Laserfiche WebLink
California (Figure 2 The station has four <br /> Mariposa Road and Farmington Road in Stockton, {F g ) <br /> underground storage tanks (UST's), of which three are 12,000 gallon gasoline tanks and one is <br /> a 3,000 gallon diesel fuel tank (Figure 3) All four tanks appear to be located in the same tank <br /> pit excavation near the Manposa Road side of the property <br /> 2.2 Site History <br /> Three phases of site assessment have been performed at this facility The first, as part of a pre- <br /> purchase due diligence by Pacific Environmental Group, consisted of the drilling and sampling <br /> of four soil borings, one of which was completed as a groundwater monitoring well <br /> ' Groundwater was present at about 45 feet bgs Soil sample analyses from these borings <br /> indicated that there were TPH and BTEX constituents present in shallow soils and soils lust <br /> above the water table One groundwater sample contained BTEX compounds above state action <br /> ' levels <br /> The presence of petroleum hydrocarbon compounds in the soil and groundwater beneath the site <br /> ' prompted a second site assessment conducted by Applied GeoSystems This second phase of <br /> work consisted of the drilling and installation of two additional groundwater monitoring wells <br /> Groundwater sample analyses from these wells confirmed that TPH compounds were present in <br /> ' the groundwater beneath the site The direction of groundwater movement was calculated to be <br /> in a north-westerly direction <br /> As a result of these findings PHS/EHD requested that a quarterly groundwater monitoring <br /> program be initiated for this location, plus a request that all domestic groundwater wells be <br /> identified and sampled Six domestic wells were located and sampled Test results presented <br /> in a May 13, 1987 letter report prepared by Applied GeoSystems were non detect for TPH and <br /> BTEX The next quarterly sampling could not be performed because the groundwater table had <br /> declined below the bottom of the monitoring wells <br /> In the third work phase, Park replaced the three groundwater monitoring wells at the site in <br /> September, 1992 One shallow vapor extraction well was also installed during the additional site <br /> ' characterization Also performed were quarterly groundwater sampling and a vapor extraction <br /> treatability study Results from this latest work confirmed the presence of petroleum <br /> hydrocarbons in the soil and groundwater In late September, groundwater was calculated to <br /> be flowing south southeast, while in October, January and February, 1993 was flowing <br /> northeasterly Groundwater was approximately 75 feet bgs <br /> ' 2.3 Area Background <br /> ' Prior consultants have indicated that all four corners at the intersection have had operating retail <br /> gasoline service stations on them at one time or another No site assessments have been <br /> performed at any of these other corners <br /> ' An abandoned Chevron service station is present on the northeast corner This ,property is <br /> IPA 1125J2 WP 3 <br />