Laserfiche WebLink
Phase I Environmental Site Assessment <br /> No listings are found in the EDR report for sites within the ASTM approximate search distances from the <br /> Site for the following databases: <br /> • Federal NPL,Proposed NPL,and Delisted NPL <br /> • Federal CERCLIS <br /> • Federal CORRACTS <br /> • Federal RCRA <br /> • Federal ERNS <br /> • California CHMIRS <br /> • California CORTESE <br /> • California LUST <br /> • California NOTIFY 65 <br /> • California AWP(BEP) <br /> • California Cal-Sites <br /> • California SLIC <br /> • California SWF/LF <br /> • California Toxic Pits <br /> • California WMUDS/SWAT <br /> • California UST <br /> • California AST <br /> • California HAZNET <br /> • CA WDS <br /> The EDR Report listed no sites that lie within the ASTM approximate search distances from the Site for <br /> the searched databases with the exception of the adjacent NCPA facility(the facility's address was used <br /> as the Site locator,and the EDR report lists the existing power plant as the target property). The adjacent <br /> site was found to be listed on two databases;the ICIS and FINDS databases. No incidents or processes <br /> were identified in the database reports indicating hazardous materials or petroleum product impacts to <br /> the Site soil or groundwater. <br /> The agency lists searched by EDR are included on the Map Findings Summary on pages 4 and 5 of the <br /> Radius Map report. An explanation of government records abbreviations is found beginning on page GR- <br /> 1 of the EDR Radius Map report,included in the Appendix of this report. <br /> 5.2.2 Oil and Gas Wells <br /> EDR searched records from the California Department of Conservation Division of Oil and Gas for oil and <br /> gas well locations in the area. EDR found four entries indicating the existence of oil/gas wells or <br /> exploration wells(or other categories of wells)within approximately one mile of the Site. The closest <br /> well to the Site is reported as an injection well operated by the NCPA. <br /> 5.2.3 Radon Information <br /> EDR reports that the Site is located in Federal EPA Radon Zone 3. Federal database information indicates <br /> that 20 sites have been tested for radon in the San Joaquin County area. Average activity for 2nd floor areas <br /> is not reported;average activity for 1"floor areas is reported as 2.530 pCi/L,and average activity for <br /> basement areas is reported as 2.050 pCi/L. State database information indicates 7 sites have been tested <br /> for radon in the San Joaquin County area,and 3 of the sites had test results greater than 4 pCi/L. Radon <br /> Levels above 4 pCi/L indicate testing should be considered for basement space design considerations. <br /> 5.2.4 FEMA Flood Information <br /> EDR also reports flood zone information obtained from the Federal Emergency Management Agency <br /> (FEMA),if found. According to the data provided in the EDR report,the Site lies within a FEMA <br /> designated 100-year flood-zone. However,a civil engineer should confirm the flood zone designation. <br /> Lodi Energy Center Property ESA 9 <br /> Carlton Project No.6300-01-08 <br /> June 2008 <br /> CARLTON <br /> IM <br /> E n g i n e e r i n g I n c. <br />