i
<br /> SAdditional field monitoring data to be collected are described below
<br />' Table B - Field Groundwater, Soil Vapor, and Ambient Air Monitoring PIan
<br /> Parameter Wells Monitoring Method Monitoring Freguency and Notes
<br />' Injection pressure IPIA,IIP 1B, IP2A,IP213, Pressure gauge m At 5 minute intervals for the first 30
<br /> IP3A,IP3B trailer minutes of injection, then 15 minute
<br /> intervals thereafter for the first 4
<br /> hours of injection Weekly when
<br /> system is in continuous operation
<br /> Injection volume and IPIA,IP 113,1P2A,IP2B, Totalizing meter in At 5 minute intervals for the fust 30
<br /> flow rates IP3A,IP3B trailer minutes of injection,then 15 minute
<br /> intervals thereafter for the first 4
<br /> hours of mjection Weekly when
<br /> system is in continuous operation
<br /> DO,ORP,EC,pH, IP1A,IP1B,MA,IP213, YSI meter Prior to start of operation, 1 hour
<br /> and temperature IP3A, IP3B, SW 1,SW2, after injection and every other week
<br /> RWI,RW2,IW1,V3, V4, thereafter
<br /> MW4,MWS,MW7,
<br /> WB-MW2
<br /> Depth to water SWI, SW2,RWI,RW2, Water level meter Prior to start of operation and
<br /> IW I,V3,V4,MW4, periodically thereafter
<br /> MWS,MW7,UVB-MW2
<br /> Hydrocarbon MW2,MW3,MW6, and PID Prior to and 30 minute intervals for
<br /> concentrations in soil MW5 at manifold of SVE the first 4 hours of injection and
<br /> vapor system weekly thereafter when the system
<br /> is in continuous operation
<br /> Ozone in soil vapor MW2,MW3, and MW6 at PortaSensor 11(or Prior to and 30 minute intervals for
<br /> manifold of SVE system similar model) the first 4 hours of injection Weekly
<br /> (and MW5 and RW 1 if thereafter when the system is in
<br /> warranted) continuous operation
<br /> Ozone/hydrocarbons As marked on Figure 2 PortaSensor II(or Prior to and 30 minute intervals for
<br /> in ambient air similar model)and the fust 4 hours of injection Weekly
<br /> PID thereafter when the system is in
<br /> continuous operation
<br /> Pressure influence RW 1,RW2,IW 1,MW4, Magnehelic or digital Prior to and 30 mmute intervals for
<br /> MW7,UVB-MW2 nanometer the first 4 hours of injection Weekly
<br /> thereafter when the system is in
<br /> continuous operation
<br /> G 1Pro)ects5739421MASTERIWP1WP07OnOzonc Infection Pilot Tcst Work Plan doc p