COMPLIANCE INFO_1985-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
515
>
2300 - Underground Storage Tank Program
>
PR0231400
>
COMPLIANCE INFO_1985-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:32 AM
Creation date
4/27/2020 12:23:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985-2005
RECORD_ID
PR0231400
PE
2361
FACILITY_ID
FA0003539
FACILITY_NAME
S B GAS & MARKET
STREET_NUMBER
515
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23309031
CURRENT_STATUS
01
SITE_LOCATION
515 W ELEVENTH ST STE 301
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231400_515 W ELEVENTH_1985-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
553
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Site Preparation and In lation Instructions <br />FITLS-350 <br />UST MonitorinEWstem <br />Figure 5. Magnetostrictive Probe Installation <br />Requirements. <br />In addition, make sure there will be enough clearance <br />between the top of the installed riser cap and manhole <br />cover to allow room for the two -wire probe cable to <br />protrude from the cap. <br />3. Install a standard adaptor ring and riser cap on the <br />riser pipe. <br />NOTE: The cap should be a locking cap, "Evertite" <br />or equivalent, with a standard ring adaptor. The cap <br />must be drilled and tapped to receive the furnished <br />cable grip (see Section 5.13 and Section 6.13). <br />Kits consisting of a 4 -inch cap, adaptor ring and plug <br />for the cap are available from Veeder-Root. For each <br />probe riser, order one Kit Number: 312020-952. <br />B. INTERSTITIAL LIQUID SENSOR RISER PIPE <br />INSTALLATION. <br />(See Figure 6, "Liquid Sensor Installation Requirements— <br />Steel Tanks" and Figure 7, "Liquid Sensor Installation <br />Requirements—Fiberglass Tanks"). <br />•' NOTE: If the tank is at atilt, install the sensor at the <br />lower end of the tank. <br />1. Standard procedures for installing a fill pipe can be used. <br />Instructions are based on a 2 -inch riser pipe. <br />1101 NOTE: Fiberglass tanks require a 4" diameter riser <br />pipe. <br />6 <br />Figure 6. Liquid Sensor Installation Requirements – <br />Steel Tanks. <br />1C" MINIMUM DIA <br />4 MANNHUM DIA <br />1 OLE <br />CONCRETE SLAB <br />OR PACKED EARTH <br />PER NFPA BL <br />2COLD <br />SUPPLIED <br />GRIP SEALS <br />WITH PROBE <br />16" MIN <br />WEN TH RPROOF <br />U CTION BOf WITH <br />INCH N <br />`_I16 CUBIC INCH D <br />EICUMI <br />EPDXYSEAL <br />- MIFIA <br />2 ORD GRIP SEALS <br />SEE <br />2 WIRE CABLE <br />-NOTE <br />SUPPLIED WITH <br />RISER DIMENSION <br />PROBE <br />SHOULD BE 18" TO <br />THE BOTTOM OF <br />a 00" A PIPE <br />THE RISER CAP. <br />FPDXV SEAL <br />PER NFPA <br />SPEC <br />TO PROBE <br />LE <br />SCHEDUD6 <br />MAGNETOSTRICTIVE <br />TANK <br />LEADER <br />PROBE <br />Note: Increase this minimum dimension it the tank <br />— a.. Ow. <br />RISER <br />diameter does not match the probe length. <br />(Example: A T6" dia. tank will use an 6' <br />FIBERGLASS TANK <br />SENSOR <br />INSET <br />probe. The extra probe height will be lodged <br />SENSOR SWITCH <br />B ..P,TANK <br />OE SENSOR SWITCH <br />nT 90 TTOM OE TANK <br />in the riser pipe, which must be 6" longer <br />than the minimum in order to provide room.) <br />Figure 5. Magnetostrictive Probe Installation <br />Requirements. <br />In addition, make sure there will be enough clearance <br />between the top of the installed riser cap and manhole <br />cover to allow room for the two -wire probe cable to <br />protrude from the cap. <br />3. Install a standard adaptor ring and riser cap on the <br />riser pipe. <br />NOTE: The cap should be a locking cap, "Evertite" <br />or equivalent, with a standard ring adaptor. The cap <br />must be drilled and tapped to receive the furnished <br />cable grip (see Section 5.13 and Section 6.13). <br />Kits consisting of a 4 -inch cap, adaptor ring and plug <br />for the cap are available from Veeder-Root. For each <br />probe riser, order one Kit Number: 312020-952. <br />B. INTERSTITIAL LIQUID SENSOR RISER PIPE <br />INSTALLATION. <br />(See Figure 6, "Liquid Sensor Installation Requirements— <br />Steel Tanks" and Figure 7, "Liquid Sensor Installation <br />Requirements—Fiberglass Tanks"). <br />•' NOTE: If the tank is at atilt, install the sensor at the <br />lower end of the tank. <br />1. Standard procedures for installing a fill pipe can be used. <br />Instructions are based on a 2 -inch riser pipe. <br />1101 NOTE: Fiberglass tanks require a 4" diameter riser <br />pipe. <br />6 <br />Figure 6. Liquid Sensor Installation Requirements – <br />Steel Tanks. <br />Figure 7. Liquid Sensor Installation Requirements – <br />Fiberglass Tanks. <br />1C" MINIMUM DIA <br />MANHOLE <br />2 ORD GRIP SEALS <br />SUPPLIED WITH SENSOR <br />WEATHERPROOF <br />JUNCTION BOX WITH <br />1INCH NET TT CS <br />1162CUBIC INCH <br />– IDM, <br />FPDXV SEAL <br />PER NFPA <br />SPEC <br />TO PROBE <br />JUNCTION BOX <br />LEADER <br />CABLE <br />— a.. Ow. <br />RISER <br />BOTTOM01 I5ER PIPE <br />FIBERGLASS TANK <br />SENSOR <br />INSET <br />SENSOR SWITCH <br />B ..P,TANK <br />OE SENSOR SWITCH <br />nT 90 TTOM OE TANK <br />Figure 7. Liquid Sensor Installation Requirements – <br />Fiberglass Tanks. <br />
The URL can be used to link to this page
Your browser does not support the video tag.