Laserfiche WebLink
E C1i, <br /> aD <br /> AUG 13 2018 <br /> Appendix V1 <br /> MONITORING SYSTEM CERTIFICATIONENVIR0,NNENTAL <br /> For Use By All Jurisdictions Within the State of California HEALT11 [-t�:, <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16, Division 3,Title 23,California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank system <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating LIST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: S B GAS & MARKET Bldg,No.: <br /> Site Address: 515 W. 11 TH STREET _ city: TRACY _ zip: 95376 <br /> Facility Contact Person: KEN Contact Phone No.: ( <br /> Make/Model of Monitoring System: INCON T S - 10 0 0 E F I Date of Testing/Servicing: 7/11/2018 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appr2eE!!te boxes to indicates ecific eguipment inspectediserviced: <br /> Tank ID: _87 OCT Tank Size: 12 K Tank ID: Tank Size: <br /> • In-Tank Gauging Probe. Model: M A G El In-Tank Gauging Probe. Model: <br /> • Annular Space or Vault Sensor. Model: E I S El Annular Space or Vault Sensor. Model: <br /> • Piping Sump/Trench Sensor(s). Model: U L S El Piping Sump/Trench Sensor(s). Model: <br /> [I Fill Sump Sensor(s). Model: Ej Fill Sump Sensor(s). Model: <br /> 0 Mechanical Line Leak Detector. Model: R J - F X - I V E] Mechanical Line Leak Detector. Model: <br /> E] Electronic Line Leak Detector. Model: El Electronic Line Leak Detector. Model: <br /> El Tank Overfill I High-Level Sensor. Model: El Tank Overfill/High-Level Sensor. Model: <br /> 0 Other(specify equipment type and model in Section E on Page 2). Ll Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: DIESEL Tank Size: 6 K Tank ID: 91 OCT Tank Size: 6 K <br /> • In-Tank Gauging Probe. Model: M A G Z In-Tank Gauging Probe. Model: M A G <br /> • Annular Space or Vault Sensor. Model: E I S 0 Annular Space or Vault Sensor. Model: SHARED W/DSL <br /> 19 Piping Sump/Trench Sensor(s). Model: U L S N Piping Sump/Trench Sensor(s). Model: U L S <br /> El Fill Sump Sensor(s). Model: El Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: 99 LD 2000 N Mechanical Line Leak Detector. Model: 99 LD 2000 <br /> ❑ Electronic Line Leak Detector. Model: El Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: E] Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). El Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: I / 2 Dispenser ID: 3 / 4 <br /> • Dispenser Containment Sensor(s). Model: BEI - 4 06 0 Dispenser Containment Sensor(s). Model: B E I - 4 0 6 <br /> • ShearValve(s). N ShearValve(s). <br /> El Dispenser Containment Float(s)and Chain(s). [I Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5 / 6 Dispenser ID: -7 / 8 <br /> • Dispenser Containment Sensor(s). Model: B E I - 4 0 6 0 Dispenser Containment Sensor(s). Model: B E I - 4 0 6 <br /> • ShearValve(s). N Shear Valve(s). <br /> [I Dispenser Containment Float(s)and Chain(s). El Dispenser Containment Float(s)and Chain(s). <br /> spenser D: Dispenser ID: <br /> El Dispenser Containment Sensor(s), Model: [I Dispenser Containment Sensor(s). Model: <br /> El ShearValve(s). [I ShearValve(s). <br /> [] Dispenser Containment Float(s)and Chain(s). [I Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply): System set-up Alarm history report <br /> Technician Name(print): ZANE NIMMO Signature: _y <br /> Certification No.: A28446 License No: 04-1676 <br /> Testing Company Name: AFFORDA-TEST Phone No. (209)744-0112 <br /> Testing Company Address: 416 2nd STREET GALT,CA 95632 Date of Testing/Servicing: 7/11/2018 <br /> Monitoring System Certification Page 1 of 4 2/21/07 <br />