Laserfiche WebLink
/5.0 SOIL PROFILE INFORMATION SECTION: <br />L <br />-5-1 5.1 Site map showing location, with dimensions, of the soil profile pit on the parcel: See <br />Appendix. <br />/5.2 Description of soil profile pit including depth and dimensions: The shallow test holes <br />5 > were prepared per County Standards. The holes were excavated to a depth of approximately <br />36 inches and 8 inches in diameter. They were backfilled with 1-2 inches of "pea gravel." <br />The deep holes were prepared per County Standards. The deepholeereeddnl dot o a depth <br />approximately 22-24 feet. A 2 inch diameter PVC pipe with perforations on the bottom was <br />used to measure the drop of water in the percolation test boring. Approximately 1-2 inches of <br />"pea gravel" were placed in the bottom of test boring; the PVC was installed on top of the gravel. <br />about 6 inches of "Pea gravel' was placed in the annular space around the pipe. <br />5.3 Description of soil lithology as noted from test pit by appropriate professional using <br />industry standard protocol: The soil in this area is classified as Bruella sandy loam, San <br />Joaquin loam, Rocklin fine sandy loam, and Exeter sandy loam stated in the Soil Survey of San <br />Joaquin County, California as provided by the United States Department of Agriculture, Soil <br />` Conservation Service. <br />5.4 Discussion of soil lithology as related to future onsite septic uses: The aforementioned <br />soil types listed above have moderate to low permeability thus percolation rates varied as <br />demonstrated by the mixed results for all three parcels. (See Appendix). <br />., 6.0 PERCOLATION TEST INFORMATION SECTION <br />�.o <br />t/6.1 Site Map Showing the location, with concise and accurate dimensions of the percolation <br />.. test holes on the parcel: See Appendix. <br />6.2 The Minimum Number of Shallow and Deep Percolation Tests was Performed for Each <br />.. '� Parcel: Three shallow percolation test holes were prepared, one on each proposed parcel. Three <br />deep holes were also prepared due to the characteristics of the soil and the low permeability <br />rates. <br />6.3 Description of the Date, Time and Protocol Used to Prepare the Test Hole, Including <br />Depth and Dimensions of Hole, Preparation of Hole, and Depth of Water Used to Presoak <br />(Minimum 12 Inches): The shallow test holes were excavated to a depth of 36 inches and <br />8 inches in diameter and backfilled with1-2� s of "pea gravel' in accordance with County -----�1 <br />Standards. The shallow holes were prepared by staff of Neil O. Anderson & Associates on <br />January 26, 2006 and the 24 hour presoak period was started. The holes were filled with 12 <br />inches of water over the gravel and at this time. Environmental Health Department was notified <br />of the start of the test. <br />The deep holes were excavated to a depth of approximately 22-24 feet, respectively, and <br />backfilled with 1-2 inches of "pea gravel' in accordance with County Standards. <br />c:\0471\SoiI Report <br />