Laserfiche WebLink
10 <br /> Repair procedures Dualoy 3000/LCX is very resistant to impact damage.It can be damaged,however, <br /> by paving stakes,large concrete pieces or other hazards.In the event of damage,the <br /> pipe can be repaired using these procedures. <br /> Usually the damaged area is obvious.If the exact location of the damage cannot be <br /> determined, it may be necessary to replace that full length of pipe.Standard leak <br /> detection methods(soapy water)can be applied progressively along the length of pipe <br /> to locate the damaged or defective section.If the primary pipe is leaking at an unknown <br /> location,the cut ends of the jacket at each end of each piece of pipe can be soaped to <br /> isolate the leak.If the containment pipe is leaking,the surface can be soaped. <br /> Minor damage(isolated to less than one inch of pipe length) <br /> • Cut out the damaged pipe. <br /> • Remove the jacket and taper each of the ends of the remaining pipe <br /> • Place the nuts,O-rings and coupling sleeve(2")on the pipe. <br /> • Assemble coaxial coupling or primary coupling(molded coupling sleeve <br /> placed on pipe)following standard installation practices. <br /> • Close containment system and retest. <br /> Minor damage[containment only](isolated to less than one inch of pipe length) <br /> • Sand area around damaged area- approximately one inch in all directions. <br /> • Recover cut jacket section from field jacket removal tool,remove tape and <br /> sand from inner surface.Sand inner surface. <br /> • Apply thin coating of adhesive to sanded surfaces. <br /> • Wrap jacket section over pipe and secure in place until adhesive cures. <br /> Major damage(greater than one inch of pipe length) <br /> • Remove at least 15 inches of pipe length or the full length of pipe if damaged <br /> area is greater. <br /> • Remove the jacket and taper each of the ends of the remaining pipe <br /> • Dry fit two couplings and intermediate pipe nipple into the gap. <br /> • Place the nuts,O-rings and coupling sleeve(2"and 3")or closure pieces on <br /> the pipe and slide back out of the way. <br /> • Proceed as above for each end of repair area.Finished repair is as shown below. <br /> Once the pipe is buried and the site is paved,repair requirements are extremely rare <br /> for Dualoy 3000/LCX.If the pipe does become damaged,sections can be isolated <br /> and tested between sumps to locate the problem area.Pavement may need to be <br /> removed to access the damaged pipe. <br /> Fig. 10-1.Completed repair section <br /> using 3-and 4-inch Dualoy 3000/LCX <br /> coupling assembly <br /> 11 Primary system Recommended practices <br /> testing Plan tests carefully and carry them out with all due precautions.Pressurizing <br /> r———————————1 equipment should be suited to the size of the system and the pressure required and <br /> These recommendations are offered I should be operated by qualified and experienced personnel only. <br /> only as a guide.Ameron assumes no <br /> responsibility or liability for the Pressure sources should be capable of approaching test pressure gradually. <br /> consequences of any testing I <br /> practices. Use gauges with a full-scale reading of no more than twice the test pressure: <br /> L___________J Do not use a 100 psi gauge for a 10 psi test.Use reliable gauges calibrated <br /> r___________, against a dead weight tester and zeroed for atmospheric pressure. <br /> Ameron recommends hydrostatic I Isolate tanks from the piping when pressure testing. <br /> testing of primary systems as the <br /> effects of sudden pressure loss when 1 The recommended hydrostatic pressure is 150%of expected operating <br /> testing with liquids are far less severe I pressure and should be maintained at least 10 minutes. <br /> than with gases.If pneumatic testing I Do not exceed 150%of system rating.Check the pressure rating of all the <br /> is necessary,restrain the system <br /> adequately to prevent damage or I components of the system—not just the pipe—because hoses and flexible <br /> injury in case of rapid pressure loss. I connectors are almost always rated lower than the pipe. <br /> Pneumatic testing can be extremely . Do not adjust fittings while system is under pressure.If threaded adapters or <br /> dangerous and is not recommended. <br /> L-----------J bushings leak,release the pressure before attempting to tighten. <br /> • Temperature changes can affect the pressure in the test line.Substantial <br /> pressure increases may occur in closed systems exposed to the sun. <br />