Laserfiche WebLink
Sulfuric acid solution <br /> The current hazardous waste management approach is off- site treatment and disposal . <br /> This is a waste stream that normally occurs every 12- 18 months when the acid becomes <br /> spent . But now, one of our customers has tightened the limits on the copper <br /> concentration of the solution, requiring more frequent changeouts . For this reason, <br /> monthly changeouts occur to prevent the buildup of copper in the solution. Hazardous <br /> Waste Management training will continue on an annual basis . No other source reduction <br /> measures were implemented . <br /> Solvent contaminated debris <br /> The current hazardous waste management approach is off- site disposal . The type of <br /> solvent and type of wipes are required by customer specifications . Parts must be cleaned <br /> prior to bonding, painting, etc . so it is performed throughout the manufacturing areas . <br /> With larger parts requiring solvent wiping , more surface area must be cleaned , increasing <br /> the generation of solvent contaminated debris . Annual Hazardous Waste Management <br /> training will continue . No other source reduction measures were implemented . <br /> EFFECTS OF WASTE MANAGEMENT APPROACHES <br /> Wastewater treatment <br /> The installation of the wall and rain gutter in late 2018 has yet to reduce the amount of <br /> wastewater requiring treatment . An increase of 3 , 882 pounds of wastewater was <br /> generated compared to 2014 . A decrease should be realized in the next report . <br /> Graphite pre -preg <br /> There was 660 pounds less of the graphite pre-preg waste that was generated in 2018 than <br /> in 2014 . This could be the result of using the plycutter, but most likely was due to the <br /> analytical results indicating that the material was non-hazardous reducing the amount <br /> being disposed as hazardous waste . <br /> Phosphoric acid solution <br /> Despite the installation of the wall and rain gutters to capture overspray when rinsing <br /> parts , 16 ,225 pounds less were generated compared to 2014 . This could be the result of <br /> the installation of a smaller tank ( 5 ,400 gallons compared to the current 3500 gallon <br /> tank) . It will be further evaluated in the Source Reduction Plan for 2022 and we ' ll be <br /> able to better determine if the reduction was the result of the smaller tank . <br /> Deoxidizer solution <br /> Since one of our customers tightened the copper concentration limits , we ' ve been <br /> required to change out the solution more frequently . We ' ve decided to perform monthly <br /> changeouts to keep the copper concentrations within proper range . By doing this , we <br /> i <br /> 4p� <br /> h <br />