My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0007443 SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PELTIER
>
10020
>
2600 - Land Use Program
>
PA-0800323
>
SU0007443 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:33:04 AM
Creation date
9/8/2019 12:39:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0007443
PE
2622
FACILITY_NAME
PA-0800323
STREET_NUMBER
10020
Direction
W
STREET_NAME
PELTIER
STREET_TYPE
RD
City
THORNTON
APN
01106002
ENTERED_DATE
10/27/2008 12:00:00 AM
SITE_LOCATION
10020 W PELTIER RD
RECEIVED_DATE
10/27/2008 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\P\PELTIER\10020\PA-0800323\SU0007443\SS STDY.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
October 23, 2009 Page 5 of 10 <br /> Our Project Number: LGS0090518 <br /> A total of 23 soil borings were advanced on the Site, all to an approximate depth varying <br /> between 3.0 and 3.5 feet. The soil borings were used later for percolation test holes; the <br /> locations of the borings are indicated in Plate 1. The soil borings were approximately 3.5 feet, <br /> as noted above, and were four (4) inches in diameter. Generally, the soil encountered in the <br /> boring is similar to the soils reported by the San Joaquin County Soil Survey for the area (USDA, <br /> 1992). The table below presents the soil log for the soil boring. <br /> Table 2. <br /> Soil Boring Log. <br /> Depth Interval (ft) Soil Type Unified Soil Classification <br /> 0-3.5 Medium brown, sandy silt SM <br /> A visual inspection of the soils from on-site drilling indicates potential for percolation because of <br /> the nature of the soils. A percolation test is the best method to determine the suitability of the <br /> soils for a septic disposal area. Please see the next section for percolation test results. <br /> Generally speaking, coarser-grained soils have much greater potential for percolation than fine- <br /> grained or cemented soils. <br /> 5.0 PERCOLATION TEST INFORMATION <br /> A site map indicating the locations of the percolation test holes is included as Plate 1 in <br /> Appendix A of this report. One shallow percolation test was conducted on each of the 23 <br /> proposed parcels. The soil borings were advanced on the property with a hand auger. A 1.5- <br /> inch diameter PVC pipe with perforations on the bottom was used to measure the drop of water <br /> in the percolation test boring. Approximately two (2) inches of "pea gravel' was placed in the <br /> bottom of the open soil boring and then the PVC pipe was installed on top of the gravel. "Pea <br /> gravel' was then used to backfill in the annular space. Presaturation of the percolation test <br /> holes occurred approximately 24 hours prior to the day of testing. The depth of water used to <br /> pre-soak was 12 inches above the bottom of the boring. After the 24-hour soak period, the <br /> presaturated holes were found to be intact and dry on the day of testing. <br /> 5.1 Percolation Test Procedure <br /> Percolation tests were conducted for the borings on August 10, 12, 13, 28, and September 29 <br /> of 2009 in accordance with the requirements of the EHD. A four (4) hour percolation test was <br /> performed for the test. The last half an hour of the test was observed by either Michael Escotto <br /> or Lisa Medina (depending on date), both Senior Registered Environmental Health Specialists, at <br /> EHD. <br /> Measurement of the water level during the percolation test was from a fixed reference point on <br /> the PVC casing using an electric well sounder with a depth accuracy of 1/100th foot. All <br /> tabulated values on the field data sheet are in decimal feet. After water drop was observed, <br /> the holes were checked for refill. The refill level was approximately 0.5 ft (6 inches) of water <br /> above the bottom level of the percolation test hole. The readings were taken every 30 minutes <br /> for a period of four (4) hours. <br /> '44 <br /> 902 Industrial Way•Lodi,CA 95240-209.367.3701 •Fax 209.369.4228 02009 Neil 0.Anderson&Associates,Im <br />
The URL can be used to link to this page
Your browser does not support the video tag.