Laserfiche WebLink
15 February 2002 <br /> AGE-NC Project No 96-0229 <br /> Page 7of12 <br /> extraction The proposed aquifer pumping test will be designed to obtain general aquifer <br /> characteristics such as hydraulic conductivity, storativity,transmissivity and draw-down at a constant <br /> pumping rate Procedures for the pumping test is presented in Section 4 4 <br /> 34 SOIL VAPOR EXTRACTION PILOT TEST <br /> Following installation of wells VW-1, VW-2 and VW-3, an eight-hour SVE pilot study is proposed <br /> at the site to evaluate SVE as a remedial alternative, the results of the SVE pilot test will provide <br /> data to calculate an effective SVE radius of influence for design of a SVE remediation system <br /> Procedures for the SVE pilot test are presented in Section 4 5 <br /> 3 5 AIR SPARGING PILOT TEST <br /> Following installation of well AW-1, a 48-hour IAS pilot study is proposed at the site to evaluate <br /> IAS as a remedial alternative, the results of the IAS pilot test will provide data to calculate an <br /> • effective IAS radius of influence and determine feasibility of IAS as a remediation alternative <br /> Procedures for the IAS pilot test are presented in Section 4 6 <br /> 36 AIR SPARGING/SOIL VAPOR EXTRACTION PILOT TEST <br /> Following the 48-hour IAS pilot study, an eight-hour SVE/IAS pilot study is proposed <br /> simultaneously at the site to evaluate SVE effectiveness during IAS activities, the results of the SVE <br /> pilot test will provide data to calculate an effective SVE radius of influence for design of a SVE <br /> remediation system and determine feasibility of IAS as a remediation alternative Procedures for the <br /> SVEJAS pilot test are presented in Section 4 7 <br /> 37 REPORT PREPARATION <br /> Results of the well installations, ground water aquifer pumping test and SVE pilot study will be <br /> presented in a Problem Assessment Report(PAR) If appropriate, interim ground water remediation <br /> may be proposed,pending the completion of a Remedial Action Plan(RAP) The PAR and RAP will <br /> be in a format acceptable to the RWQCB (Appendix A guidelines), and will be reviewed and signed <br /> by a California Registered Geologist <br /> Advanced GeoEnvironmental,Inc <br />