EQUIPMENT SCHEDULE 208 HCD <br />MARK <br />MAKE <br />MODEL <br />BESC, <br />CAPACITIES <br />AMB <br />102 <br />ELECTRICAL <br />ITEM QTY VOLT <br />PH <br />ACCESSORIES <br />CFM <br />HEAT <br />COOLING <br />RTU -1 <br />950 <br />MAU-1 <br />2880 <br />IN/OUT <br />T❑T/SENS <br />12"x6" SUPPLY DIFFUSER WITH 6" ROUNDNECK OBD, <br />LINED DUCT WITH INSULATION <br />ADJUSTABLE 1 -WAY THROW EQUAL TO TITUS MODEL 350RL <br />RTU -1 <br />CARRIER <br />PACKAGE <br />3000 <br />125 <br />89.0 <br />85 <br />FLA 33.7 2087 <br />W/ ECONOMIZER <br />7.5 TON <br />48HCD08 <br />GAS <br />0.5" <br />103 <br />72.9 <br />65 <br />3PH <br />HIGH STATIC MOTOR <br />4. PROVIDE BALANCING DAMPERS AT BRANCH TAP. <br />383D <br />ELECTRIC <br />TOTAL EXHAUST AIR: -3675 <br />AFUE <br />12 EER <br />MD DM <br />MCA 49.3, MOCP <br />ROOF CURB WT=1 100# <br />EF -1 EF -2 EF -3 <br />IF <br />MAU-1 <br />RTU -1 <br />82% <br />13.8 IEER <br />M.U.A. E.A. E.A. E.A. <br />60 <br />KITCHEN AREA <br />NOTES: <br />1. NEW ROOFTOP UNITS SHALL BE CARRIER 48HC HIGH EFFICIENCY MODELS IN GAS HEATING AND ELECTRIC <br />COOLING WITH THE FOLLOWING ACCESSORIES: <br />A. 14" HIGH STANDARD FLAT ROOF CURBS SHALL BE FACTORY SUPPLIED AND FIELD INSTALLED BY <br />MECHANICAL CONTRACTOR UNLESS SPECIFIED OTHERWISE BY THE MECHANICAL ENGINEER. <br />B. INTEGRATED ECONOMIZER WITH RELIEF FAN SHALL BE FACTORY PROVIDED AND FIELD INSTALLED BY <br />MECHANICAL CONTRACTOR. <br />C. SUPPLY AND RETURN AIR SMOKE DETECTORS SHALL BE FACTORY PROVIDED, INSTALLED AND WIRED. <br />D. VERIFY INDOOR BLOWER (EVAPORATOR FAN) MOTOR AND DRIVE REQUIREMENTS FOR EACH UNIT PER <br />CFM/STATIC PRESSURE REQUIREMENTS SHOWN ON SCHEDULE. <br />E. PROVIDE AN ECONOMIZER FAULT DETECTION AND DIAGNOSTICS AS REQUIRED BY CEC. <br />SYSTEM AIR BALANCE SCHEDULE <br />DESIGNATION <br />EXHAUST <br />CFM <br />OUTSIDE AIR <br />CFM <br />MAKE-UP AIR <br />CFM <br />EF -1 <br />1000 <br />RTU -1 <br />950 <br />MAU-1 <br />2880 <br />EF -2 <br />2600 <br />12"x6" SUPPLY DIFFUSER WITH 6" ROUNDNECK OBD, <br />LINED DUCT WITH INSULATION <br />ADJUSTABLE 1 -WAY THROW EQUAL TO TITUS MODEL 350RL <br />6"N <br />EF -3 <br />75 <br />ABOVE FINISHED FLOOR <br />AFF <br />g"N <br />151 - 200 CFM <br />TOTAL EXHAUST AIR: <br />3675 <br />TOTAL OUTSIDE AIR: <br />950 <br />TOTAL MAKE-UP AIR: <br />2880 <br />SYSTEM BALANCE: <br />2. ALL GRILLES IN RESTROOMS TO BE ALUMINUM. ALL OTHERS STEEL UNLESS <br />TOTAL OUTSIDE AIR: 950 <br />3. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION AND <br />TOTAL MAKE-UP AIR: 2880 <br />4. PROVIDE BALANCING DAMPERS AT BRANCH TAP. <br />383D <br />CSFD - CEIL. FIRE SMOKE DAMPER <br />TOTAL EXHAUST AIR: -3675 <br />5 AD -1 DRIVE THRU WINDOW READY ACCESS AA300-275 NA NA 9153 <br />PRESSURIZATION: +155 <br />MD DM <br />2880 M.U.A. <br />950 O.A. <br />EF -1 EF -2 EF -3 <br />IF <br />MAU-1 <br />RTU -1 <br />2880 1000 2600 75 <br />3000 2050 <br />M.U.A. E.A. E.A. E.A. <br />S.A. R.A. <br />KITCHEN AREA <br />LOCATION: FLOOR <br />WALL <br />AIR BALANCE DIAGRAM <br />RTU -1 ROOFTOP UNIT TO BE INTERLOCKED WITH <br />EF -1 & EF -2. <br />THIS WILL ENSURE POSITIVE BUILDING PRESSURE <br />AND BALANCE. <br />WHEN EF -1 & 2 ARE ENERGIZED RTU --1 FAN SHALL COME ON. <br />SPACE TEMPERATURE WILL BE MAINTAINED FROM <br />THERMOSTAT SET POINT. <br />DUCT SENSORS SHALL CYCLE HEAT TO ACHIEVE <br />65 DEGREE OUTSIDE AIR. <br />AIR DEVICE SCHEDULE <br />DESIGNATION <br />DESCRIPTION <br />Sc <br />24x24" SUPPLY DIFFUSER WITH ROUNDNECK 24"x24" <br />ITEM <br />4 -WAY THROW EQUAL TO TITUS MODEL PAS. <br />12" DIA. <br />401- 600 <br />= <br />1/2 <br />SA <br />12"02" SUPPLY DIFFUSER WITH 8" ROUNDNECK OBD, <br />NET INSIDE DIMENSIONS <br />ADJUSTABLE 1 -WAY THROW EQUAL TO TITUS MODEL 350RL <br />- <br />12"x6" SUPPLY DIFFUSER WITH 6" ROUNDNECK OBD, <br />LINED DUCT WITH INSULATION <br />ADJUSTABLE 1 -WAY THROW EQUAL TO TITUS MODEL 350RL <br />6"N <br />50 - 150 CFM <br />SEE DRAWING FOR THICKNESS <br />ABOVE FINISHED FLOOR <br />AFF <br />g"N <br />151 - 200 CFM <br />- - - - - <br />RE <br />24"x24" RETURN GRILLE EQUAL TO TITUS <br />1 115 DIRECT CABINET 10 <br />MODEL 350R <br />NOTES: <br />1. OBD -OPPOSED BLADE DAMPER (REQUIRED AT GYP. CEILINGS). <br />2. ALL GRILLES IN RESTROOMS TO BE ALUMINUM. ALL OTHERS STEEL UNLESS <br />NOTED OTHERWISE. <br />3. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION AND <br />ELEVATION OF DEVICES. <br />4. PROVIDE BALANCING DAMPERS AT BRANCH TAP. <br />FLEX DUCT TO MAIN RUN TO BE <br />MIN 3'2' LENGTH S❑ THAT THE <br />DUCT SIZE AND INSULATION <br />VALUE IS SHOWN ON ALL DUCTS <br />AND MAX LENGTH TO BE 10'0' FOR <br />OSHPD AND 5'0' FOR ALL OTHERS. <br />12' GI DUCT EXTENSION <br />ABOVE CEILING <br />INSULATION, FLEX <br />DUCT TO MAIN RUN <br />24 GAUGE GI REGISTER <br />CAN <br />SCREW CAN TO <br />BLOCKING - 4 TOTAL <br />L -REGISTER - SEE PLAN <br />FOR SIZES - PR❑VIDE <br />1/2' SOUND LINER IN <br />CEILING REG DETAIL REGISTER CAN <br />DETAIL <br />EXHAUST FAN INFORMATION <br />FAN <br />SYMBOL LEGEND <br />JOB NO.: <br />SYMBOL <br />BYPASS, NITESTAT, CLOCK <br />ITEM <br />ABBREV. <br />UNIT TAG SERVES MANUFACTURER FAN UNIT CFM ESP. RPM H.P. <br />N0. MODEL # <br />VOLT DRIVE TYPE WEIGHT (BS.) <br />RECTANGULAR DUCT SIZE <br />1/2 <br />1 115 DIRECT ROOF 71 <br />- <br />NET INSIDE DIMENSIONS <br />WO/ <br />- <br />10.7 <br />LINED DUCT WITH INSULATION <br />2 EF -2 GRILL HOOD CAPTIVEAIRE DU85HFA 2600 0.85 1192 <br />3/4 <br />1 115 DIRECT ROOF 71 <br />SEE DRAWING FOR THICKNESS <br />ABOVE FINISHED FLOOR <br />AFF <br />FLEXIBLE SUPPLY DUCT, CLASS 1 <br />18.4 <br />- - - - - <br />FLEXIBLE RETURN DUCT, CLASS 1 <br />1/4 <br />1 115 DIRECT CABINET 10 <br />VD -VOLUME DAMPER, REQUIRED <br />NONE <br />5D <br />FD - FIRE DAMPER <br />FDR <br />VD <br />FSD FIRE SMOKE DAMPER <br />FSD <br />TBR <br />CSFD - CEIL. FIRE SMOKE DAMPER <br />CSFD <br />5 AD -1 DRIVE THRU WINDOW READY ACCESS AA300-275 NA NA 9153 <br />MD DM - MOTORIZED DAMPER <br />MD DM <br />NA 5H,7 <br />DUCTWORK - GI SPIRAL PIPE <br />CUT OFF POINT <br />IF <br />TURNING VANES <br />TV <br />300 <br />- <br />FIRST LETTER CEILING <br />CS -4 <br />12x12 <br />- <br />LOCATION: FLOOR <br />WALL <br />UON <br />CS -4 <br />SECOND LETTE <br />SUPPLY <br />SERVICE: <br />C. OF <br />HWS - <br />4. ALL FAN MOTORS TO BE TEFC. <br />RETURN <br />Fz] <br />I <br />NUMBER -TYPE: EXHAUST <br />- <br />MACHINE BOLT <br />SEE SCHED. <br />6. PROVIDE MINIMUM 14" HIGH FACTORY INSULATED CURB ON ALL ROOF EXHAUST FANS EXCEPT GREASE <br />7. PROVIDE FAN SPEED CONTROLLER ON ALL DIRECT -DRIVE FANS. <br />EXHAUST FAN INFORMATION <br />FAN <br />THERMOSTAT, UNIT NO. <br />JOB NO.: <br />© ❑N © <br />BYPASS, NITESTAT, CLOCK <br />SONES <br />NOTES <br />UNIT TAG SERVES MANUFACTURER FAN UNIT CFM ESP. RPM H.P. <br />N0. MODEL # <br />VOLT DRIVE TYPE WEIGHT (BS.) <br />1 EF -1 FRYER HOOD CAPTIVEAIRE DU50HFA x,`1000. 0.75 1229 <br />1/2 <br />1 115 DIRECT ROOF 71 <br />- <br />WITH OUT <br />WO/ <br />- <br />10.7 <br />1,4,5A <br />2 EF -2 GRILL HOOD CAPTIVEAIRE DU85HFA 2600 0.85 1192 <br />3/4 <br />1 115 DIRECT ROOF 71 <br />- <br />ABOVE FINISHED FLOOR <br />AFF <br />1 <br />18.4 <br />1,4,5A <br />3 EF -3 RESTROOM GREENHECK SP -B110 75""'0.25 1234 <br />1/4 <br />1 115 DIRECT CABINET 10 <br />- <br />2.0 <br />5D <br />4 MUA-1 FRYER/GRILL HOOD CAPTIVEAIRE A2 -G12 2880 0,65 1212 <br />1 <br />1 115 DIRECT ROOF 331 <br />-X-X->(- <br />DEMOLITION TO BE REMOVED <br />TBR <br />18.7 <br />2,3 <br />5 AD -1 DRIVE THRU WINDOW READY ACCESS AA300-275 NA NA 9153 <br />NA <br />1 208 DIRECT WINDOW 85 <br />NA 5H,7 <br />GENERAL NOTES: APPLICABLE TO ALL FANS <br />CUT OFF POINT <br />COP <br />- <br />1. REFERENCE ELECTRICAL DRAWINGS FOR ELECTRICAL DATA. <br />FBO <br />- <br />UP THROUGH ROOF <br />2. REFERENCE FLOOR PLANS FOR EXACT LOCATION <br />- <br />UNLESS OTHERWISE NOTED <br />UON <br />3. REFERENCE ARCHITECTURAL DRAWINGS FOR ROOF CURB DETAIL. <br />CONDENSATE, OVERFLOW <br />C. OF <br />HWS - <br />4. ALL FAN MOTORS TO BE TEFC. <br />HWS,HWR <br />- CHWS <br />I <br />5. PROVIDE DISCONNECT SWITCH, ON ALL ABOVE CEILING CABINET FANS. <br />- <br />MACHINE BOLT <br />MB <br />6. PROVIDE MINIMUM 14" HIGH FACTORY INSULATED CURB ON ALL ROOF EXHAUST FANS EXCEPT GREASE <br />7. PROVIDE FAN SPEED CONTROLLER ON ALL DIRECT -DRIVE FANS. <br />FAN. <br />G, LPG <br />SPECIFIC NOTES: <br />ALL THREAD ROD <br />ATR <br />- - <br />1. PROVIDE 24" HIGH GREASE CURB AS REQUIRED BY CODE. VENTED EXTENSION, GREASE <br />2. INTERLOCK KITCHEN SUPPLY FANS WITH KITCHEN EXHAUST FANS. <br />TROUGH, <br />HINGED BASE ON GREASE EXHAUST FAN. <br />FEET PER MINUTE <br />3. PROVIDE MAU-1 WITH INTEGRAL BACKDRAFT DAMPER AND BIRD SCREEN. <br />D_ <br />DUCT TEMPERATURE SENSOR <br />DTS <br />4. PROVIDE FANS WITH MOTORS OUT OF AIR STREAM WITH DRIP --PROOF COVERS AND HOUSINGS WITH CORROSIVE RESISTANT COATING ON ALL K <br />PLANS, <br />T'CHEN HOOD <br />5. PROVIDE SWITCHING AS INDICATED BELOW AND IN ACCORDNACE WITH SEQUENCE OF OPERATION. <br />TRADES TO PROVIDE SWITCHING. <br />CONTRACTOR SHALL COORDINATE THE WORK <br />OF ALL <br />5A SWITCH FAN FROM KITCHEN HOOD SWITCH. <br />- <br />STEAM PIPE <br />S <br />56 INTERLOCK SUPPLY FAN WITH RESPECTIVE KITCHEN HOOD EXHAUST FAN <br />STEAM CONDENSATE <br />Sc <br />- <br />5C SWITCH EXHAUST FANS WITH LIGHTS, PROVIDE 15 MIN TIME DELAY RELAY. <br />CW <br />>Q <br />SHUT OFF/BALL VALVE <br />5D SWITCH EXHAUST FANS WITH LIGHTS, PROVIDE 30 MIN TIME DELAY RELAY. <br />- <br />DUCT SMOKE DETECTOR <br />DSD <br />5E PROVIDE LOCAL TEMERPATURE SENSOR ON-OFF CONTROL. <br />5F SHALL OPERATE 24/7, WIRE ALL FANS TO SINGLE LABLED SWITCH AT STAFF STATION PER SMOKE COMPARTMENT. <br />COORDINATE WITH ELECTRICAL CONTRACTOR <br />5G INTERLOCK TO TIMECLOCK, ENERGIZE DURING HOURS OF OPERATION. <br />5H INTERLOCK WITH DRIVE THRU DOOR. <br />6. CABINET FANS SHALL HAVE CEILING RADIATION DAMPERS AT EXHAUST. EHXUAST DUCT <br />FLASH PER ROOFING CONTRACTOR SPECIFICATIONS. <br />SHALL GO <br />UP THROUGH ROOF TO TURN DOWN, SIZ <br />PER PLANS, <br />7. 7.1 KW HEAT, 32 A, 600 FPM DISCHARGE AIR VELOCITY. <br />^1 i <br />12x12 - GRILLE NECK SIZE IN INCHES HVAC Notes1. Furnish and install alt ductwork in accordance with the latest editions of CMC (SMACNA duct construction standards), <br />PROVIDE VD'S LL ALL D RE AND TAPS 2. All Pipes, ductwork and conduit shall be installed and seismical) braced per SMACNA's <br />SUPPLYING GRILLES AND REGISTERS FOR p p y p Seismic Restraint Guidelines, ❑SHPD pre- pproval #80010, <br />CE -1 AIR BALANCING PER T--24, 3. All contractor furnished equipment installation and startup instructions shall be kept with the piece of equipment in weather proof pouches until <br />final inspection. After final inspection, three sets of operation, installation, maintenance and start-up instructions shall be given to the Owner <br />for each piece of equipment per the Ca Green Building Code. <br />4. All Fire and Fire Smoke Damper installation instructions shall be made available to the inspecting authority for their review, <br />5. All penetrations through fire rated assemblies shall be fire stopped and sealed with a material that meets or exceeds the rating of the <br />assembly penetrated, Materials to be used for sealing shall be coordinated with the General Contractor to provide one bra 'd onsite. <br />6, Install all pipe and duct insulation materials per T-24 requirements, All material to be Installed shall meet CBC flame and smoke requirements per <br />note 11, <br />7. All work on this project shall conform to the following codes: <br />2016 CBC <br />2016 CPC <br />2016 CMC <br />8016 CEC <br />8016 CALIFORNIA GREEN BUILDING CODE, <br />8. All wye branches connected to a diffuser, grille or register shall have a manual volume damper installed in the wye branch. KBD's shall only be <br />used when wye branches will be installed over inaccessible ceiling areas or in the slab of the building, Dampers shall be fabricated of the same <br />gauge as the duct with 1' standoff, locking quadrant, and handle, Fasten red ribbon to handle to mark location, <br />9. All gas pipe to be schedule 40 with screwed fittings. All air conditioning/refrigeration condensate drain lines shall be schedu e 40 PVC run to <br />the an approved receptor. Set pipe on redwood blocks with 24 ga GI cover unless otherwise shown differently on drawings. <br />10. Provide smoke detectors in the supply air duct on all units when the aggregate cfm exceeds 2000 cfm of all equipment serve g a room or more <br />than one room and the room has no direct exits to the exterior. Duct smoke detectors shall be installed after the supply ;fan before any <br />branch takeoffs. When more than one unit serves a TI space and the aggregate cfm of the units serving the TI space exceeds 2000 cfm, all <br />HVAC equipment shall have duct smoke detectors. All duct smoke detectors shall be wired to shut down all units when a sin le unit alarms. <br />11 All exposed ductwork shall be GI pipe and fittings. Line all rectangular duct with Insulation with the R-vlaue listed In T-24 f r the location of <br />the duct (attic, conditioned or Outside), All duct materials from insulation to mastics Including but not limited to sheet metal,::insulation, liners, <br />plastics, rubber cements, latex, etc, shall be made of materials with a Flame spread <=25 and smoke <=50. <br />12. It is the responsibility of the Mechanical Contractor to coordinate 'the installation of his work including equipment substitute ns with the other <br />trades including but no limited to electrical, fire sprinkler, framing and plumbing. <br />13. Insulate all ductwork per the T-24 energy requirements found In the T -E4 compliance report, All ductwork shall be tested f6r leaks with a <br />maximum static pressure in the duct of 1,01, maximum leakage shall not exceed 4% of the total supply and return air volumes. <br />14. Contractor shall label all equipment with unique identification using plastic engraved plates with 1/8' tall lettering indicating t e equipment number <br />and state the areas served by the equipment, See specifications on dwgs, <br />15, All flex duct will be stretched as tight as possible and as per manufacturers listing to avoid all kinks and sagging, <br />16. AU smoke detectors shall be tested as required with an approved smoke system per the City of Stockton's standards in th. presence of the <br />inspector or fire Marshall. <br />17. All systems shall require an air balance report upon final inspection. Submit reports on NESS or NABC forms an independent certified alir <br />balance showing system has been balanced and OSA quantities set to that shown on drawings. <br />18. Condensate drain lines installed in direct or indirect sunlight shall be UV resistant CPVC or PVC pipe and shall be painted to ;protect from UV <br />radiation. <br />19. Seal all joints and seams with DP -1010 duct sealer, <br />T-24 MECH AND PLUMBING MANDATORY FEATURES <br />1. EQUIPMENT SHALL BE CERTIFIED TO MINIMUM EFFICIENCY PER SECTI❑N 1102 - SEE SCHEDULES ON M-0. <br />2. HVAC CONTROLS AND EQUIPMENT CERTIFIED PER SECTION 120.2 FOR THERMOSTATS AND DDC CONTROLS - SEE DETAILS ON MO. <br />3, SERVICE WATER HEATING SHALL COMPLY WITH SECTION 110,3 , <br />4. USE OF PILOT LIGHTS ON HVAC, GAS COOKING POOL AND SPA HEATERS PROHIBITED PER SECTION 110.5 <br />5. LAVATORIES SHALL BE SET TO MAINTAIN DISCHARGE TEMP AT 1109F ❑R LESS PER SECTION 1103 - SEE PLUMBING SCHEDULE <br />6. VENTILATION REQUIREMENTS PER 1201b,c&d M-1 AIR BALANCE <br />7. NATURAL VENTILATI❑N PER 180.1.1o,1 N/A <br />8. CONTROLS SHALL MEET REQUIREMENTS PER 122, SEE M-0 AND NOTES, <br />9. SHUT DOWN AND BACKDRAFT DAMPERS PER 128.f See schedules on M-0 <br />10, ISOLATION AREA DEVICES PER 122,g N/A <br />11. PIPE INSULATION PER 120.3,g SEE NOTES, TABLE 1203--A <br />12. REQUIREMENTS FOR DUCTS AND PLENUMS PER 124 SEE M-0, NOTES AND SPECIFICATIONS <br />13. MECHANICAL ACCEPTANCE TEST FORMS SUBMITTED AT END OF PROJECT PER SECTION 1805, 180.7 AND 120.8 - SEE T24 DRAWINGS FOR F0R2MS REQUIRIED (1-17) <br />TO BE SUBMITTED AT THE END OF THE PROJECT FOR EACH HVAC AND PLUMBING SYSTEM, AND FOR EACH HVAC AND PLUMBING PIECE OFQUIPMENT. <br />O <br />THERMOSTAT, UNIT NO. <br />JOB NO.: <br />© ❑N © <br />BYPASS, NITESTAT, CLOCK <br />- <br />CHECKED: <br />ABBREVIATIONS W/OR WO SYMBOLS <br />SHEET <br />- <br />WITH <br />W/ <br />- <br />WITH OUT <br />WO/ <br />- <br />DOWN <br />ON <br />-- <br />GALVANIZED SHEET METAL <br />G! <br />- <br />ABOVE FINISHED FLOOR <br />AFF <br />- <br />BELOW FINISHED FLOOR <br />BFF <br />- <br />BELOW FINISHED CEILING <br />BFC <br />- <br />ABOVE FINSHED CEILING <br />AFC <br />- <br />NEW DUCTWORK <br />- <br />-X-X->(- <br />DEMOLITION TO BE REMOVED <br />TBR <br />DUCTWORK EXISTING <br />(E) <br />Z <br />POINT OF CONNECTION <br />POC <br />CUT OFF POINT <br />COP <br />- <br />FURNISHED BY OTHERS <br />FBO <br />- <br />UP THROUGH ROOF <br />UTR <br />- <br />UNLESS OTHERWISE NOTED <br />UON <br />C <br />CONDENSATE, OVERFLOW <br />C. OF <br />HWS - <br />HEATING WATER SUPPLY, RETURN <br />HWS,HWR <br />- CHWS <br />CHILLED WATER SUPPLY, RETURN <br />CHWS,CHWR <br />- <br />MACHINE BOLT <br />MB <br />G,LPG <br />NATURAL GAS, LPG LINE <br />G, LPG <br />---- <br />ALL THREAD ROD <br />ATR <br />- - <br />OUTSIDE AIR <br />OSA <br />- <br />FEET PER MINUTE <br />FPM <br />D_ <br />DUCT TEMPERATURE SENSOR <br />DTS <br />- <br />FLEXIBLE DUCT CONNECTOR <br />FC <br />- <br />FLEX DUCT <br />- <br />- <br />STEAM PIPE <br />S <br />- <br />STEAM CONDENSATE <br />Sc <br />- <br />MAKEUP WATER <br />CW <br />>Q <br />SHUT OFF/BALL VALVE <br />BV <br />- <br />DUCT SMOKE DETECTOR <br />DSD <br />INVERTED P -TRAP <br />W/INSECT SCREEN O <br />INLET <br />COUNTERFLASHING W/ <br />SS DRAWBAND, SEAL AROUND <br />FLASHING AND PIPE W/SIKAFLEX <br />V CLEAR SPACE <br />BETWEEN JACK AND <br />FLUE/DUCT <br />FINISH ROOFING - ROLL <br />UP JACK AND ATTACH <br />UNDER C❑UNTERFLASHING 1 <br />ROOF JACK - 24 GA 1 <br />NAIL TO ROOF W/ MIN <br />4-2'10d NAILS <br />SEE STRUCT DWG_ <br />FOR TRUSSES <br />2x BLOCKING BY G -- <br />FLUE OR ROUND <br />EXH. DUCT <br />4-12"0 PVC COMB AIR/FLUE THRU ROOF <br />DETAI L <br />208v 30 <br />W/GR❑UND <br />FUSED DISC BY <br />ELECTRICAL <br />CONTRACTOR <br />120V 10 <br />W/GR❑UND <br />WIRE <br />LINE ECON LOGIC <br />_ NIT BOARD SUPPLIED EO USE M URBACTUREWS <br />RC RH G Yl Y2 W1 W2 C A FRMR I MANUFACTURER'S ROOF CURB <br />24 I 14' MEN Hi, IS MW CONST <br />RUCTI <br />C <br />ATTACH 18 GA VENTILATED ROOF <br />CURB TO FAN BASE W/3#10x1' <br />SM SCREWS 2 EA SIDE OF FAN BAS <br />16 GA VENTILATED ROOF CU <br />ATTACH VENTILATED <br />DSD. SD CURB TO 18 GA ROOF CUR <br />OW/3#10x1' SM SCREWS <br />AIR PRODUCTS SL 2O 2 EA SIBE OF CURB BASE <br />RC RH G Yl Y2 W1 W2 C 26 GA GI <br />PHOTELECTRIC SMOKE COUNTERFLASHI i <br />DETECTOR FILL VOID SPACE W/ <br />HONEYWELL VISI❑NPRO 8000 WITH NC RIDGID INSULATION <br />AUTOMATED DEMAND RESPONSE FINISH ROOFING UP CURB AND ATT - ATTACH <br />ROLL <br />FUNCTION SERIES Y AND W NAILER <br />TERMINALS TO MATCH UNITS 3/13'0x3-1/2' LAG BOLT - EMBED <br />FIREX REMOTE 3' MIM, PLACE 48'OC <br />TEST SWITCH SEE STRUCT DWqS <br />AND LED'S GRN LED d FOR TRUSSES <br />OHONEYWELL C7232C10DA RED LED O 4x BLOCKING BY <br />WORN/STROBE o ® I -HR SHEET ROCK (SR)SHAFT <br />C02 SENSOR, WALL RESET O SEE ARCH DWGS <br />RC 0 IOVDC MOUNTED WITH 24 AIR PRODUCTS IS GA GREASE TIGHT, D <br />POWER MS-RH/KA/P/AT AIRGAP TO INSIDE SR <br />6 THERMOSTAT 5 FAN CURB MOUNT <br />MQ DETAIL MO DETAIL <br />0 <br />m <br />AC - <br />ATTACH 6' MINERAL WOOL <br />SOUND BLANKETS TO BOTTOM <br />OF UNIT TO DEADEN SOUND <br />GASKET - USE MANUFACTURER'S <br />SUPPLIED WITH CURB <br />MANUFACTURER'S ROOF CURB <br />14' MIN HT, 18 MIN CONSTRUCTION <br />12 GA ANGLE CLIP - ATTACH <br />TO CURB W/3#10x1' SM SCREWS <br />TO UNIT W/#10x1' SM SCREWS <br />CLIP TO B£ 6'MIN LONG, 2 £A <br />LONG SIDE OF UNIT AT CORNERS <br />26 GA GI <br />COUNTERFLASHING <br />FILL CURB VOID SPACE <br />W/ RIGID INSULATION <br />AND UNDER UNIT WITH <br />ROCK WOOL BATT <br />INSULATION <br />FINISH ROOFING - ROLL <br />UP CURB AND ATTACH T9 __ <br />NAILER <br />3/8'0x3-1/2' LAG BOLT - EMBED <br />3' MIN, PLACE 48'OC <br />SEE STRUCT DWGS <br />FOR TRUSSES <br />4x BLOCKING BY GC SEAL AIRTIGH <br />SHEET METAL DUCT <br />W/1' 6.2R LINER <br />AC_ <br />D ETAI L <br />RB MOUNT <br />DUCT OPENING <br />F --3-16d NAILS <br />DUCT ON ROOF -SEE <br />SPECIFICATIONS FOR INSULATION-- -- <br />GASKET - 1/4' NEOPRENE <br />18 GA WELDED CURB W/2x NAILER <br />14' MIN HT, PITCH TO MATCH R❑QFC <br />ATTACH TO CURB W/4#10x1' \ <br />SM SCREWS 1 EA <br />LONG SIDE OF UNIT AT CORNERS <br />2x WOOD NAILER <br />26 GA GI <br />C❑UNTERFLASHING <br />FILL VOID SPACE W/ <br />RIGID INSULATI❑N <br />FINISH ROOFING - ROLL <br />UP CURB AND ATTACH <br />NAILER <br />CANT STRIP BY R❑OFEF� <br />1/4'Ox3-1/2' LAG BOLT - EMBED <br />3' MIN, PLACE 2 EA SIDE <br />(E)2x6 FRAMING <br />3-16d NAILS <br />2x BLOCKING BY <br />SHEET METAL DUCT W/ SEAL AIRT <br />INSULATION THRU ROOF - <br />DUCT CURB MOUNT <br />EIAIL <br />NECK SI <br />ED <br />CR -1 R6 PLENUM <br />4-#12GA CEILING WIRES TO <br />SUPPORT 1' THICK DUCT BOARD <br />ELBOW AND REGISTER. ATTACH <br />REGISTER TO T -BAR W/(2) <br />#7x1/2' S/M SCREWS THRU <br />OUTLET FLANGE TO GRID RUNNER <br />ON ❑PPOSIT€ CORNER <br />N <br />N <br />2'x24 GA GI DUCT SUPPORT STRAP <br />WITHIN 2' OF REGISTER - MIN FLEX <br />DUCT LENGTH IS 3'2' SO THAT ALL <br />DUCTS SHALL DISPLAY THE DUCT <br />SIZE AND INSULATI❑N VALUE AND <br />MAX LENGTH IS 10' FOR ❑SHPD, 5'0' <br />FOR ALL OTHERS. ALL ELBOW <br />RADIUS'S TO BE 1.5 DUCT DIAMETER, <br />FLEX DUCT TURNS TO BE 2.0 DUCT <br />MAMETER <br />T -BAR REGISTER <br />DETAIL <br />T CEILING SYSTEM <br />2 OUTLET - WTC10# <br />SM SCREW OR #12 <br />SLACK WIRE ON <br />POSITE CORNERS <br />TE: <br />CURE CEILING OUTLET TO S.A.T, <br />[LING GRID WITH (2) #10x1/2' S/M <br />REWS THRU OUTLET FLANGE TO <br />ID RUNNER AND AT DIAGONAL <br />RNERS INSTALL (2) #12 GA. SLACK <br />RES ATTACHED TO STRUCTURE <br />7VE USING CLOSED LOOP EYEBOLTS, <br />WIRE AND SCREWS ARE REQUIRED ON <br />ALL REGISTERS, <br />2018-025"5 <br />GDMD ENGINEERING, INC <br />Mechanical and Safety Engineers <br />212 W Pine St, Ste 4 <br />Lodi, Ca 95242 <br />Ph 209-367-0899 <br />Fax 209-367-0898 <br />E-mail :gdmdengrinc@sbcglobal, net <br />api COPYRIGHT 2017 <br />REV'SIONS <br />THIS DOCUMENT, AND THE IDEAS AND DESIGNS <br />INCORPORATED HERFIN, AS AN INSTRUMENT OF <br />PROFESSIONAL SERVICE, IS THE PROPFRTY OF <br />"api' AND IS NOT TO BE USED, IN WHOLF OR IN <br />PART, FOR ANY OTHFR PROJECT WITHOUT <br />WRITTEN AUTHORIZATION. <br />w <br />F- <br />0 <br />z <br />06 <br />Q <br />n <br />LU <br />J <br />n <br />fU <br />U <br />In <br />U <br />z <br />U <br />LL! <br />PLANNING ■ ■ ■ <br />ARCHITECTURE ■ ■ <br />ARCHITECTURE PLUS INC. <br />4335-B NORTH STAR WAY <br />MODESTO, CA 95356 <br />ph. 209.577.4661 <br />N. 209.577.0213 <br />www.apiarc.com <br />FRANK C. BOOTS <br />JOSEPH L. SMITH <br />RODNEY C. ALONZO <br />ARCHITECTS <br />.J <br />W <br />N <br />TZ z <br />i. � <br />V� <br />W W <br />Z <br />W <br />pNAL <br />OAF. G. Dq Qi <br />r <br />Lf) REN: 6�ik i8 <br />�CHA \ r_' � <br />OF CPL\ <br />DATE : <br />JANUARY 2018 <br />JOB NO.: <br />\(E)2x6'S 24' <br />❑C <br />�N)2x6 <br />DRAWN: <br />(E)4x R©❑ <br />PURL❑INS <br />DUCT ON ROOF -SEE <br />SPECIFICATIONS FOR INSULATION-- -- <br />GASKET - 1/4' NEOPRENE <br />18 GA WELDED CURB W/2x NAILER <br />14' MIN HT, PITCH TO MATCH R❑QFC <br />ATTACH TO CURB W/4#10x1' \ <br />SM SCREWS 1 EA <br />LONG SIDE OF UNIT AT CORNERS <br />2x WOOD NAILER <br />26 GA GI <br />C❑UNTERFLASHING <br />FILL VOID SPACE W/ <br />RIGID INSULATI❑N <br />FINISH ROOFING - ROLL <br />UP CURB AND ATTACH <br />NAILER <br />CANT STRIP BY R❑OFEF� <br />1/4'Ox3-1/2' LAG BOLT - EMBED <br />3' MIN, PLACE 2 EA SIDE <br />(E)2x6 FRAMING <br />3-16d NAILS <br />2x BLOCKING BY <br />SHEET METAL DUCT W/ SEAL AIRT <br />INSULATION THRU ROOF - <br />DUCT CURB MOUNT <br />EIAIL <br />NECK SI <br />ED <br />CR -1 R6 PLENUM <br />4-#12GA CEILING WIRES TO <br />SUPPORT 1' THICK DUCT BOARD <br />ELBOW AND REGISTER. ATTACH <br />REGISTER TO T -BAR W/(2) <br />#7x1/2' S/M SCREWS THRU <br />OUTLET FLANGE TO GRID RUNNER <br />ON ❑PPOSIT€ CORNER <br />N <br />N <br />2'x24 GA GI DUCT SUPPORT STRAP <br />WITHIN 2' OF REGISTER - MIN FLEX <br />DUCT LENGTH IS 3'2' SO THAT ALL <br />DUCTS SHALL DISPLAY THE DUCT <br />SIZE AND INSULATI❑N VALUE AND <br />MAX LENGTH IS 10' FOR ❑SHPD, 5'0' <br />FOR ALL OTHERS. ALL ELBOW <br />RADIUS'S TO BE 1.5 DUCT DIAMETER, <br />FLEX DUCT TURNS TO BE 2.0 DUCT <br />MAMETER <br />T -BAR REGISTER <br />DETAIL <br />T CEILING SYSTEM <br />2 OUTLET - WTC10# <br />SM SCREW OR #12 <br />SLACK WIRE ON <br />POSITE CORNERS <br />TE: <br />CURE CEILING OUTLET TO S.A.T, <br />[LING GRID WITH (2) #10x1/2' S/M <br />REWS THRU OUTLET FLANGE TO <br />ID RUNNER AND AT DIAGONAL <br />RNERS INSTALL (2) #12 GA. SLACK <br />RES ATTACHED TO STRUCTURE <br />7VE USING CLOSED LOOP EYEBOLTS, <br />WIRE AND SCREWS ARE REQUIRED ON <br />ALL REGISTERS, <br />2018-025"5 <br />GDMD ENGINEERING, INC <br />Mechanical and Safety Engineers <br />212 W Pine St, Ste 4 <br />Lodi, Ca 95242 <br />Ph 209-367-0899 <br />Fax 209-367-0898 <br />E-mail :gdmdengrinc@sbcglobal, net <br />api COPYRIGHT 2017 <br />REV'SIONS <br />THIS DOCUMENT, AND THE IDEAS AND DESIGNS <br />INCORPORATED HERFIN, AS AN INSTRUMENT OF <br />PROFESSIONAL SERVICE, IS THE PROPFRTY OF <br />"api' AND IS NOT TO BE USED, IN WHOLF OR IN <br />PART, FOR ANY OTHFR PROJECT WITHOUT <br />WRITTEN AUTHORIZATION. <br />w <br />F- <br />0 <br />z <br />06 <br />Q <br />n <br />LU <br />J <br />n <br />fU <br />U <br />In <br />U <br />z <br />U <br />LL! <br />PLANNING ■ ■ ■ <br />ARCHITECTURE ■ ■ <br />ARCHITECTURE PLUS INC. <br />4335-B NORTH STAR WAY <br />MODESTO, CA 95356 <br />ph. 209.577.4661 <br />N. 209.577.0213 <br />www.apiarc.com <br />FRANK C. BOOTS <br />JOSEPH L. SMITH <br />RODNEY C. ALONZO <br />ARCHITECTS <br />.J <br />W <br />N <br />TZ z <br />i. � <br />V� <br />W W <br />Z <br />W <br />pNAL <br />OAF. G. Dq Qi <br />r <br />Lf) REN: 6�ik i8 <br />�CHA \ r_' � <br />OF CPL\ <br />DATE : <br />JANUARY 2018 <br />JOB NO.: <br />17-057 <br />DRAWN: <br />A. BARROZO <br />CHECKED: <br />G. DAVIS <br />SHEET <br />MO <br />U <br />a <br />a <br />0 <br />00 <br />