SWRCB.January 2002 Page 5 of 7 <br /> BEACON FOOD SHOP <br /> 2185 E.Fremont Street <br /> Stockton,CA 95205 <br /> 10.27.04 <br /> 7. UNDER-DISPENSER CONTAINMENT C TESTING <br /> Test Method Developed By: [ ]UDC Manufacturer [X]Industry Standard [ ]Professional Engineer <br /> [ ]Other(Specie) <br /> Test Method Used: [ ]Pressure [ ]Vacuum [X]Hydrostatic <br /> [ ]Other(Spec) <br /> Test Equipment Used: CALDWELL TEST GAUGE Equipment Resolution: 0.0025 <br /> UDC# 1 UDC# 2 UDC#3 UDC#4 <br /> UDC Manufacturer: Containment Containment Solutions Containment Solutions Containment Solutions <br /> Solutions <br /> UDC Material: Poly Poly Poly Poly <br /> UDC Depth: 24 INCH 24 INCH 24 INCH 24 INCH <br /> Height from UDC Bottom to <br /> Top of Highest Piping 11-1/2 INCH 11-1/2 INCH 11-1/2 INCH 11-1/2 INCH <br /> Penetration: <br /> Height from UDC Bottom to <br /> Lowest Electrical 4 INCH 4 INCH 4 INCH 4 INCH <br /> Penetration: <br /> Condition of UDC prior to DRY DRY DRY DRY <br /> testing: <br /> Portion of UDC Tested 1 14 INCH 14 INCH 14 INCH 14 INCH <br /> Does turbine shut down [X]YES[ ]NO [X]YES[ ]NO [X]YES[ ]NO [X]YES[ ]NO <br /> when UDC sensor detects [ ]NA [ ]NA [ ]NA [ ]NA <br /> liquid(both product& <br /> water)? <br /> Turbine shutdown response <br /> time: <br /> Is system programmed for [X]YES [ ]NO [X] YES[ ]NO [X]YES[ ]NO [X]YES( ]NO <br /> fail-safe shutdown? I NA NA NA NA <br /> Was fail-safe verified to be [ ]YES[X]NO [ ]YES[X]NO [ ]YES[X]NO [ ]YES[X]NO <br /> operational? I NA I NA f INA NA <br /> Wait time between applying <br /> pressure/vacuum/water& <br /> starting test <br /> Test Start Time: 10:45 A.M. 11:15 A.M. 11:50 A.M. 12:05 P.M. <br /> Initial Reading(RI): 14 INCH 14 INCH 14 INCH 13-3/4 INCH <br /> Test End Time: 11:15 A.M. 11:45 A.M. 12:20 P.M. 12:35 P.M. <br /> Final Readin 14 INCH 14 INCH 14 INCH 14 INCH <br /> Test Duration: 30 MIN 30 MIN 30 MIN 30 MIN <br /> Chane in Reading -RI -0- -0- -0- -0- <br /> Pass/Fail Threshold or -0-NO CHANGE -0-NO CHANGE -0-NO CHANGE -0-NO CHANGE <br /> Criteria: <br /> Test Result: 1XI PASS I I FAIL 1XI PASS I I FAIL 1XI PASS I FAIL 1XI PASS I I FAIL <br /> Was sensor removed for [X]YES [ ]NO [X]YES [ ]NO [X]YES [ ]NO [X]YES [ ]NO <br /> testing? N/A f I N/A N/A N/A <br /> Was sensor properly replaced [X]YES [ ]NO [X]YES [ ]NO [X]YES [ ]NO [X]YES [ ]NO <br /> and verified functional after [ ]N/A []N/A [ ]N/A [ ] N/A <br /> test? <br /> Comments—(include information on repairs made prior to testing,and recommended follow-up for failed tests) <br /> 1 If the entire depth of the UDC is not tested,specify how much was tested. If the answer to any of the questions <br /> indicated with an asterisk(*)is "NO"or"NA",the entire sump must be tested. (SWRCB LG-160) <br />