Laserfiche WebLink
K. Equipment shall be wired and piped by the manufacturer or supplier. Major field modifications <br /> or changes are not allowed without the written "change order" authority by the Owner. When <br /> field changes are made, the components, materials, wiring, labeling, and construction methods <br /> shall be identical to that of the original supplied equipment. Contractor's cost to replace or <br /> rework the equipment to match original manufacturer or supplier methods shall be done at <br /> no additional cost to the Owner. <br /> L. Mating fittings, bulkhead fittings, plugs, connectors, etc. required to field interface to the <br /> equipment and panels shall be provided by the supplier when the equipment is delivered. <br /> M. All electrical and instrumentation drawings associated with the equipment shall be provided <br /> with the equipment when it is delivered to the job site. Drawings for each piece of equipment <br /> shall be placed in clear plastic packets of sufficient strength that will not tear or stretch from <br /> drawing removal and insertion. <br /> 3.3 EQUIPMENT FABRICATION, GENERAL <br /> A. Panel cutouts for devices(i.e. indicating lights, switches) shall be cut, punched, or drilled and <br /> ' smoothly finished with rounded edges. Exposed metal from cutouts that are made after the <br /> final paint finish has been applied shall be touched up with a matching paint prior to installing <br /> device. <br /> B. All doors shall be fully gasketed with nonshrinkable, water and flame resistant material. <br /> C. Bolts and screws for mounting devices on doors shall be as specified by the manufacturer, <br /> otherwise they shall have a flush head which blends into the device or door surface. No bolt <br /> or screw holding nuts shall be used on the external surface of the door. <br /> 1 D. No fastening devices shall project through the outer surfaces of equipment. <br /> ' E. Each component within the equipment shall be securely mounted on an interior subpanel or <br /> backpan and arranged for easy servicing, such that all adjustments and component removal <br /> can be accomplished without removing or disturbing other components. Mounting bolts and <br /> screws shall be front located for easy access and removal without special tools. Access behind <br /> the sub panel or backpan shall not be required for removing any component. <br /> F. A ground bus shall be provided in each enclosure or cabinet. It shall have provisions for <br /> connecting a minimum of ten grounding conductors. Screw type lugs shall be provided for <br /> ' connection of grounding conductors. All grounding conductors shall be sized as shown on <br /> plans or in accordance with NEC Table 250-95, whichever is larger. <br /> ELECTRICAL <br /> 16000 - 47 <br />