15600
>
2800 - Aboveground Petroleum Storage Program
>
PR0515456
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/4/2020 2:53:28 PM
Creation date
2/21/2020 1:36:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0515456
PE
2832
FACILITY_ID
FA0000174
FACILITY_NAME
JOES TRAVEL PLAZA
STREET_NUMBER
15600
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19620079
CURRENT_STATUS
01
SITE_LOCATION
15600 S HARLAN RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
172
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> Table F —Tank Inspection Summary <br /> II <br /> Periodic Formal Formal <br /> STI Storage External External Leak Test j <br /> Tank ID Inspection <br /> Category Capacity Interval Inspection Inspection Interval <br /> Interval Interval <br /> (gallons) Monthly Yearly (years) (years) (years) <br /> AST-1 11 10;000 Yes Yes 20` _ NR NR <br /> AST-2 1 10,000 Yes Yes 20 NR NR <br /> A8T-3 1 10;000 -Yes Yes 20 AR' NR <br /> AST-4 1 10,000 Yes Yes 20 NR NR <br /> Drums 1 55 each Yes Yes NR* NR* NR* <br /> NR=Not Required <br /> *=Owner shall either discontinue use of portable container for storage or have the portable container DOT <br /> (Department of Transportation)tested and recertified per the following schedule <br /> Plastic portable container-every 7 years <br /> Steel portable container-every 12 years <br /> Stainless Steel portable container-every 17 years <br /> Periodic AST Inspections (Monthly and Yearly) / <br /> Visual inspections of ASTs by facility personnel are performed according to the procedure described in <br /> this SPCC Plan. The visual inspections should consist of a complete walk-through of the facility <br /> property to check the tanks,tank connections, and above ground product piping, and for damage or <br /> leakage, check for stained or discolored soils, and to ensure complete site security. Any problems or <br /> leaks identified by the visual inspection shod be promptly addressed and remedied. <br /> i <br /> The facility should have a visual inspection perfoi7ne minimum of once per month using the STI <br /> SP-001 Monthly Inspection Checklist and the STI SP O1 Portable Container Monthly Inspection <br /> Checklist included as Attachment B. Annual ins p ions for the ASTs should be conducted using the <br /> STI SP-001 Annual Inspection checklist includ in Attachment B. Records of inspections should be <br /> kept with this plan for at 1 t five year . <br /> External AST Inspections <br /> i <br /> Based on the size and STI SP-001 011 category of the ASTs at the site, formal external inspections are <br /> required to be performed by a certified inspector at a minimum of every 20 years from the date of <br /> installation. The formal external inspection should be conducted in accordance with the STI standard <br /> and should include a detailed inspection and/or testing of the ASTs,piping, containment, vents, fill <br /> ports, supports, foundations, overfill prevention devices, and other tank appurtenances. The exact scope <br /> of inspection varies depending on the facility and the exact scope of external inspection necessary to <br /> comply with the STI SP-001 2011 standard at the site must be determined by the certified inspector. <br /> Tanks AST-1 through AST-4 were reportedly installed in 1999; therefore,the next formal external tank <br /> evaluation should be conducted in 2019. <br /> I, <br /> Records of certified tank inspections should be kept for the life of the tank. Internal inspections, leak <br /> testing, and shell test comparisons are not required for any tanks or containers at the site but records of j <br /> these tests should be retained for the life of the tank if performed. <br /> Joe's Travel Plaza <br /> 15600 Harlan Road,Lathrop,CA <br /> Page 19 <br />
The URL can be used to link to this page
Your browser does not support the video tag.