My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1711
>
2300 - Underground Storage Tank Program
>
PR0231455
>
COMPLIANCE INFO_2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/6/2020 1:54:57 PM
Creation date
5/5/2020 4:53:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0231455
PE
2361
FACILITY_ID
FA0003612
FACILITY_NAME
Yosemite Avenue Arco AmPm
STREET_NUMBER
1711
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1711 E Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
459
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209) 468-3420 Fax: (209) 468-3433 Web:www.sigov.org/ehd <br /> CONTINUATION FORM Page: 4 of 5 <br /> OFFICIAL INSPECTION REPORT Date: 03/22/13 <br /> Facility Address: ARCO Station #6020 1711 E. Yosemite Ave. Manteca CA 95336 Program: UST <br /> SUMMARY OF VIOLATIONS <br /> CLASS I, CLASS II,or MINOR-Notice to Comply) <br /> and maintenance for the UST system have been completed and document the dates they were done. <br /> Ensure that designated operators performing monthly inspections at this facility are including all of the <br /> required information on the reports. <br /> 205. The March and April 2012 designated operator monthly inspection reports were not found on site. <br /> Designated operator monthly inspection reports for the previous twelve months shall be retained on site. <br /> Locate and ensure that copies of the previous twelve months of designated operator monthly inspection <br /> reports are maintained on site. Submit copies to the EHD by April 22, 2013. <br /> 206. The designated operator employee training documentation for Sunny Bhullar, Virginia Durao, and <br /> Sabi Singh was found on site to prove that they were properly trained within the last twelve months. The <br /> designated operator shall train facility employees for which he or she is responsible in the proper <br /> operation and maintenance of the UST system once every 12 months. The training shall include, but is <br /> not limited to: <br /> 1. Operation of the UST system in a manner consistent with the facility's best management practices <br /> 2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br /> 3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br /> 4. Name of the contact person(s) for emergencies and monitoring equipment alarms <br /> Ensure that employees have been trained by the designated operator, maintain the list on site, and <br /> submit a copy of the training records to the EHD by April 22, 2013. <br /> 303. The 91 and 89 fill sump sensors and the 87, 89, and 91 turbine sump sensors were touching the <br /> bottom of the sumps, but approximately two inches away from the lowest point of the sumps and not <br /> properly located to detect a leak at the earliest opportunity. The 87 fill sump sensor was touching the <br /> bottom of the sump, but approximately five inches away from the lowest point of the sump and not <br /> properly located to detect a leak at the earliest opportunity. Monitoring equipment shall be maintained to <br /> be able to detect a leak at the earliest possible opportunity. During the inspection, the technician <br /> repositioned the sump sensors to the lowest point of the sumps and located them to detect a leak at the <br /> earliest opportunity. Continue to ensure that all sensors are properly located at the lowest point of the <br /> sumps to detect a leak at the earliest opportunity. <br /> 305. The 89 fill sump sensor failed to activate an audible and visual alarm when tested to ensure <br /> continuous monitoring of the tank system. All monitoring equipment shall be maintained to activate an <br /> audible and visual alarm or stop the flow of product at the dispenser when it detects a leak. The sensor <br /> was replaced with a Veeder Root 794380-208 sensor with serial #898425 and retested during the <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> EHD Inspector: /�1 Received Ry: Title: <br /> Aris Cacapit (209) 468-3453 UI \ w, <br /> EHD 23-02-003 Rev 04/19/12 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.