9 NPT threaded Thread preparation <br /> connections Inspect threads on fiberglass adapters and threaded bushings. <br /> Do not use if threads are damaged. <br /> • Inspect threads on steel fittings for burrs. <br /> • Remove burrs from steel fittings by making up to mating steel threads.Unmake <br /> the steel fitting and reinspect. <br /> • Always dry fit fiberglass and steel threads without sealing compound.It should be <br /> r———————————, possible to dry fit the threads as shown in the following table.If the proper <br /> On bell x female adapters,use I number of threads cannot be made up,select a new steel fitting. <br /> pipe wrench over threaded <br /> portion only.On bell x male Making the joint <br /> adapters,use pipe wrench on <br /> steel nipple whenever possible. Threads must be clean and dry before applying thread-sealing compound. <br /> • Use a nonhardening,solvent-free Teflon based thread sealant such as Jomar <br /> L———————————J Seal"The Heavyweight"or Gasoila Soft Set pipe sealant. <br /> r___________, Apply sealing compound to male and female threads. <br /> I In general,threaded connections I • Hand tighten the joint,then <br /> should be made up before I use a wrench to get full <br /> adhesive-bonded joints to I make-up.Standard pipe Threads to Dry Fit and to Seal <br /> minimize the possibility of I <br /> wrenches can be used with Nominal <br /> care on fiber lass ada ters. <br /> damage to bonded joints caused I g p Pipe Size Threads to Additional <br /> by torquing the threaded <br /> Do not overtighten. (In) (mm) Dry D Fit Threads to Seal <br /> I <br /> connections.However,when I The parts should make up 11/2 40 4-5 3 <br /> the number of threads 2 50 4-5 3 <br /> installing molded threaded shown in the table above. 3 80 5-6 3 <br /> bushings(tapered major nominal i Otherwise,a proper seal 4 100 6-7 2 <br /> pipe size x threaded minor I may not be effected when <br /> nominal pipe size)make the I tightened. <br /> tapered bonded joint first and I Isolating flex connectors at the shear valve <br /> I allow it to cure before making up I <br /> the threaded joint.This order of I When flex connectors are directly buried at the dispenser,regulations frequently require <br /> joint make-up will prevent I that they be cathodically protected and provisions be made to avoid stray current <br /> damage to the bushing—electrolysis and corrosion.In such cases the flex connector must be electrically isolated <br /> L___________J from the shear valve and from other metallic components in the system.Experience has <br /> shown that nylon isolation adapters do not perform well inasmuch as the poor <br /> r————————————I mechanical strength of the material results in creep or thread deformation with <br /> Never use a pipe wrench directly I subsequent leakage. <br /> on the pipe:wrench up only on I Ameron manufactures a 11/2 NPT female x 11/2 NPT male fiberglass-reinforced isolation <br /> adapters. I adapter which may be mounted between the flex connector and the shear valve. Follow <br /> L___________J the same general installation procedures as with other NPT threaded fittings.After <br /> applying the sealing compound,hand tighten the adapter.Final make-up requires 11/2 <br /> to 2 additional turns. <br /> 9 Shearvalve <br /> L�11/2 NPT female <br /> F 27/8—� <br /> I 1'/2 NPT Dualoy isolation <br /> /y male adapter <br /> Fig.9-1.The Ameron fiberglass- <br /> reinforced isolation adapter is mounted 13/a <br /> between the flex connector and the 21/4 <br /> shear valve. <br /> SS flex connector <br /> Lr--11/2 NPT male <br /> both ends <br /> 11/2 NPT (by others) <br /> female <br />