My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SEQUOIA
>
500
>
2900 - Site Mitigation Program
>
PR0505768
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/13/2020 2:53:39 PM
Creation date
5/13/2020 2:07:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
WORK PLANS
RECORD_ID
PR0505768
PE
2960
FACILITY_ID
FA0006988
FACILITY_NAME
ALDEN PARK CHEVRON
STREET_NUMBER
500
Direction
N
STREET_NAME
SEQUOIA
STREET_TYPE
AVE
City
TRACY
Zip
95376
APN
23416001
CURRENT_STATUS
01
SITE_LOCATION
500 N SEQUOIA AVE
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
192
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-13- <br /> 9 . Place probe in the atmosphere to be monitored. If the needle <br /> moves to the upper limit of the scale, change the CALIBRATE <br /> switch to the next position. <br /> 9 . 2. 2 Shutdown <br /> 1. Close the H2 supply valve and the H2 tank valve. <br /> 2. Move the INSTR switch and PUMP switch to OFF. <br /> 3. Instrument is now in shutdown configuration. <br /> 9 . 3 TLV Sniffer <br /> 9 . 3 . 1 Battery Check <br /> 1 . Turn MODE SELECTOR knob from OFF position to BATT TEST posi- <br /> tion. The meter pointer should come to rest in the BATTERY GOOD <br /> range of the scale. <br /> 9 .3 . 2 Setting Meter Pointer to Zero <br /> 1. Attach the air sampling probe connector to the instrument <br /> intake on the left side of the case by pulling back the spring <br /> collar of the connector and pressing the connector over the <br /> intake. <br /> 2. Place the instrument in the position in which the meter indi- <br /> cation will be read. <br /> Note: Heat distribution from active and reference fillaments of <br /> the detector sensor changes from vertical to horizontal position. <br /> The resulting change in electrical balance between elements <br /> causes a shift in pointer zero from one position to the other . <br /> 3 . Set MODE SELECTOR switch to ppm x 100 and operate the instru- <br /> ment for 10 minutes to allow the circuits to stabilize. <br /> 4 . In fresh air , set the ZERO ADJUST knob at the midpoint ( five <br /> full turns from either extreme position) . <br /> 5. Turn the coarse adjustment screw to move the meter pointer to <br /> zero on the meter scale. <br /> 6 . Turn the MODE SELECTOR switch to the ppm x 10 position and <br /> turn the ZERO ADJUST knob to set the pointer to zero. <br /> 7 . Turn the MODE SELECTOR switch to the ppm x 1 position and <br /> turn the ZERO ADJUST knob to set the pointer to zero. <br />