My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1985-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
515
>
2300 - Underground Storage Tank Program
>
PR0231400
>
COMPLIANCE INFO_1985-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:32 AM
Creation date
4/27/2020 12:23:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985-2005
RECORD_ID
PR0231400
PE
2361
FACILITY_ID
FA0003539
FACILITY_NAME
S B GAS & MARKET
STREET_NUMBER
515
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23309031
CURRENT_STATUS
01
SITE_LOCATION
515 W ELEVENTH ST STE 301
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231400_515 W ELEVENTH_1985-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
553
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br />Typical Sensor and Probe Junction Boxes: <br />Manufacturer: Appleton Electric Co. <br />1701 W. Wellington Avenue <br />Chicago, IL 60657 <br />Tel: (312) 327-7200 <br />Description <br />Catalog Number <br />Quantity <br />Junction Box <br />JBDX-75 <br />1 <br />Cover, Junction Box <br />JBK-B <br />1 <br />Gasket, Junction Box <br />JB -GK -V <br />1 <br />Manufacturer: Crouse -Hinds Co. <br />Syracuse, NY 13221 <br />Tel: (316) 477-7000 <br />Description <br />Catalog Number <br />Quantity <br />Junction Box <br />GRFX-139 <br />1 <br />Cover, Junction Box <br />GRF-10 <br />1 <br />Gasket, Junction Box <br />GASK-643 <br />1 <br />G. MANHOLE INSTALLATION. <br />11,E NOTE: Ensure that there is a sufficient amount of <br />gravel under each manhole for proper drainage. <br />At each probe and sensor location, install a 14 -inch mini- <br />mum diameter approved manhole according to the <br />manufacturer's instructions. Offset the probe or sensor <br />riser pipes within the manholes for ease of junction box <br />installation and wiring. Leave enough space between the <br />junction box and manhole liner so that the junction box <br />can be removed if necessary. <br />H. INTRINSICALLY SAFE WIRING INSTALLATION. <br />(See Figures 9a and 9b, "Typical TLS -350 System Wiring <br />Diagrams"). <br />To the installer: Read and carefully adhere to the instruc- <br />tions in the following warnings during intrinsically <br />safe -wire (field wire) installation! <br />mill WARNING: IMPROPER SYSTEM OPERATION <br />COULD RESULT IN UNDETECTED POTEN- <br />TIAL ENVIRONMENTAL AND HEALTH HAZ- <br />ARDS IF THE PROBE- OR SENSOR -TO -MONI- <br />TOR WIRE RUNS EXCEED 1000 FEET. RUNS <br />OVER 1000 FEET ARE NOT UL ACCEPTED <br />FOR THIS APPLICATION. PROBE- AND <br />SENSOR -TO -MONITOR WIRES MUST NOT <br />EXCEED 1000 FEET. <br />WARNING: EXPLOSION COULD OCCUR IF <br />OTHER WIRES SHARE CONDUITS OR <br />TROUGHS WITH PROBE OR SENSOR WIR- <br />ING. CONDUITS AND WIRING TROUGHS <br />FROM TLS -350 PROBES AND SENSORS MUST <br />NOT CONTAIN ANY OTHER WIRES. <br />Site Preparation a Installation Instructions <br />TLS -1W UST Monitoring System 11 <br />FAILURE TO COMPLY WITH THESE WARN- <br />INGS COULD RESULT IN DEATH, SERIOUS <br />PERSONAL INJURY, PROPERTY LOSS AND <br />EQUIPMENT DAMAGE. <br />All wires must be of a type designed for use in the presence <br />of gasoline and oil, and must be between AWG 18 and <br />AWG 14. The conduit must be properly sealed in accor- <br />dance with the National Electrical Code (NFPA 70) and <br />the Automotive and Marine Service Station Code (NFPA <br />30A) since they pass from a Class 1, Division I or Division <br />II area into a nonhazardous area. <br />16 CAUTION: IT IS CRITICAL THAT YOU IDENTIFY <br />AND MAINTAIN THE RELATIONSHIP OF PROBE <br />AND SENSOR LOCATIONS AND THEIR WIRES <br />TO THEIR POSITIONS ON THE PROBE OR SEN- <br />SOR CONNECTORS. FAILURE TO DO SO COULD <br />RESULT IN THE IMPROPER IDENTIFICATION <br />OF A LEAK LOCATION OR LEAK TYPE. APPEN- <br />DIX A PROVIDES A FORM TO RECORD THE <br />COLOR CODING OR LABELING METHOD USED <br />TO IDENTIFY THE WIRING SCHEME. <br />1. Two -Wire Probe and Sensor Wiring. <br />Pull two conductors of color -coded, THWN AWG 14-18 <br />stranded copper wire between the TLS -350 monitor <br />and the junction box at each probe and sensor loca- <br />tion. <br />Since the wires for multiple probes and sensors may <br />enter the TLS -350 monitor through a single conduit, <br />be sure to use a different color code for each wire or <br />individually mark each wire! <br />2. Three -Wire Sensor Wiring. <br />Pull three conductors of color -coded, THWN AWG <br />14-18 stranded copper wire between the TLS -350 <br />monitor and the junction box at each monitoring well <br />location. <br />Since the wires for multiple sensors may enter the <br />TLS -350 monitor through a single conduit, be sure to <br />use a different color code for each wire or individually <br />mark each wire! <br />I. POWER WIRE INSTALLATION. <br />(See Figures 9a and 9b, "Typical TLS -350 System Wiring <br />Diagrams"). <br />Pull four (4) wires between the power panel and the TLS - <br />350 monitor; three (3) #14 AWG (or larger) color -coded <br />wires for line, neutral and chassis ground; and, one (1) # 12 <br />AWG wire for barrier ground. <br />16 CAUTION: DO NOT CONNECT THE POWER <br />SUPPLY WIRES TO A LIVE CIRCUIT. <br />9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.