lFelox,fair/NC. <br /> 1.2 Site Location and Layout <br /> The Site is located at 234 West Main Street, Ripon, San Joaquin County, California. It is <br /> located approximately '/4 mile southwest of State Highway 99. The Site is currently utilized as <br /> B of A's Ripon Branch No. 0852. It consists of a two-story commercial office building with <br /> paved, street-level parking, and landscaped areas on 14,418 square feet of land. <br /> 1.3 Background <br /> In April 1997, Versar was retained by B of A to perform a Phase I ESA at the Site. The <br /> adjoining and surrounding properties were also investigated to identify any off-site <br /> environmental issues that have the potential to impact the Site. The Phase I ESA identified the <br /> presence of former auto repair facilities on the Site. <br /> In May 1997, Versar, on behalf of B of A, conducted a Phase 11 subsurface investigation <br /> to further assess conditions from former facilities located at the Site reported in the Phase I ESA. <br /> The Phase II investigation found low concentrations of total petroleum hydrocarbons as diesel <br /> (TPH-D) in groundwater near the west boundary of the Site. <br /> B of A and Bank of Stockton requested additional assessment of Site soil and shallow <br /> groundwater conditions with respect to the potential presence of solvents, which may have been <br /> used during previous auto repair operations conducted at the Site in the 1940s as identified <br /> during Versar's Phase II investigation. <br /> 2.0 SITE INVESTIGATION FIELD PROCEDURES AND RESULTS <br /> This section describes the additional information obtained regarding groundwater flow <br /> direction in the Site area, permitting, Site health and safety procedures, drilling procedures, soil <br /> sampling and analytical results, and groundwater sampling and analytical results. <br /> 2.1 Groundwater Flow Direction in the Site Area <br /> Versar contacted the San Joaquin County Environmental Health Department (SJCEHD) <br /> for information on groundwater flow direction at SJCEHD case sites near the project Site. Mr. <br /> Mike Infurnia of SJCEHD reported to Versar that groundwater flowed to the north/northwest <br /> near Highway 99, several blocks northeast of the Site, and southwest at 334 Main Street, one <br /> block from the Site. Based on this information, Versar considered the groundwater flow <br /> direction at the Site to be variable. <br /> -98/3622-501/Sep04'97 2 <br />