5400
>
2800 - Aboveground Petroleum Storage Program
>
PR0545140
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 3:46:02 PM
Creation date
1/10/2020 9:28:05 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0545140
PE
2832
FACILITY_ID
FA0025200
FACILITY_NAME
CECCHINI TRUCKING CO INC, CTC CFC
STREET_NUMBER
5400
Direction
W
STREET_NAME
STATE ROUTE 12
City
LODI
Zip
95242
APN
05516072
CURRENT_STATUS
01
SITE_LOCATION
5400 W HWY 12
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
94
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Cecchini Trucking Company Inc. <br />SPCC Plan <br />April 2020 <br />Page 32 of 63 <br />• Visual inspection of all product piping for signs of leaks, corrosion, deterioration, or <br />other structural problems; <br />• Proper pump operation; <br />• Electrical connections and grounding; <br />• Visual inspection of all fuel hoses and nozzles to look for signs of wear, weakness, <br />defects, or leaks; <br />• Visual inspection and inventory of the spill kits to make sure they are in the <br />designated locations and are adequately stocked with material that is not weathered <br />or damaged which would make it ineffective; <br />• Test emergency shut off switches to make sure they are functioning properly; <br />• Fuel level monitoring equipment installed on bulk storage tanks is inspected and <br />maintained according to the manufacturer's recommendations; and, <br />• Checking the interstitial space to ensure there is no leakage from the inner wall. The <br />facility management will consider monitoring the interstitial space electronically for the <br />large 12,000 -gallon diesel tank. <br />7.2.2 Integrity Testing <br />40 CFR Part 112.8 (c)(6) requires integrity testing of all bulk oil storage tanks. All the bulk <br />storage containers at Cecchini Trucking are tested periodically according the STI SP001 <br />standard which is the only industry standard that pertains to the type of tanks installed at the <br />facility. Refer to the tables below which identify the Category and Testing intervals for each <br />tank installed at the facility based upon the STI SP001 industry standard. <br />The 12,000 -gallon diesel tank is shop -fabricated and is a Category 1 tank. The STI <br />SP001 standard requires this tank to be periodically inspected according to the STI <br />SP001 Inspection Checklist (Monthly & Annual). A formal periodic external (P, E) <br />inspection is required every twenty (20) years by a Certified Inspector. Based on the <br />paperwork that came with the tank, the last STI inspection was performed on March <br />24, 2006 when the tank shipped from the manufacturer, Modern Welding Company of <br />California Inc. The next STI inspection is due in 2026. <br />Note: See Section 5.0 (Inspection Schedule) and Section 6.0 (Periodic AST <br />Inspections) in the Standard for the Inspection of Aboveground Storage Tanks <br />Guidebook (Issued September 2011, 5th Edition). Please note that a copy of the <br />Guide is not included in this SPCC Plan, however Tables 7 and 8 (in this Plan) are <br />taken from the Guide. <br />
The URL can be used to link to this page
Your browser does not support the video tag.