Laserfiche WebLink
GYP. BOARD MOUNTED AT STUD WALL HEAVY DUTY COVER MAY EXTEND AS NOTES: <br /> FINISH FLOOR WASTE OR VENT <br /> r— 1. WHERE VENTS CONNECT TO A HORIZONTAL DRAINAGE PIPE, EACH VENT PIPE SHALL HAVE ITS INVERT <br /> I 1 I UNI-STRUT # P-1000 CHANNEL, PROVIDE ONE CONCRETE SLAB <br /> f BRONZE TAKEN OFF ABOVE THE DRAINAGE CENTER LINES OF SUCH PIPE DOWNSTREAM OF THE TRAP BEING <br /> CLEAN OUT SERVED PER CPC SECTION 905.2 <br /> I I CHANNEL WITH STRAPS EVERY 10 FEET. TYPICAL PLUG <br /> AND 2 FEET FROM CORNERS. ADJUSTABLE COLLAR <br /> 4 b BRONZE PLUG 2. VENTS LESS THAN SIX (6) INCHES (152 MM) ABOVE THE FLOOD LEVEL RIM OF THE FIXTURE SHALL <br /> BE INSTALLED WITH APPROVED DRAINAGE FITTINGS, MATERIAL AND GRADE TO THE DRAIN PER CPC <br /> COUNTERSUNK SECTION 905.3. <br /> SCREW <br /> I ,�UNI—STRUT STRAP (TYPICAL)SIZED TO I if i III I 1. I11 <br /> TiGHTENEDPCENTERIPE HSTRAPS TOGCLAMPNUT FPIPEYAT 3. �RT�PERMITTED TO FLAT-VENT UNLESS STRUCTURAL CONDITIONS PROHIBIT TAKING OFF AT 45' OR Roy ASSOCIATES <br /> ffli_ PIPES CENTER OF UN{STRUT POLISHED S.S. VENT TAKE OFF ABOVE CONSULTING ENGINEERS <br /> 1 <br /> ACCESS COVER CENTER <br /> LIE E OF <br /> PIP <br /> I I APPROVED 1/8 BEND Q <br /> NO-HUs SOIL PIPE. p 39510 PASEO PADRE PKWY, <br /> _ I ICONNECTOR SUITE 250 <br /> TYPICAL ONE OF THREE - Ya" SELF TAPPING (TYPICAL) CALIFORNIA 94538 <br /> I I SCREWS AT 32" O.C. TO METAL STUDS Y BRANCH \ / ��, FREMONT,(510) 794-8091 <br /> I THROUGH UNI-STRUT SOIL PIPE, <br /> PROVIDE h" HILTI KWIK BOLT ANCHOR BOLT IN WASTE LINE 2 Fax: (510) 794-7250 <br /> � CONCRETE OR JI�" LAG SCREW IN WOOD WITH <br /> FLOW LENGTH TO SUIT Email: rgy@royassociates.com <br /> MINIMUM 2 Y" PENETRATION. TYPICAL 2 PER EACH <br /> UNISTRUT TEST 50% AT 1944 LB. PULL OUT. This <br /> drawing embodies Woos, designs, <br /> arrangements, plans and specifications that are <br /> NOTES: NOTE: property to Roy Associates and which were <br /> designed, created, evolved and developed for use <br /> VENT TAKE OFF soleN in connection with the specified project for <br /> 1. PROVIDE PIPE SUPPORT BLOCK SPACING PER CPC TABLE 313.1, PIPE HANGER & SUPPORT. ADEQUATE PROTECTION SHALL BE PROVIDED AGAINST BREAKAGE FOR PIPING PASSING THROUGH R°�ti�is be use Ro transfer of or affected by delWery"� <br /> 2. GAS PIPING SUPPORT BLOCK SPACING PER CPC TABLE 1210.2.4.1, SUPPORT OF PIPING. CONCRETE FLOORS IN ACCORDANCE WITH CPC SECTION 313.2, AND SLEEVES SHALL BE PROVIDED DRAIN PIPE hereof,And except upon written permission of Roy <br /> AsswW as this drawing Is not to be disclosed to <br /> AS PROTECTION FOR PIPING PASSING THROUGH CONCRETE/MASONRY WEALLS PER CPG 313.10 others. reproduced or copied In whole or in part <br /> or used in the fabrication. permitting, and <br /> PIPE SUPPORT ON WALL DETAIL WALL AND FLOOR CLEANOUT VENT TAKE-OFF DETAIL `°d� oidofeoy Assocate °�'use <br /> foundations, <br /> other than Roy Associates specific use abne. <br /> C9- These drawings and use of can be revoked at any <br /> ;--05 . 1 NOT TO SCALE NOT TO SCALE NOT TO SCALE timeby <br /> nd N g DeAssociates partment�dlerfaaannd <br /> without Cause. <br /> T INSTALL WATER HAMMER ARRESTOR NOTES. 1/2 GRATE W/ OPEN <br /> INSTALL WATER 1 " Copyright Roy Aesoclates <br /> HAMMER ARRESTOR 1 JUST BEFORE LAST FIXTURE ON 1 2 FOR DRAIN PIPES <br /> ON ALL FIXTURES 1 I BRANCH LINE CONDENSATE DRAINAGE FROM THE MECHANICAL UNIT / <br /> WITH QUICK CLOSING I SHALL DISCHARGE INTO LAVATORY TILPIECE OR FLOOR SINK SET ON TOP OF QROF ESSIO <br /> VALVES. OR MOP SINK IN SAME SPACE AS SERVED BY FAN AI)�PTER FLOOR SINK FLUSH FLOOR SINK. U.N.Q. ��o yPNPT Ror V <br /> 3/4"0 CONDENSAE WATER SEALI= - <br /> INDIRECT <br /> WITH FINISHED FLOOR <br /> INSTALL AN ADDITIONAL WATER DRAIN PIPE (U.O.N.) WASTE <br /> HAMMER ARRESTOR IF THE BRANCH PVC OR COPPER TYPE 'L' VENT HVAC UNIT FINISHED FLOOR NO. M19038 <br /> SENGLE OR UNE IS GREATER THAN 20' LONG. COIL DRAIN PAN LINE 09-30-20 <br /> � TO DRAIN — — MIN. 1" AIR <br /> DOUBLEFIXTURE GAP s <br /> MULTIPLE FIXTURES VTR SLOPE 1/4" PER FT. z 9 'tFCyA1dIGP� �7 <br /> m (SEE NOTE ABOVE} <br /> I OF CA0 <br /> PDI PIPE FUXTURE WATER SUPPLY FIXTURE UNIT (WSFU) GRATE VIEW <br /> SIZE SIZE UNIT LOAD FIXTURE COLD HOT VENT LINE <br /> A 1" 1-11 VALVE WATER CL05ET 5 -- I WALL I I 1/2" GRATE WITH OPEN <br /> B 3/" 12-32 URINAL 4 -- I r I I 3/4 FOR DRAIN PIPE <br /> IMIN. 3/4" COND. DRAIN I SET ON TOP OF <br /> C 1" 33-60 LAVATORY / SINK 1.5 1.5 I AIR GAP I PIPE DRIP IMOP SINK WITH AIR GAP INTO <br /> FLOOR SINK U.N.O <br /> D 1 A" 61-113 JANITOR'S SINK 3 3 3/4"0 COND.I I I TAIL PIECE TO P-TRAP N <br /> E 1 Y2" 114-154 LAVATORY OR NT ON <br /> NFLOOR SIN AN <br /> PIPE DRIP AND VENTED WASTE <br /> F 2" 154-330 SINK WITH AIR GAP <br /> L E�7 — <br /> or—1i SLIP-TEE ® MOP SINK FLOOR SINK Q <br /> TAILPIECE <br /> NOTE: <br /> 1. WATER HAMMER ARRESTERS SHALL BE HAVE PISTON AND 0-RING CONSTRUCTION WITH PDI #WH-201, Ac <br /> ASSE # 1010 AND ANSI # A112.26.1M CERTIFICATION. INSTALL IN HORIZONTAL OR VERTICAL POSITION, Tq SANITARY SEWER TO SANITARY SEWER GRATE VIEW w <br /> BUT NEVER UPSIDE DOWN. SIZE THE UNITS AS SHOWN PER THE TABLES SHOWN ABOVE. -----TO SANITARY SEWER 4 <br /> WATER HAMMER ARRESTOR SIZING DETAIL CONDENSATE DRAIN CONNECTION FLOOR SINK DETAIL o `� <br /> NOT TO SCALE �� NOT TO SCALET <br /> NOT 0 SCALE 1r� � v <br /> FROM GAS SUPPLY <br /> PIPING SYSTEM <br /> SEALANT <br /> 1"x1 4" DRAW BAND Q <br /> GALVALNIZE METAL FLASHING - <br /> 2x MEMBERS <br /> SINGLE PLY MEMBRANE <br /> 4" CANT <br /> GAS LINE � <br /> EXISTING TO UNIT EQUIPMENT GAS VALVE <br /> BUILD-UP ROOF I MANUAL SHUT-OFF <br /> --•••�•----{--6" AROUND CURB H <br /> L-. E} ROOF <br /> I <br /> CONSTRUCTION DATE ISSUE FOR BY <br /> 5-01-19 100 DEMO PLAN SR <br /> DIRT/WATER VAPOR 07-02-19 CITY/HEALTH SUBMITTAL SR <br /> DRIP LEG <br /> PIPE <br /> GAS PIPE CAP <br /> PIPE PENETRATION ROOF DETAIL GAS PIPING CONNECTION <br /> ==;;—C7 3 <br /> NOT TO SCALE NOT TO SCALE SHEET CONTENT: <br /> PLUMBING <br /> , w DETAILS <br /> 1/2"o MACHINE.BOLT <br /> EXHAUST HOOD <br /> ANGLE GAS DROP - --�� <br /> STANDARD <br /> CUT WASHER <br /> UNION & ELBOW <br /> PROVIDED ON FLEX SCALE: AS INDICATED <br /> HANGER ROD, 3/8"0 HOSE <br /> GAS APPLWNCE DATE: 07-02-19 <br /> ON CASTERS DRAWN BY: VS/WA/JB/GS <br /> SUPERSTRUT CT-727 QUICK DISCONNECT CHECKED BY: SR/KS/FP/SP <br /> OR EQUAL <br /> PIPE L FLEX GAS LINE AGA SHEET No.: <br /> L LISTED 1' DIA x <br /> I 48" LG <br /> ! I I <br /> BILI <br /> SHIELD BETWEEN PIPE DRIP LEG FIN. FLOOR P3 . 0 <br /> AND HANGER <br /> SHEET 30 OF 33 <br /> PIPE SUPPORT DETAIL TYP. GAS CONNECTION FOR SOUP. L PROJECT No.: — 19--•020 <br /> NOT TO SCALE NOT TO SCALE <br />