Laserfiche WebLink
8. Seal wire nuts with epoxy sealant furnished with each <br />probe, using one bag for two wire nut connections. (See <br />Figure 26, "Epoxy Sealant for Two -Wire Connections.") <br />Figure 26. Epoxy Sealant for Two -Wire Connections. <br />CAUTION: IF MORE THAN TWO WIRE NUT <br />CONNECTIONS SHARE AN EPDXY SEALANT <br />BAG, THE CONNECTIONS WILL NOT BE PROP- <br />ERLY SEALED. IMPROPER SEALING OF THE <br />CONNECTIONS WILL RESULT IN INACCURATE <br />PROBE READINGS AND POSSIBLY FALSE <br />ALARM CONDITIONS. <br />WARNING: EPDXY SEALANT MAY BE IRRI- <br />TATING TO EYES AND SKIN. MAY CAUSE <br />SKIN SENSITIZATION IN SUSCEPTIBLE IN- <br />DIVIDUALS. MAY BE ABSORBED THROUGH <br />THE SKIN. EPDXY SEALANT CONTAINS EP- <br />OXY RESIN AND VINYL CYCLOHEXENE DI- <br />OXIDE. VINYL CYCLOHEXENE DIOXIDE HAS <br />CAUSED SKIN CANCER IN ANIMAL TESTS. <br />PRECAUTIONS: AVOID EYE AND SKIN CON- <br />TACT. WEAR IMPERVIOUS GLOVES AND <br />SAFETY GLASSES. USE ONLY IN WELL VEN- <br />TILATED AREAS. <br />9. Tighten the cable bushing nuts on the probe riser cap <br />and junction box to ensure a water -tight seal at the <br />probe cable entry. <br />10. Secure the riser locking cap to the top of the riser pipe. <br />A padlock may be installed for added security. <br />SECTION 6. MAGNETOSTRICTIVE PROBE <br />INSTALLATION <br />Ift WARNING: TO PROTECT YOURSELF AND <br />OTHERS FROM BEING STRUCK BY VE- <br />HICLES DURING WORK, BLOCK OFF YOUR <br />WORK AREA DURING INSTALLATION AND <br />SERVICE. <br />Site Preparation an�stallation Instructions T <br />TLS -3 ST Monitoring System <br />WARNING: TO AVOID ELECTRICAL SHOCK <br />WHICH COULD KILL YOU, BE SURE AC <br />POWER TO THE TLS MONITOR IS OFF DUR- <br />ING INSTALLATION. <br />ABOVEGROUND STORAGE TANK APPLICA- <br />TIONS: Installation Kit No. 312020-984 is required <br />for magnetostrictictive probe installation in <br />aboveground storage tanks. The kit includes: <br />1- Adaptor, Part No. 329972-001 <br />1- 5 -foot length of 3/8" Flex Conduit, Part <br />No. 576008-294 <br />2 - 3/8" Straight Liquidtight Connectors, <br />Part No. 576008-295 <br />eft WARNING: BE CAREFUL TO MAINTAIN <br />10 YOUR BALANCE WHEN WORKING ON <br />TOP OF THE STORAGE TANK. TANK <br />SURFACE IS VERY SLIPPERY. <br />16 CAUTION: IT IS RECOMMENDED THAT <br />THE RISER PIPE BE A LIGHT COLOR <br />TO REFLECT SUNLIGHT AND TO MAIN- <br />TAIN A REASONABLE TEMPERATURE. <br />PROBE MAY NOT FUNCTION PROP- <br />ERLY IF THE TEMPERATURE IN THE <br />RISER IS ABOVE 700. <br />A. TANK DIAMETER MEASUREMENT. <br />Perform the following procedure to ensure that probes are <br />installed in the proper tanks (see Figure 27, "Tank Diam- <br />eter Measurement"). Inaccurate readings will result if <br />probes are not the correct length for the given tank <br />diameter. <br />1. Measure the distance from the bottom of the tank to the <br />top of the probe riser pipe (a). <br />2. Measure the distance from the bottom of the probe riser <br />pipe to the top of the probe riser pipe (b). <br />3. Subtract (b) from (a) to determine the correct tank <br />diameter (c). <br />4. Make sure the probe length (see Figure 28, "Magnetos- <br />trictive Probe Dimensions") is correct for the tank <br />diameter. <br />PROBE RISER PIPE <br />TANK <br />b <br />a <br />C a -b -c <br />Figure 27. Tank Diameter Measurement. <br />23 <br />