My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2003 - 2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
713
>
2300 - Underground Storage Tank Program
>
PR0521604
>
COMPLIANCE INFO_2003 - 2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/13/2023 11:14:59 AM
Creation date
3/25/2020 4:23:30 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003 - 2008
RECORD_ID
PR0521604
PE
2371
FACILITY_ID
FA0014678
FACILITY_NAME
NATIONAL PETROLEUM
STREET_NUMBER
713
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95202
APN
13905214
CURRENT_STATUS
01
SITE_LOCATION
713 N EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
272
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PIPING SUMP CONTAINMENT TESTING <br /> Test Method By: Manufacturer • Industry Standard Professional Engr. Other(see below) <br /> Test Method Uses: Pressure vacuum • Hydrostatic Other(see below) <br /> Measuring Equipment Used: INCON TS-STS (Electronic Sump Test System) <br /> Descriptio-- Tank#1 Tank#2 Tank#3 dk <br /> Sump material FRP FRP FRP <br /> Sump diameter (inches) 42" 42" 42" <br /> Sump depth (inches) 65" 76" 72" <br /> Tank product Gasoline-87 Gasoline-91 Diesel <br /> Height from tank top to highest 19" 18" 14" <br /> piping penetration <br /> Height from tank top to lowest 22" 24" 16" <br /> electrical penetration <br /> Method of sump attachment to tank Tank Collar Tank Collar Tank Collar <br /> Type of sump penetration fittings Environ Environ Environ <br /> Condition of sump prior to testing Dry Dry Dry <br /> Portion of sump tested Entire EntireEntire <br /> Is system programmed for fail-safe operation Yes Yes Yes <br /> Was fail-safe verified to be operational? No No No <br /> Was sensor removed for testing? Yes Yes Yes <br /> Was sensor properly replaced after testing? Yes Yes Yes <br /> Wait time for water level to stabilize (hr:min) 0:10 0:10 0:10 <br /> Depth of water level from tank top (inches) 24" 26" 18" <br /> Test start time 10:42 AM 10:42 AM 10:42 AM <br /> Test end time 10:57 AM 10:57 AM 10:57 AM <br /> Test duration (hr:min) 0:15 0:15 0:15 <br /> Change in water level (t 0.000 inches) 0.000 0.002 0.000 <br /> Pass/Fail threshold (0.005 inches/'/:Hr.) 0.005 0.005 0.005 <br /> TEST RESULT PASS PASS PASS <br /> Comments: <br /> 2003 Walton Engineering,Inc. <br />