Laserfiche WebLink
Of <br />0 <br />Z <br />Q <br />c� <br />Z <br />iY <br />Lu <br />Lu <br />Z <br />0 <br />Z <br />Lu <br />GENERAL NOTES <br />PLUMBING GENERAL NOTES <br />PLUMBING GENERAL NOTES CON'T. <br />LEGENDS, SYMBOLS AND ABBREVIATIONS <br />1. <br />CONTRACTOR SHALL VISIT JOB SITE, VERIFY FIELD CONDITIONS, REVIEW <br />14. <br />PIPING SHALL BE NEW AND FREE FROM FOREIGN SUBSTANCES. REAM <br />36. SANITARY AND GREASE DRAINAGE PIPING AND FITTING: <br />SYMBOL DESCRIPTION <br />7 <br />PLAN AND SPECIFICATIONS AND SHALL INCLUDE IN HIS PRICE THE <br />OUT ALL BURRS FORMED IN CUTTING PIPE. THREADS SHALL BE CUT <br />NECESSARY COST TO CONSTRUCT THIS PROJECT IN ACCORDANCE WITH THE <br />ACCURATELY AND NOT OVER TWO THREADS SHALL SHOW BEYOND THE <br />A. CAST IRON SOIL PIPE AND FITTINGS (ABOVE FLOOR): REQUIRED <br />MECHANICAL DRAWING AND SHALL MEET ALL APPLICABLE CODES. <br />FITTING. FRICTION WRENCHES SHALL BE USED WITH PLATED POLISHED, <br />CISPI 301 & 310 WHICH COMPLIANCE WITH HUD UM 77A CAST IRON <br />UP EQUIPMENT TYPE <br />OR SOFT METAL PIPING. <br />HUBLESS SOIL PIPE AND FITTING. ALL PIPE AND FITTINGS SHALL BE <br />LO EQUIPMENT NUMBER <br />2. <br />ALL MATERIAL AND EQUIPMENT FURNISHED AND INSTALLED SHALL BE NEW, <br />MARKED WITH CISPI'S COLLECTIVE TRADEMARK OR RECEIVE PRIOR <br />DETAIL DRAWING NUMBER <br />� r� <br />JHP <br />FREE FROM DEFECTS AND SHALL BE GUARANTEED FOR A PERIOD OF ONE <br />15. <br />CHANGES IN PIPE SIZE SHALL BE MADE WITH REDUCING FITTINGS, AND <br />APPROVAL BE THE ENGINEER OF RECORD. JOINTS FOR HUBLESS PIPE <br />M-� DETAIL DRAWING PAGE <br />Ez'L� PP <br />►gl <br />YEAR FROM DATE OF FINAL ACCEPTANCE BY THE OWNER. SHOULD ANY <br />BUSHING WILL NOT BE PERMITTED. <br />AND FITTINGS: CISPI 310 AND SHALL CONFORM TO THE <br />�� ■1-7 <br />JJ J'J`J�JJJ <br />TROUBLE DEVELOP DURING THE PERIOD DUE TO FAULTY WORKMANSHIP OR <br />MANUFACTURERS INSTALLATION INSTRUCTIONS AND LOCAL CODE <br />�� POC POINT OF CONNECTION <br />aJJJ-� �e'a1�J <br />MATERIAL, THE CONTRACTOR SHALL FURNISH ALL NECESSARY MATERIAL <br />16. <br />UNION CONNECTION SHALL BE INSTALLED DOWNSTREAM OF ALL VALVES, <br />SJgr�V1Cye�Sj Irn-1 rm <br />AND LABOR TO CORRECT THE TROUBLE WITHOUT COST TO THE OWNER. <br />AT ALL EQUIPMENT CONNECTIONS AND AT OTHER POINTS AS REQUIRED. <br />REQUIREMENTS. ANACO HUSKY SD 4000, CLAMP-ALL 125, TYLER <br />�� POD POINT OF DISCONNECT <br />WB, MG COUPLINGS, OR EQUAL, COMPLY WITH FM 1680, CLASS 1. <br />ADR: 3119 Central Parkway, <br />3. <br />CONTRACTOR IS TO REVIEW THE PLANS OF OTHER DISCIPLINES AND <br />17. <br />CUTTING OR BORING OF HOLES THROUGH STRUCTURAL MEMBERS SHALL <br />B. CAST IRON SOIL PIPE AND FITTINGS (BELOW SLAB): ASTM A74 <br />' -- PLUMBING FIXTURE CONNECTION <br />TEL: 551011788 6 249568 <br />COORDINATE WITH THE WORK OF OTHER TRADES PRIOR TO INSTALLATION <br />BE DONE ONLY WHEN IT IS IMPOSSIBLE TO ROUTE PIPING IN ANOTHER <br />STANDARD WEIGHT HUB AND SPIGOT PIPING AND FITTING. ALL PIPE <br />= CO CLEAN OUT <br />CEL: 510-468-0613 <br />FAX: 510-788-6039 <br />TO AVOID ANY CONFLICT BETWEEN DUCTS, CONDUITS, SPRINKLERS, PIPING, <br />MANNER. IF CUTTING OR BORING IS NECESSARY IT SHALL BE <br />AND FITTINGS SHALL BE MARKED WITH CISPI'S COLLECTIVE <br />LIGHTING FIXTURES, ETC. NO EXTRAS WILL BE ALLOWED FOR CORRECTION <br />ACCOMPLISHED ONLY BY WRITTEN APPROVAL FROM THE ARCHITECT, <br />TRADEMARK OR RECEIVE PRIOR APPROVAL BE THE ENGINEER OF <br />DN. PIPE DOWN <br />RpFESS/0 <br />OF CONFLICTS DUE TO LACK OF COORDINATION. <br />STRUCTURAL AND BUILDING ENGINEER, AND ALSO INCLUDED IN HIS BIDS <br />RECORD. JOINT FOR HUB AND SPIGOT PIPE AND FITTINGS: ASTM <br />0- UP PIPE UP <br />roe Nu <br />WORK SHALL COMPLY WITH CBC SECTIONS 2320A.8.3 AND 2320A.11.10. <br />C-564 COMPRESSION GASKETS OR SHALL BE INSTALLED WITH LEAD <br />> -- FLOW DIRECTION <br />4. <br />THE DRAWINGS ARE DIAGRAMMATIC AND SHALL NOT BE SCALED TO <br />AND OAKUM. <br />M3 <br />DETERMINE EXACT LOCATION OF PIPING, DUCT WORK OR DIFFUSERS. <br />18. <br />DO NOT ALLOW THE PIPING, VALVES OR CONNECTORS TO FORM A RIGID <br />C. COPPER DRAINAGE PIPING AND FITTINGS (ABOVE FLOOR): ASTM <br />J TP TRAP PRIMER W/ WALL ACCESS PANEL <br />E=H_.,6/31/19 <br />CONNECTION WITH THE STRUCTURE OR OTHER PIPES. INSTALL PIPING TO <br />COPPER AND B16.23 CAST BRONZE <br />SOV SHUT-OFF VALVE <br />5. <br />THE CONTRACTOR SHALL BRING TO THE ARCHITECTS ATTENTION OF ANY <br />ALLOW FOR EXPANSION AND CONTRACTION WITHOUT STRESSING PIPE, <br />SOLDER-JOINT OINTPE <br />DRAINAGE TYPEG <br />FITTING. MISSION, OR <br />N CKV CHECK VALVE <br />q <br />° <br />DISCREPANCY OR CONFLICTS IN THE PLANS OR THE SITE CONDITIONS. ALL <br />JOINTS OR CONNECTED EQUIPMENT. <br />EQUAL, CISPI 310 ADAPTOR COUPLING WITH NEOPRENE GASKET AND <br />NECESSARY CHANGES MUST BE APPROVED IN WRITING BY THE ARCHITECT <br />STAINLESS STEEL SHIELD WITH TWO BANDS. <br />r�i GCK GAS COCK <br />BEFORE START OR WORK. <br />19. <br />PROVIDE SIOUX CHIEF WATER HAMMER ARRESTER FOR EACH PLUMBING <br />D. CONDENSATE PIPING AND FITTINGS: ASTM B88 HARD DRAWN <br />® FD FLOOR DRAIN <br />FIXTURE BANK OR 18" HIGH AIR CHAMBER FOR EACH PLUMBING <br />DEOXIDIZED, TYPE M COPPER TUBING WITH ANSI B16.22 WROUGHT <br />Revisions Date <br />6. <br />CONTRACTOR TO SUBMIT CATALOG CUT SHEETS OF ALL THE MATERIAL <br />FIXTURE. SIZE OF WATER HAMMER ARRESTER SHALL BE SUFFICIENT TO <br />COPPER WYES AND LONG RADIUS SOLDER-JOINT FITTINGS. <br />► PR PIPE REDUCER <br />PROGRESS REVIEW 10-01-2018 <br />AND EQUIPMENT TO BE USED AND WORKING SHOP DRAWINGS FOR <br />HANDLE THE REQUIRED FIXTURE UNIT AT EACH BANK. <br />s WCO WALL CLEAN-OUT <br />APPROVAL BEFORE START OF WORK. <br />37. NATURAL GAS PIPING AND FITTING: <br />PERMIT SET 10-29-2018 <br />20. <br />THE DOMESTIC WATER SUPPLY AND DISTRIBUTION SYSTEM WITHIN THE <br />FCO FLOOR CLEAN-OUT <br />7. <br />SUPPORTS FOR ALL PIPING AND DUCTWORK SHALL BE IN ACCORDANCE <br />AREA OF WORK SHALL BE STERILIZED WITH CHLORINE IN SOLUTION IN <br />A. BELOW GRADE PIPING: SCHEDULE 40 STEEL PIPE WITH DRESSERS <br />BDV STRAINER WITH BLOWDOWN VALVE <br />WITH LATEST SMACNA "GUIDELINES FOR SEISMIC RESTRAINTS OR <br />ACCORDANCE WITH AMERICAN WATER WORKS ASSOCIATION PUBLICATION <br />TYPE AND STEEL WELDING FITTINGS. PRE-WRAP WITH MILL-WRAPPED <br />MECHANICAL SYSTEMS AND PLUMBING SYSTEMS". <br />C-601-1954. <br />CORROSION PROTECTION EXTRUDED POLYOLEFIN COATING IN <br />101 SMV SEISMIC SHUT-OFF VALVE <br />ACCORDANCE WITH GAS COMPANY REQUIRMENTS. OR HIGH DENSITY <br />21. <br />PRESSURE TEST ENTIRE HOT AND COLD PIPING AND DRAINAGE SYSTEM <br />POLYETHYLENE PIPING CONFORMING WITH ASTM D 2513, WITH <br />TMR WATER TEMPERATURE THERMOMETER <br />Preliminary set <br />PLUMBING GENERAL NOTES <br />FROM CAPPED CONNECTIONS, TO AND INCLUDING VENTS. <br />SOCKET TYPE FITTINGS CONFORMING WITH ASTM D 2683, AND <br />MINIMUM SDR 11. FOR 6" SIZE OR LARGER NATURAL GAS MAIN, <br />LINE TYPE ABBREV. DESCRIPTION <br />Design Review Set <br />Plan Check Set x <br />1. PROVIDE ISOLATED COUPLINGS AND/OR UNIONS AT POINTS OF <br />22• <br />HOT WATER PIPING TO BE INSULATED PER CODE. <br />USE BUTT FITTINGS WITH SDR 1 1 . PROVIDE POLYETHYLENE TO SCH. <br />Plan Check Resubmit <br />CONNECTION BETWEEN COPPER, STEEL AND BRASS PIPING. <br />40 STEEL PIPE TRANSITION FITTING AND RISER AT EACH BUILDING <br />(D) PIPE TO BE REMOVED <br />23• <br />PROVIDE ACCESS PANEL FOR ALL STUB OUTS ENDED INSIDE CEILING OR <br />PRIOR TO EXTENDING GAS PIPING ABOVE GROUND. PROVIDE 16 AWG <br />Construction Set <br />2. <br />ALL WATER PIPING SYSTEMS AND DRAINAGE PIPING SYSTEMS, INCLUDING <br />WALL. <br />COPPER TRACE WIRE OVER ENTIRE RUN OF PE PIPING AT 12 INCHES <br />E EXISTING PIPE TO REMAIN <br />( ) <br />SUPPLY, WASTE AND DRAIN SHALL BE INSTALLED WITH VIBRATION <br />ABOVE PIPE. <br />G G. NATURAL GAS <br />ISOLATORS AND SHALL BE ISOLATED FROM ANY STRUCTURAL MEMBERS, <br />24. <br />THREADED FITTINGS: ANSI/ASME B16.3 BLACK MALLEABLE IRON. <br />B. FOR ABOVE GRADE PIPING: ASTM A-53, SCHEDULE 40 BLACK STEEL <br />WALL SECTIONS OR OTHER MATERIALS THAT COULD TRANSMIT SOUND TO <br />PIPING WITH MALLEABLE IRON THREADED FITTING CONFORMING TO <br />HWS- HWS HOT WATER SUPPLY <br />THE OCCUPIED AREAS. ALL HANGERS, STRAPS, BRACKETS, AND SUPPORTS <br />25. <br />SOCKET-WELDING FITTINGS: ANSI B16.11 FORGED STEEL. <br />ANSI B16.3, AND SCHEDULE 40 STEEL FITTING FOR BUTT WELDING <br />�HWR HWR HOT WATER RETURN <br />SHALL HAVE ACOUSTICAL COMPONENTS OR COMBINED NEOPRENE AND <br />CONFORMING TO ASTM A234, OR ASME B16.9 <br />PLASTIC FOAM BY TECH SPECIALTIES, DIVISION OF SPECIALTY PRODUCTS <br />CW CW COLD WATER SUPPLY <br />CO. TO ISOLATE COMPLETE PIPE CONTACT AREA. ALL ISOLATION MATERIAL <br />26. <br />BUTT-WELDING FITTINGS: ANSI 81 6.9 WROUGHT STEEL WITH <br />ASME <br />38 ALL FIXTURES EQUIPMENT PIPING AND MATERIALS SHALL BE LISTED. <br />SW SW SANITARY WASTE <br />SHALL HAVE A MINIMUM THICKNESS OF 1/2". INSTALL ALL COMPONENTS <br />BACKING RINGS OF COMPATIBLEEMATERIAL. <br />AS PER MANUFACTURER'S INSTRUCTIONS. <br />27. <br />UNIONS: ASME/ANSI B16.39 BLACK MALLEABLE IRON. <br />39. ALL FAUCETS IN PUBLIC RESTROOMS SHALL BE SELF-CLOSING OR <br />GW GW GREASE WASTE <br />SELF-CLOSING METERING FAUCETS. <br />- - V VENT PIPE <br />3. <br />INSTALL ALL CLEAN-OUTS WHERE REQUIRED BY ORDINANCES, AT ENDS <br />OF HOUSE DRAINS, AT ALL CHANGES IN DIRECTIONS, IN ALL STRAIGHT <br />28. <br />FLANGES AND FLANGED FITTINGS: ASME/ANSI 816.5 STEEL FLANGES OR <br />40. PUBLIC LAVATORIES SHALL HAVE CONTROLS TO LIMIT THE WATER <br />CD CD CONDENSATE DRAIN <br />RUNS AT 100 FOOT INTERVALS, WHERE HORIZONTAL MAINS CHANGE SIZE, <br />CONVOLUTED STEEL FLANGES. FLANGE FACES SHALL HAVE INTEGRAL <br />TEMPERATURE TO 105°F. <br />AND AT ALL ENDS OF ALL BRANCH PIPES WHICH ARE 5' OR OVER IN <br />GROOVES OF RECTANGULAR CROSS SECTION WHICH AFFORD <br />BFP BACK-FLOW PREVENTER <br />O <br />LENGTH. <br />CONTAINMENT FOR SELF-ENERGIZING GASKET MATERIAL. <br />41. WATER PIPE AND FITTINGS WITH A LEAD CONTENT WITH EXCEEDS 8% <br />4. <br />PLUMBING FIXTURES SHALL BE COMPLETED WITH ALL ACCESSORIES <br />29. <br />THREADED JOINTS: WHERE POSSIBLE USE PIPE WITH FACTORY-CUT THREADS, <br />SHALL BE PROHIBITED IN SYSTEMS CONVEYING POTABLE WATER. <br />ABBR. DESCRIPTION ABBR. DESCRIPTION <br />REQUIRED FOR A COMPLETE INSTALLATION. <br />OTHERWISE CUT PIPE LENGTHS ACCORDINGLY WITH ANSI/ASME B1.20.1. <br />�e <br />PROVIDE THREADS SMOOTH, CLEAN, AND FULL-CUT. APPLY ANTI-SEIZE PASTE <br />42. ALL NATURAL GAS COOKING EQUIPMENT SHALL BE EQUIPPED WITH QUICK <br />AFF ABOVE FINISHED FLOOR FR FROM <br />5. <br />SELECTION OF FAUCETS AND FITTINGS SHALL AVOID THE TYPE WITH <br />OR TAPE TO MALE THREADS PORTION. WORK PIPING INTO PLACE WITHOUT <br />DISCONNECT GAS HOSE CONNECTION AND RESTRAINING CABLE ATTACHED <br />V <br />POTENTIAL FOR LEAD CONTAMINATION. <br />SPRINGING OR FORCING. BACKING OFF TO PERMIT ALIGNMENT OF THREADED <br />TO THE EQUIPMENT. <br />BLDG BUILDING GE GREASE EXHAUST <br />JOINTS WILL NOT BE PERMITTED. ENGAGE THREADS SO THAT NOT MORE THAN <br />BSMT BASEMENT <br />O <br />DRAWING INDEX <br />6. INSTALL STOP VALVES ON HOT AND COLD WATER SUPPLIES TO EACH <br />TWO THREADS REMAIN EXPOSED. USE UNIONS FOR CONNECTIONS TO VALVES, <br />ICS IN CEILING SPACE <br />FIXTURE. <br />METERS FOR WHICH A MEANS OF DISCONNECTION IS NOT OTHERWISE <br />CFF CAP FOR FUTURE INSINSULATION THERMAL <br />(THERMAL) <br />PROVIDED. <br />PB-0.1 PLUMBING NOTES AND GENERAL INFORMATION <br />CLG CEILING <br />7. <br />ALL FLOOR DRAIN MUST HAVE 1/2" COLD WATER LINE CONNECTED TO <br />30. <br />WELDED JOINTS: WELD BY THE SHIELDED METAL-ARC PROCESS, USING <br />PB-0.2 PLUMBING SCHEDULES, CALCULATION, AND TABLES <br />CSD CEILING SUPPLY DIFFUSER NIC NOT IN CONTRACT <br />TRAP PRIMER. ALL UNDERGROUND COLD WATER LINE SHALL BE ASTM <br />COVERED ELECTRODES AND IN ACCORDANCE WITH PROCEDURES ESTABLISHED <br />PB-0.3 PLUMBING DETAILS <br />TYPE-K HARD DRAWN COOPER INSTALLED WITH CONTINUOUS SLOPE <br />AND QUALIFIED IN ACCORDANCE WITH ASME B31.8. <br />PB-0.4 PLUMBING DETAILS <br />EA EXHAUST AIR OSA OUTSIDE AIR (FRESH AIR) <br />1 <br />TOWARD FLOOR DRAIN. <br />31. <br />FLANGED JOINTS: USE FLANGED JOINTS FOR CONNECTING WELDED JOINT PIPE <br />PB-1.0 GROUND FLOOR DOMESTIC WATER PIPING PLAN <br />DN DOWN SA SUPPLY AIRI <br />PB-1.1 GROUND FLOOR WASTE AND VENT PIPING PLAN <br />8. <br />MATERIALS, METHODS AND LOCATIONS OF SERVICE MAINS CONNECTING <br />AND FITTINGS TO VALVES TO PROVIDE FOR DISCONNECTION. INSTALL JOINTS <br />PB-1.2 GROUND FLOOR GAS PIPING PLAN <br />SAD SEE ARCHITECTURAL DRAWING <br />>. <br />THE NEW CONSTRUCTION TO ALL NEW AND EXISTING SERVICES SHALL BE <br />SO THAT FLANGE FACES BEAR UNIFORMLY ON GASKETS. ENGAGE BOLTS SO <br />FA FRESH AIR SOV SHUT-OFF VALVE <br />IN STRICT ACCORDANCE WITH RULES, REGULATIONS, CODES AND <br />THAT THERE IF COMPLETE THREADING THROUGH THE NUTS AND TIGHTEN SO <br />PB-2.0 ROOF PLUMBING PLAN <br />SRR SIDEWALL RETURN REGISTER <br />U)REQUIREMENTS <br />OF ALL AGENCIES HAVING JURISDICTION OVER THIS <br />THAT BOLTS ARE UNIFORMLY STRESSED AND EQUALLY TORQUE. <br />FL FLOOR <br />F--- O� <br />INSTALLATION. LOCATE ALL EXISTING STUBS TO BE CONNECTED TO IN <br />FR FROM UTR UP THROUGH ROOF <br />LU C) <br />LZLI O� <br />SCOPE OF WORK <br />THIS CONTRACT BEFORE WORK IS STARTED. COORDINATE LOCATION OF <br />32. <br />USE TEST PRESSURE OF 50 PSIG. DO NOT TEST UNTIL EVERY JOINT HAS SET <br />CV <br />WATER AND SEWER CONNECTIONS WITH BUILDING ENGINEER. <br />AND COOLED AT LEAST 8 HOURS AT TEMPERATURES ABOVE 50 DEGREES F. <br />VTF VENT THROUGH ROOF <br />J <br />0-) <br />LLJ <br />TEST PIPING SYSTEM FOR AT LEAST 4 HOURS WITHOUT PRESSURE LOSS OR <br />0 FURNISH AND INSTALL NATURAL GAS PIPING SYSTEM AND ALL OTHER <br />O <br />9. <br />CAULK AIRTIGHT ALL PLUMBING PENETRATIONS IN SOUND RATED WALLS <br />VISIBLE LEAKS. <br />ASSOCIATED COMPONENTS PER PLAN. <br />O z Q <br />AND FLOOR/CEILINGS. SEAL PENETRATIONS OF CONCRETE FLOORS WITH <br />33. <br />PLUMBING FIXTURE CONNECTION SIZE: SEE PLAN.FURNISH <br />0 U <br />- <br />CEMENT GROUT. MINIMIZE PENETRATIONS THROUGH SOUND RATED <br />AND INSTALL PLUMBING FIXTURES AND ASSOCIATED COMPONENTS <br />CONSTRUCTION. <br />34. <br />ALL HOT WATER PIPE SHALL BE INSULATED WITH INSULATION PER 2016 <br />PER PLAN. <br />Q Z <br />TITLE 24 STANDARD. MINIMUM 1 "-THICK INSULATION FOR PIPE LESS <br />0 FURNISH AND INSTALL NEW DOMESTIC WATER PIPING SYSTEM WITH ALL <br />V Z O <br />10. <br />CONTRACTOR SHALL INSTALL ALL PLUMBING FIXTURES AND TRIM AS <br />THAN 1 "0 AND MINIMUM 1Y2"-THICK INSULATION FOR PIPE LARGER THAN <br />OTHER ASSOCIATED COMPONENTS PER PLAN. <br />0 <br />� <br />SHOWN ON THE ARCHITECTURAL PLANS. ROUGH-IN FOR ALL FIXTURES <br />"0. <br />Q U <br />SHALL BE EXACTLY TO MEASUREMENTS FURNISHED BY FIXTURE <br />OR EQUAL TO 1 <br />0 FURNISH AND INSTALL NEW WASTE, GREASE WASTE, AND VENT SYSTEM <br />to <br />W Lo 0 <br />MANUFACTURER. ALL EXPOSED PARTS TO BE CHROMIUM PLATED UNLESS <br />WITH ALL OTHER ASSOCIATED COMPONENT PER PLAN. <br />� <br />SPECIFIED OTHERWISE. <br />35. <br />PRESSURE PIPING AND FITTING: <br />F--- <br />1 1 . <br />KEEP ROUGH-IN CUTS WITHIN THE PLATE LINES AND DO NOT CUT <br />A. DOMESTIC COLD AND HOT WATER (ABOVE GRADE): HARD DRAWN <br />APPLICABLE CODE <br />COMPLETELY THROUGH PLATES IN SOUND-RATED WALLS. DRILL OR SAW <br />DEOXIDIZED WATER SERVICE TUBING CONFORMING TO ASTM B88, <br />NEAT ROUND HOLES FOR ALL PIPING. SIZE APPROXIMATELY Y2 INCH <br />TYPE "L". PROVIDE 125 PSI FLANGE AT CHANGE OF MATERIAL <br />2016 CALIFORNIA BUILDING CODE <br />LARGER THAN THE PIPE DIAMETER. <br />LOCATIONS. <br />2016 CALIFORNIA MECHANICAL CODE <br />Scale: AS NOTED <br />B. DOMESTIC COLD AND HOT WATER (BELOW GRADE): HARD DRAWN <br />2016 CALIFORNIA PLUMBING CODE <br />12. <br />PIPE LINES SHALL BE INSTALLED FREE FROM TRAPS AND AIR POCKETS <br />DEOXIDIZED WATER SERVICE TUBING CONFORMING TO ASTM B88, <br />2016 CALIFORNIA ENERGY CODE <br />Drawn By: AL <br />AND TRUE TO LINE AND GRADE WITH SUITABLE SUPPORTS PROPERLY <br />TYPE TYPE "K". <br />2016 CALIFORNIA FIRE CODE <br />Approved By: JP <br />SPACED. PIPING SHALL BE INSTALLED WITHOUT UNDUE STRESSES AND <br />C. FITTINGS FOR COPPER WATER TUBING: ANSI B16.22 WROUGHT <br />2016 CALIFORNIA GREEN BUILDING CODE <br />WITH PROVISION FOR EXPANSION AND CONTRACTIONS. <br />COPPER SOLDER-JOINT FITTING. <br />2016 NEPA 13 <br />Job: 18033 <br />D. TRAP PRIMER PIPING (UNDERGROUND): HARD DRAWN DEOXIDIZED <br />ALL AMENDMENTS AND SUPPLEMENTS TO ABOVE CODES <br />13. <br />HORIZONTAL LINES SHALL HAVE HANGERS OR SUPPORTS SPACED AS <br />WATER SERVICE TUBING CONFORMING TO ASTM B88, TYPE "K", <br />ALL CITY OF STOCKTON ORDINANCES AND AMENDMENTS TO ABOVE CODES <br />Sheet: <br />FOLLOWS: <br />WROUGHT COPPER FITTING AND BRAZED JOINT. <br />PLUMBING NOTES <br />E. HARRIS, ENGELHARD, OR EQUAL, BCUP FILLER MATERIAL FOR <br />AND GENERAL <br />A. CAST IRON PIPE - 5' CENTERS <br />BRAZING OF COPPER FITTING JOINTS. BRAZE JOINTS FOR COLD <br />B. STEEL PIPE - 10' CENTERS <br />WATER PIPING 2-1/2" AND LARGER. BRAZE JOINTS FOR HOT <br />INFORMATION <br />C. COOPER TUBING - 5' CENTERS FOR 1-1/2" AND SMALLER, 10' <br />WATER PIPING 2-1/2" AND LARGER. <br />of: PB=Oml <br />CENTERS FOR 2" AND LARGER <br />