COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SCHULTE
>
16900
>
2200 - Hazardous Waste Program
>
PR0507054
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/2/2020 1:27:55 PM
Creation date
4/27/2020 12:24:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0507054
PE
2229
FACILITY_ID
FA0007697
FACILITY_NAME
SAFEWAY DISTRIBUTION CENTER
STREET_NUMBER
16900
Direction
W
STREET_NAME
SCHULTE
STREET_TYPE
RD
City
TRACY
Zip
95377
APN
20943001
CURRENT_STATUS
01
SITE_LOCATION
16900 W SCHULTE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\HW\HW_2229_PR0507054_16900 W SCHULTE_.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
470
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br /> SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd/unitiii.html <br /> CONTINUATION FORM Page: 5 of 6 <br /> OFFICIAL INSPECTION REPORT Date: 03/08/11 <br /> Facility Address: 16900 Schulte Road Tracy CA Program: HW <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> 32) Failed to comply with new HW tank system assessment requirements: <br /> At time of inspection: <br /> Facility did not have tank assessment for the hazardous waste tank(s)onsite pursuant to 66265.192 CCR. Immediately have <br /> a tank assessment prepared for hazardous waste tank(s), pursuant to 66265.192 CCR. Within 30 days submit a copy to this <br /> office for review. <br /> 35) Failed to conduct daily inspections of HW tank: <br /> At time of inspection: <br /> Facility was conducting daily inspections of the HW tank but failed to document the overfill and the level of waste in the tank. <br /> The owner/operator shall inspect, and document, where present, at least once each operating day: <br /> 1. Overfill/spill control equipment <br /> 2.Aboveground portions of the tank system to detect corrosion or releases of water <br /> 3. Data gathered from monitoring equipment <br /> 4. Outside areas of the tank system including secondary containment to detect erosion or signs of releases of hazardous <br /> waste <br /> 5.The level of waste in the tank <br /> 6. Cathodic protection if present <br /> Immediately begin daily inspections, including documentation. Within 30 days submit to this office a copy of the inspection <br /> log. <br /> 49) Personnel training records incomplete/inadequate: <br /> At time of inspection: <br /> according to Butch Hobson, safety &environmental affairs manager. retail stores are implementing an environmental <br /> compliance program designed by Strong Pak, to dispose of their hazardous waste. This program has not been implemented <br /> at the distribution center. At the time of inspection a leaking container of downey was seen on a pallet. When Marc Stokes, <br /> Risk control supervisor was asked how this spill would be taken care of he responded if the spill were small, sanitation <br /> workers would respond with a scrubber and ultimately the waste would be dumped in the scrubber pit. If a sanitation worker <br /> were responding to a large spill they would use absorbent and place the waste generated in the hazardous waste container <br /> for disposal. Also seen was an empty 99% isopropyl alcohol container,which neither Butch or Marc could identify what <br /> happened to the waste. <br /> At a minimum, the training program shall be designed to ensure that facility personnel are able to respond effectively to <br /> emergencies by familiarizing them with emergency procedures, emergency equipment, and emergency systems, including <br /> where applicable, <br /> 1. procedures for using, inspecting, repairing, and replacing facility emergency and monitoring equipment; <br /> 2. key pare meters for automatic waste feed cut-off systems; <br /> 3. communications or alarm systems; <br /> 4. response to fires or explosions; <br /> 5. response to ground-water contamination incidents; and <br /> 6. shutdown of operations. <br /> Facility personnel shall take part in an annual review of the initial training received. The owner/operator shall maintain the <br /> following documents and records at the facility: <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE($122). <br /> THIS FACII-117 S SUBJECT TO REINSPECTION AT ANY TIME AT END'S CURRENT HOURLY RATE. <br /> EHD Inspecto Received By: Title: <br /> EHD 23-02 Rev 08/10/10 CONTINUATION FORM <br />