Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department DIRECTOR <br /> o Donna Horan,REHS <br /> y vf , y� 600 East Main Street PROGRAM COORDINATORS <br /> N. ; < Stockton, California 95202-3029 <br /> Robert McClellan,REHS <br /> .• +• Jeff Carruesco,REHS,RDI <br /> Kasey Foley.REHS <br /> Website: www.S/gov.org/ehd Linda Turkatte,REHS <br /> V C%FOR <br /> Phone: (209)468-3420 <br /> Fax: (209)464-0138 <br /> March 1, 2012 <br /> V <br /> Mr. Michael Karvelot Mr. Wayne Adachi <br /> Quik Stop Markets, Incorporated Adachi Investment, LLC Etal <br /> �. 4567 Enterprise Street 1991 Sun Mor Avenue <br /> Fremont, California 94538 Mountain View, California 94040 <br /> Subject: Quik Stop Markets No. 132 LOP Case No.: 1130 <br /> 3555 West Hammer Lane <br /> Stockton, California 95209 <br /> v <br /> The San Joaquin County Environmental Health Department (EMD) has received a No Further <br /> Action Required Concurrence letter from the Central Valley Regional Water Quality Control <br /> Board (CVRWQCB) dated 14 February 2012 for the above referenced site. It is now necessary <br /> to plan and execute the destruction of all wells installed as part of your site investigation and <br /> remedial action, as the EHD will not issue a Case Closure Letter for this site until the wells have <br /> been properly destroyed and all onsite waste material has been removed and properly <br /> disposed. The wells are to be destroyed within 90 days of the date of this letter, or current <br /> analytical data for groundwater collected quarterly from the wells shall be submitted for review <br /> until the wells have been properly destroyed. <br /> Please submit a scope of work proposal that details the conditions and construction of the wells <br /> and the methods and materials to be used to destroy them. To be issued a well destruction <br /> ,.., permit, the proposal must address the concerns of the EHD and the San Joaquin County Well <br /> Standards requirements, such as: <br /> • Wells that have laboratory data from the last sampling event that demonstrate the <br /> presence of any contaminants of concern are to be destroyed by removing all the <br /> contents of the well (conductor casing, well casing, screen, filter pack, grout sealant); <br /> the cleared borehole is then to be sealed with neat cement by pressure grouting from <br /> the bottom upward to a depth of three to five feet below grade. <br /> All wells with unknown construction and/or located in an area of known or suspected <br /> area of contamination are to be destroyed by removing all the contents of the well <br /> (conductor casing, well casing, screen, filter pack, grout sealant); the cleared borehole <br /> is then to be sealed with neat cement by pressure grouting from the bottom upward to a <br /> depth of three to five feet below grade. <br />