(11/87) <br /> F. Sample Shipment <br /> * Describe how samples will be packaged and shipped. Include the method of <br /> shipment and the time schedule of shipment relative to sample collection. <br /> Do not ship samples as baggage on passenger planes. It is against Department <br /> of Transportation (D0T) regulations. <br /> * If medium concentration samples (>loppm) will be shipped, special packaging <br /> and D0T labelling requirements must be described. <br /> * All sample shipments must be reported to the RSCC within one day after shipment. <br /> Friday shipment/Saturday laboratory receipt of samples must be coordinated <br /> with the RSCC by noon on Friday. <br /> * Appendix E includes analytical and CLP contract hold times for RAS and cannon <br /> SAS parameters. These hold times should be considered when developing sampling <br /> and shipping schedules. (See also Appendix D. ) <br /> G. Sample Docunentation <br /> * Address the use of all paperwork including field notebooks, Organic and <br /> Inorganic Traffic Reports, SAS Packing Lists, and Chain of Custody forms and <br /> seals in the sampling effort (see Appendix F) . Include instructions on <br /> properly filling out the paperwork. Describe sample bottle labeling. <br /> * At the end of each sampling event the samplers will be required to submit to <br /> the Region 9 RSCC a summary of all lab QA/QC samples collected during the <br /> sampling event, and a summary of any sampling problems encountered in the <br /> field that might affect the lab analyses or data quality. A form for this <br /> reportwill be provided by the RSCC. For long term projects, this report <br /> will be required monthly. <br /> H. Quality Assurance <br /> 1. Replicates <br /> * Replicates are a check on the laboratory and field procedures. Collect 1 <br /> sample per week or 10%/parameter/matrix/lab/site whichever is greater. <br /> Replicates should be from sampling points which are known or suspected to <br /> be contaminated. <br /> * Replicates should be for samples which have a complete parameter suite. <br /> Identify the sampling point, if known, whic7 will have replicate samples. <br /> The replicate should be collected, numbered, packaged, and sealed in the <br /> same manner as the other samples. <br /> * Describe hoer replicates will be collected. The collection procedure <br /> must insure that the replicates are hanogeneous, comparable samples. <br /> * Replicate samples must be identified on the Region 9 copy of the sample <br /> paperwork, not the lab copy. The sample is a blind replicate for the lab. <br />