Partial Excavation of Sampling Locations <br /> Using the most recent septic system installation permit on file with <br /> SJCEHD, Consultant will locate the distribution box, the 90 degree joint <br /> and the end of each leach line for the septic tank system connected to <br /> Room#108. Each of the above areas along with sampling areas located at <br /> each 20 foot section of leach line will be exposed for inspection by <br /> SJCEHD. <br /> Soil Sample Collection and Analysis <br /> Consultant proposes to advance eleven soil borings utilizing a combination <br /> of GeoProbe "direct-push" techniques and hand augur soil borings: one <br /> boring will be advanced angling beneath the septic tank, one boring will be <br /> located under the distribution box(D-Box) and one boring will be located <br /> under the 90 degree connection on the leach line. The leach line borings <br /> will be located directly below the leach line trenches at 20 foot intervals. <br /> Each boring will be advanced to approximately 4 feet below ground surface <br /> (bgs) into native soil directly underneath each sampling area. The last <br /> sampling point will coincide with the end of each leach line. <br /> Soil samples will be submitted to GeoAnalytical Laboratories for <br /> laboratory analysis. The samples will be analyzed for the following <br /> constituents: <br /> • Total recoverable petroleum hydrocarbons(TRPH) in accordance <br /> with USEPA Test Method 8015m, carbon chain C-4 through C-44; <br /> • Chloride in accordance with USEPA Method 300.0; <br /> • Volatile organic compounds with a full scan USEPA Test Method <br /> 8260B; <br /> • Ph in accordance with USEPA Test Method 150.1. <br /> Laboratory reports for soil analysis, testing methods, laboratory quality <br /> assurance/quality control(QA/QC) reports, and sample chain of custody <br /> documentation will be presented in a report of findings and <br /> recommendations. <br /> Task 5- Report Preparation <br /> Upon completion of field work and receipt of final laboratory analysis, a <br /> report will be prepared presenting the findings of the investigation. The <br /> report will include a description of the work performed including diagram <br /> of septic system, location of sampling points and results of the sampling <br /> and analysis. Conclusions and applicable recommendations will be included <br /> in the report. The report will be reviewed and signed by a California <br /> Certified Engineering Geologist. <br /> Main\D\Environmental\St.FrancisMotel\Workplan051005.wo 8 <br />