My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0012042
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WOODBRIDGE
>
5573
>
2600 - Land Use Program
>
PA-1800279
>
SU0012042
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/7/2020 11:35:37 AM
Creation date
9/9/2019 11:11:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0012042
PE
2626
FACILITY_NAME
PA-1800279
STREET_NUMBER
5573
Direction
W
STREET_NAME
WOODBRIDGE
STREET_TYPE
RD
City
LODI
Zip
95242-
APN
01117052
ENTERED_DATE
10/30/2018 12:00:00 AM
SITE_LOCATION
5573 W WOODBRIDGE RD
RECEIVED_DATE
11/13/2018 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
TSok
Supplemental fields
FilePath
\MIGRATIONS\W\WOODBRIDGE\5573\PA-1800279\SU0012042\APPL.PDF \MIGRATIONS\W\WOODBRIDGE\5573\PA-1800279\SU0012042\EHD COND.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
87
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The applicant submitted a parking modification request in the application dated October 18, <br /> 2018 to reduce the number of parking spaces from twenty-five (25) to eleven(11) parking <br /> spaces for Phase One(1)of the project,and from 237 parking spaces to a total of 70 parking <br /> spaces at full buildout. The applicant states that many of the proposed and existing <br /> structures are utilized for storage only.The applicant also states that the maximum number <br /> of employees anticipated on site at any time is twelve (12) and the number of attendees for <br /> the marketing events will be fifty (50). The Community Development Department has <br /> reviewed the request and has determined that a reduction in the number of parking spaces <br /> to eleven (11) parking spaces during Phase One (1)-and seventy(70) parking spaces at full <br /> buildout is sufficient for the proposed winery expansion. As a result, as a Condition of <br /> Approval, the applicant shall provide eleven (11) parking spaces for Phase One (1),,twenty- <br /> five(25) parking spaces for Phase Two (2), twelve (12) parking spaces for Phase Three (3), <br /> eleven (11) parking spaces for Phase four (4), and Eleven (11) parking spaces for Phase <br /> Five (5) of development. As a result, seventy (70) parking spaces will be provided at full <br /> buildout. <br /> The site plan depicts the proposed parking stall dimensions to be ten (10) feet wide by <br /> eight-teen (�8) feet long. Pursuant to Development Title Section 9-1015.5 (b)(1), each <br /> parking stall shall be an unobstructed rectangle, minimum of nine (9) feet wide by twenty <br /> (20)feet long, except for parallel stalls,which must be nine (9)feet wide by twenty-six(26) <br /> feet long. The required parking stall dimensions shall be depicted on a revised site plan. <br /> Surfacing <br /> The proposed site plan depicts gravel surface material for the proposed parking and <br /> circulation area for the winery operation Pursuant to Development Title Section 9- <br /> 1015.5(e), all parking and maneuvering areas, ingress, and egress areas that connect to <br /> a paved road must be surfaced and permanently maintained with asphalt concrete or <br /> portland cement concrete to provide a durable dust free surface. The applicant shall <br /> submit a revised site plan depicting the required surfacing material. <br /> Access and Circulation <br /> The site plan depicts the width of the proposed driveways thirteen (1.3) feet, however the <br /> site plan contains a note stating the driveway will be improved to fire road standards, a <br /> minimum of twenty (20) feet in width. Pursuant to Development Title Section 9- <br /> 1015.5(h)(1), access driveways shall have a width of no less than twenty-five (25)feet for <br /> two-way aisles and sixteen (16) feet for one-way aisles except that in no case shall <br /> driveways designated as fire department access be less than twenty (20) feet wide. As a <br /> result, the proposed winery will be conditioned to install a minimum twenty-five (25) foot <br /> access driveway. This must me depicted be depicted on the Improvement-Plan. <br /> Lighting <br /> The applicant states that the hours of operation for the Marketing Events will be limited to <br /> 9:00 PM. Pursuant to Development Title Section 9-1015.5(8)(4), parking lot and security <br /> lighting must be installed if parking area is to be used at night and all lighting must be <br /> designed to confine direct rays to the premises with no spill over. The site plan does not <br /> depict lighting for the parking area. The required lighting must be depicted on the <br /> Improvement Plan. <br /> Landscaping <br /> The Site Plan does not depict any landscaping. Pursuant to Development Title Section 9- <br /> 1020.5(c), a minimum ten(10)foot wide landscaped strip shall be installed between parking <br /> 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.