My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS_PART 1 FILE 1
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HOWLAND
>
16777
>
2900 - Site Mitigation Program
>
PR0009015
>
WORK PLANS_PART 1 FILE 1
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/26/2020 2:11:25 PM
Creation date
5/26/2020 1:12:49 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
WORK PLANS
FileName_PostFix
PART 1 FILE 1
RECORD_ID
PR0009015
PE
2960
FACILITY_ID
FA0004094
FACILITY_NAME
J R SIMPLOT (OCCIDENTAL CHEMICAL)
STREET_NUMBER
16777
STREET_NAME
HOWLAND
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19818005
CURRENT_STATUS
02
SITE_LOCATION
16777 HOWLAND RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
TSok
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
257
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
All boreholes shall be constructed and all casing and liners set around, <br /> plumb, and true to line as defined herein. To demonstrate the compliance of his <br /> work with this requirement, the Contractor shall furnish all labor, tools, and <br /> equipment and shall make the tests described herein the manner prescribed for <br /> plumbness and alignment. These tests must be made after the complete <br /> construction of the well and before its acceptance. <br /> Plumbness and alignment shall be tested by lowering into the well to a <br /> depth of 70 feet, a section of pipe 40 feet long or a dummy of the same length. <br /> The outer diameter of the plumb shall not be more than one-half inch smaller than <br /> the diameter of the part of the casing or hole being tested. If a dummy is used, <br /> it shall consist of a rigid spindle with three rings, each ring being 12 inches wide. <br /> The rings shall be truly cylindrical and shall be spaced one at each end of the <br /> dummy and one ring in the center thereof. The central member of the dummy <br /> shall be rigid so that it will maintain the alignment of the axes of the rings. <br /> Should the plumb or dummy fail to move freely throughout the length of the <br /> casing or hole to a depth of 70 feet or should the well vary from the vertical in <br /> excess of two-thirds the smallest inside diameter of the part of the well being <br /> tested per 100 feet of depth, or beyond limitations of this test, the plumbness and <br /> alignment of the well shall be corrected by the Contractor at his own expense. <br /> Should the Contractor fail to correct such faulty alignment or plumbness, the <br /> supervising geologist may refuse to accept the well. The supervising geologist <br /> may waive the requirements of this paragraph for plumbness if: (1) the Contractor <br /> has exercised all possible care in constructing the well and the defect is due to <br /> circumstances beyond his control; (b) the utility of the completed well will not be <br /> materially affected: (c) the cost of necessary remedial measures will be excessive. <br /> In no event will the provisions in this paragraph with respect to alignment be <br /> waived. <br /> 20 <br />
The URL can be used to link to this page
Your browser does not support the video tag.