nan-Residential <br /> Natural Gas 382 179 53% <br /> Electricity 1,320 928 30%9 <br /> Mobile Sources 42,657 33,175 22% <br /> Solid Waste 1,027 1,027 0% <br /> Water 910 827 9.1% <br /> Swimming Pools 229 38 83% <br /> Total Before BPS Reductiond 61,019 44,552 27.0% <br /> BPS Percent Reductiond — -- 2.6% <br /> Total After BPS Reductiond 61,019 42,951 29.6% <br /> Vegetation(amortized)e -136 -136 0% <br /> Total with Vegetation 60,883 42,814 29.7% <br /> Notes: MT CO2e1yr=million tons of carbon dioxide equivalent per year,BPS=Best Performance <br /> Standards. <br /> a Baseline emissions for area sources,mobile sources,waste,and water are calculated by <br /> CalEEMod using 2005 as the modeled year.Baseline energy emissions for residential land use <br /> types are calculated using San Joaquin Valley Air Pollution Control District(SJVAPCD)baseline <br /> metrics for energy use,which are 2.88 MT CO201DUtyr for natural gas and 2.98 MT CO2e1DUiyr for <br /> electricity use(with"DU"representing a dwelling unit).The reduction achieved between this <br /> baseline metric and the project emissions is applied to non-residential land uses after removing the <br /> benefit for EnergyStar appliances from residential land uses.Baseline emissions here represent <br /> the project if it were built out in a business-as-usual manner.Additional methodology information <br /> and assumptions are detailed in Appendix C. <br /> n Project scenario represents emissions from the project in 2020. <br /> C Consistent with SJVAPCD guidance,the percentage reduction was calculated as the difference <br /> between the baseline and project emissions divided by the Baseline emissions. <br /> d Shea Homes has committed to incorporating BPS measures into the project.These are described <br /> in Mitigation Measure AIR-2 below. <br /> Vegetation sequestration numbers presented here have been amortized over 40 years.The <br /> project would result in a net increase in vegetation and sequestered carbon dioxide(CO2).This <br /> sequestration was not included in the 29 percent comparison,but is listed here for informational <br /> purposes only. <br /> Source:Environ,2011. <br /> (917I11) 5-44 <br />