evine•Fricke•Recon <br /> ENGINEERS,HVDROGEOLOGISTS 8 APPLIED SCIENTISTS <br /> • A-zone monitoring wells were installed from April 15 through May 9, 1997, at the following <br /> locations: near Gettysburg Place on Calhoun Way (MW-103A) and Stanton Way (MW-105A), <br /> on Lincoln Elementary School (on the corner of Pacific Avenue and Lincoln Road [MW- <br /> 106A]), and on Emeryn Street near Lincoln Road (MW-107A; Figure 1). <br /> • Pilot soil boring PB-300, B-zone monitoring well MW-201B, and C-zone monitoring well <br /> MW-300C were installed at the plume perimeter location on Emeryn Street near Lincoln Road <br /> from April 8 through May 10, 1997 (Figure 1). <br /> • Pilot soil boring PB-202131 and PB-202132 were installed at the plume perimeter location <br /> behind Village Cleaners at Lincoln Center from May 12 through 16, 1997 (Figure 1). <br /> • The shallow soil-vapor investigation in and around the suspected source areas along selected <br /> sanitary sewer lines at Lincoln Center continued through April and May and is ongoing. <br /> • CPT and PIPP sampling were conducted at source area locations at Lincoln Center from April <br /> 28 through May 19, 1997. <br /> • As part of the monitoring well MW-21 evaluation, groundwater quality in the vicinity of <br /> MW-21 was investigated by drilling a pilot boring and collecting PIPP samples from individual <br /> sand layers in the B-zone aquifer. Based on the results of groundwater sample analyses, <br /> monitoring wells MW-203B(1), MW-203B(2), and MW-203B(3) were installed and screened <br /> across three depth intervals in the B-zone aquifer. This work was conducted from May 19 <br /> through 29, 1997 (Figure 1). <br /> • Survey activities were conducted on April 14 through 18, 1997, to obtain top-of-casing <br /> elevations for newly repaired monitoring wells MW-1 through MW-4 and MW-8, and newly <br /> installed monitoring well MW-102; and to obtain horizontal locations and ground surface <br /> elevations for the soil-vapor sample locations and the CPT/PIPP borings installed during the <br /> source area investigation and the Interim Remedial Action (IRA) activities. <br /> • Access negotiations continued with private property owners and their tenants to obtain <br /> permission to conduct Remedial Investigation and IRA activities on adjacent properties. <br /> Although access agreements have been finalized between the SDCDs and the neighboring <br /> property owners and tenants at Lincoln Center, permission to proceed with the field work has <br /> not yet been received from all of those parties. <br /> 411 t-E97.BMM:SRL 2 <br />