Laserfiche WebLink
' 25 April 2005 <br /> AGE-NC Project No 95-0128 <br />' Page 6 of 8 <br /> • 25 January(start-up) TPH-g was detected from the influent SVE sample at a concentration <br />' of 14,000 gg/l,BTEX compounds were detected at 40 µg/1, 130 µg11,350 gg/l and 620 µg11, <br /> respectively, and MTBE was not detected above the detection limit concentration Toluene, <br /> ethylbenzene and xylenes were detected in the effluent SVE sample <br /> • 10 February TPH-g was detected from the influent SVE sample at a concentration of <br /> 3,800 µg/1, Toluene, ethylbenzene and xylenes were detected at 180 gg/l, 70 µg11 and <br /> L280 µg/1, respectively, MTBE was not detected above the detection limit concentration <br /> Toluene and xylenes were detected in the effluent SVE sample <br />' 4 17 February TPH-g was detected from the influent SVE sample at a concentration of <br /> 2,200 µg/l, BTEX compounds were detected at 6 2 µg/l, 150 µg11, 56 µg/l and 260 µg/1, <br /> respectively, MTBE was not detected above the detection limit concentration TPH-g, <br />' toluene, ethylbenzene and xylenes were detected in the effluent SVE sample <br /> • 21 February TPH-g was detected from the influent SVE sample at a concentration of <br /> 1,900 gg/l, BTEX compounds were detected at 3 6 µg/l, 120 µg/1, 47 µg/1 and 220 µg/1, <br /> respectively, MTBE was not detected above the detection limit concentration <br /> . e 28 February TPH-g was detected from the influent SVE sample at a concentration of <br /> t5,600 µg/l, BTEX compounds were detected at 26 µg/1, 150 µg11, 72 µg/1 and 420 µg11, <br /> respectively, MTBE was not detected above the detection limit concentration TPH-g, <br /> toluene, ethylbenzene and xylenes were detected in the effluent SVE sample <br /> • 08 March TPH-g was detected from the influent SVE sample at a concentration of <br /> 8,000 gg/l, Toluene, ethylbenzene and xylenes were detected at 680 µg/l, 350 µg/1 and <br /> 1,600 gg/l, respectively, MTBE was not detected above the detection limit concentration <br /> TPH-g, toluene, ethylbenzene and xylenes were detected in the effluent SVE sample <br /> • 15 March TPH-g was detected from the influent SVE sample at a concentration of <br /> 4,200 gg/l, Toluene, ethylbenzene and xylenes were detected at 190 gg/l, 200 µg/1 and <br /> 450 µg11, respectively, MTBE was not detected above the detection limit concentration <br />' TPH-g, toluene, ethylbenzene and xylenes were detected in the effluent SVE sample <br /> a 23 March TPH-g was detected from the influent SVE sample at a concentration of <br /> 3,100 µg/1, Toluene, ethylbenzene and xylenes were detected at 120 gg/l, 75 µg/1 and <br /> 320 µg11, respectively, MTBE was not detected above the detection limit concentration <br /> Contaminants of concern (CCs) were not detected in the effluent SVE sample <br /> 1 The analytical results are summarized in Table 3 The laboratory reports(CTEL Project Nos CT214- <br /> 0501065, 0501142, 0502069, 0502114, 0502135, 0503003, 0503079, 0503146 and 0503244) <br /> QA/QC reports and chain of custody forms are incladcd in Appendix E - <br />' Advanced GcoEnvironmental,Inc <br /> 1 <br />