Laserfiche WebLink
SWRCB.January 2002 Page 4 of 7 <br /> BEACON FOOD SHOP <br /> 2185 E.Fremont St. <br /> Stockton,CA 95205 <br /> 10.27.04 <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: [ ] Sump Manufacturer [X] Industry Standard [ ] Professional <br /> Engineer <br /> [ ]Other(Spec) <br /> Test Method Used: [ ] Pressure [ ]Vacuum [X]Hydrostatic <br /> [ ]Other(S eco <br /> Test Equipment Used: CALDWELL LEVEL GAUGE Equipment Resolution: 0.0025 <br /> Sump#Regular Sump#Super Sump#Diesel <br /> Sump Diameter: 42 INCH 42 INCH 42 INCH <br /> Sump Depth: 39 INCH 39 INCH 39 INCH <br /> Sump Material: FIBERGLASS FIBERGLASS FIBERGLASS <br /> Height from Tank Top to Top of 11 INCH 11 INCH 11 INCH <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 19 INCH 19-1/4 INCH 19 INCH <br /> Electrical Penetration: <br /> Condition of sump prior to testing: DRY/CLEAN DRY/CLEAN DRY/CLEAN <br /> Portion of Sump Tested 1 26 INCH 26 INCH 26 INCH <br /> Does turbine shut down when sump [X]YES [ ]NO [X]YES [ ]NO [X]YES[ ]NO [ ]YES[ ]NO <br /> sensor detects liquid(both product& [ INA [] NA [ INA [ INA <br /> water)? <br /> Turbine shutdown response time: <br /> Is system programmed for fail-safe [X]YES [ ]NO [X] YES[ ]NO [X]YES[ ]NO [ ]YES[ ]NO <br /> shutdown? [ INA []NA [ INA [ INA <br /> Was fail-safe verified to be [ ]YES[X]NO [ ]YES[X]NO []YES[X]NO [ ]YES[ ]NO <br /> operational? [ INA [ INA [ INA [ INA <br /> Wait time between applying <br /> pressure/vacuum/water and starting 5 MIN. 5 MIN 5 MIN <br /> test: <br /> Test Start Time: 11:00 A.M. 10:15 A.M. 9:45 A.M. <br /> Initial Reading(RI): 26 INCH 26 INCH 26 INCH <br /> Test End Time: 12:00 P.M. 11:15 A.M. 9:50 A.M. <br /> Final Reading 26 INCH 26 INCH 26 INCH <br /> Test Duration: 1 HOUR 1 HOUR 1 HOUR <br /> Change in Reading Rf-RI) -0- -0- -0- <br /> Pass/Fail Threshold or Criteria: No Change in Reading No Change in Reading No Change in Reading <br /> Test Result: [X]PASS [ ] FAIL [X] PASS [ ]FAIL [X] PASS [ ] FAIL [ ]PASS[ ]NO <br /> Was sensor removed for testing? [X]YES [ ]NO [X]YES [ ]NO [X]YES [ ]NO [ ]YES [ ]NO <br /> NA NA NA NA <br /> Was sensor properly replaced and [X]YES [ ]NO [X]YES [ ]NO [X] [ ]YES[ ]NO <br /> verified functional after testing? [ ]N/A [ ]N/A []YES [ ]NO [ INA <br /> N/A <br /> Comments—(include information on repairs made prior to testing,and recommended follow-up for failed tests) <br /> 1 If the entire depth of the sump is not tested,specify how much was tested. If the answer to any of the questions indicated with an asterisk(')is "NO"or <br /> "NA",the entire sump must be tested. (SWRCB LG-160) <br />