Site Health and Safety Plan <br /> ENSAFE RS&H <br /> Stockton Metropolitan Airport, Stockton, California <br /> January 27, 2020 <br /> 15.0 SANITARY FACILITIES AND LIGHTING REQUIREMENTS <br /> Sanitary facilities, permanent or temporary, will be provided on the job site. The requirements for <br /> sanitary facilities onsite will meet all applicable standards found in CFR 29 1910.120 (n) (3). <br /> 15.1 Toilet Facilities <br /> Number of employees Minimum number of facilities <br /> 20 or fewer One <br /> More than 20, fewer than 200 One toilet seat and one urinal per 40 <br /> More than 200 One toilet seat and one urinal per 50 <br /> 15.2 Lighting <br /> Work activities are currently planned primarily during daylight hours only; however, should the need <br /> arise for nighttime operations, the following lighting scale shall be followed. <br /> Foot-Candles Area or Operations <br /> 5 General site areas <br /> 3 Excavation and waste areas, access ways, active storage areas, loading platforms, refueling, <br /> and field maintenance areas <br /> 5 Indoors, warehouses, corridors, hallways, and exit ways <br /> Tunnels, shafts, and general underground work areas(exception: minimum of <br /> 5 10 foot-candles is required at tunnel and shaft heading during drilling, mucking, and scaling. <br /> Mine Safety and Health Administration-approved cap lights shall be acceptable for use in the <br /> tunnel heading.) <br /> 10 General shops(e.g., mechanical and electrical equipment rooms, active storerooms, barracks <br /> or living quarters, locker or dressing rooms, dining areas, and indoor toilets and work rooms) <br /> 30 First-aid stations, infirmaries, and offices <br /> 33 <br />