My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
R A BRIDGEFORD
>
7850
>
2231-2238 – Tiered Permitting Program
>
PR0521782
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/10/2020 9:52:56 AM
Creation date
1/10/2020 9:38:25 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2231-2238 – Tiered Permitting Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0521782
PE
2236
FACILITY_ID
FA0014789
FACILITY_NAME
SJC PERMANENT HOUSEHOLD HAZ WASTE
STREET_NUMBER
7850
Direction
S
STREET_NAME
R A BRIDGEFORD
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
17726034
CURRENT_STATUS
01
SITE_LOCATION
7850 S R A BRIDGEFORD ST
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S b N J 0 A Q U I N Environmental Health Department <br /> COUNTY <br /> Permanent Household Hazardous Waste Collection Facility Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SJC PERMANENT HOUSEHOLD HAZ WASTE 7850 S RA BRIDGEFORD ST, STOCKTON July 10, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 207 CCR 67450.25(a)(2)(G) Failed to comply with all applicable requirements fo the tank system. <br /> 1) OBSERVATION: The facility is not performing and documenting complete daily inspections of the secondary <br /> containment for the used antifreeze hazardous waste tank. The secondary containment vent is not being opened to <br /> inspect the tank annular space for leaks from the primary containment. <br /> Per Title 22 California Code of Regulations(CCR)67450.25(G), Permanent Household Hazardous Waste Collections <br /> Facilities(PHHWCFs)are required to maintain compliance with Title 22 CCR 66265.195. The following items are <br /> required to be inspected at least daily: <br /> 1. overfill/spill control equipment; <br /> 2. aboveground portions of the tank system to detect corrosion or releases of water; <br /> 3. data gathered from monitoring and leak-detection equipment; <br /> 4. outside areas of the tank system including secondary containment to detect erosion or signs of releases of <br /> hazardous waste; <br /> 5.for uncovered tanks, the level of waste in the tank. <br /> CORRECTIVE ACTION: Immediately begin required inspections of the hazardous waste tank system, and <br /> document the items inspected. Submit a copy of the inspection log for the next 30 days to the EHD. <br /> 2) OBSERVATION:The facility did not have a tank assessment available for review during the inspection for the two <br /> 500 gallon used oil tanks. <br /> Per Title 22 CCR 67450.25(G), PHHWCFs are required to maintain compliance with Title 22 CCR 66265.192. The <br /> owner or operator of a hazardous waste tank shall obtain a written assessment reviewed and certified by an <br /> independent, qualified, professional engineer, registered in California attesting that the system has sufficient <br /> structural integrity, is acceptable for the transferring, storing, and treating of hazardous waste, and that the tanks <br /> and containment system are suitably designed. <br /> CORRECTIVE ACTION: Immediately submit a copy of the hazardous waste tank assessments for the two 500 <br /> gallon used oil hazardous waste tanks. If a tank assessment has not been completed, immediately have <br /> assessments prepared for the two 500 gallon used oil tanks. <br /> 3) OBSERVATION: The 500 gallon used oil tank(on the left if facing the main building)was missing an <br /> accumulation start date. <br /> Per Title 22 CCR 67450.25(a)(1), PHHWCFs are required to maintain compliance with Title 22 CCR 66262.34(f).All <br /> hazardous waste tanks shall be marked with the words"Hazardous Waste"and the accumulation start date. <br /> Immediately ensure that all hazardous waste tanks are marked with the required information. <br /> The labeling violation (3)was corrected on site during the inspection. <br /> This is a repeat violation, Class ll. <br /> FA0014789 PR0521782 SCO01 07/10/2019 <br /> EHD 22-07 Rev.05/15/2019 Page 4 of 6 Permanent Household Hazardous Waste Collection Facility <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.