Laserfiche WebLink
PA-0800005 Page 3 <br /> 30703 S. MacArthur Drive, Tracy <br /> (SWFP). According to the Environmental Health Department (EHD) records there was no <br /> SWFP issued for this facility in 1999. Provide clarification regarding this statement. <br /> K. The project description on page 23 of the RCSI indicates that the facility plans to use a CTI <br /> system composting operation as part of the expansion. This type of operation requires the <br /> use of blowers to aerate the compost. Provide design information and calculations for the <br /> CTI system. <br /> L. The Project Description proposes to increase traffic to 1727 vehicles per day. The project <br /> description did not reference or provide a traffic study to support the proposed numbers. <br /> M. The Biomass Gasification Unit proposes to use 40 TPD of processed clean wood waste to <br /> generate 1 mega-watt/hour of energy for on-site use. The EHD needs more information on <br /> construction and operation of the biomass gasification unit and on the operation of clean <br /> wood waste recovery from the mixed C&D processing facility. Proper evaluation for this <br /> facility from the San Joaquin Valley Air Pollution Control District is required. <br /> N. Expand the outdoor green waste processing operations to allow the processing of co- <br /> collected residential green waste with food waste, to produce compost feedstock and/or <br /> anaerobic digestion feedstock. The EHD will need more information on additional <br /> reasonable measures to minimize odors, including feedstock characteristics and quality, and <br /> OIMP. <br />