My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
ACACIA
>
525
>
2800 - Aboveground Petroleum Storage Program
>
PR0526379
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/24/2020 1:59:24 PM
Creation date
6/2/2020 3:00:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0526379
PE
2832
FACILITY_ID
FA0002864
FACILITY_NAME
DAMERON HOSPITAL
STREET_NUMBER
525
Direction
W
STREET_NAME
ACACIA
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13715304
CURRENT_STATUS
01
SITE_LOCATION
525 W ACACIA ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
104
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 3 <br /> Within Area B there is also a grease trap tank of approximately 250 gallons. This is located on <br /> Magnolia Street and has an awning over it. In the Hazardous Waste Storage room, various <br /> machine oils are kept on-site for operations and maintenance. All machine oils are stored in its <br /> original containers on anti-spill pallets. <br /> Area C—530 Building: <br /> Area C is located south of the main hospital building, bound to the north by Acacia Street, <br /> Harrison street on the west, Lincoln street to the east, and Poplar Street to the south. <br /> This area has a 250-gallon above-ground storage tank(AST)with a generator inside an outdoor <br /> enclosure. The 250-gallon AST is located within a UL approved secondary containment base <br /> tank with high level alarms and interstitial monitoring of tank bottom. <br /> The total maximum above ground storage is 10,945 gallons, and the maximum underground storage is <br /> 6,000 gallons. The total maximum storage at this site is 16,945 gallons. <br /> 1.E Permanently Closed Tanks <br /> Per§112.2 Permanently Closed(1) and(2), permanently closed tanks refer to any tank at a facility <br /> where: <br /> 1. All liquid and sludge has been removed from each container and connecting line <br /> 2. All connecting lines and piping have been disconnected from the container and blanked <br /> off, all valves (except for ventilation valves) have been closed and locked, and <br /> conspicuous signs have been posted on each container stating that it is a permanently <br /> closed container and noting the date of closure. <br /> Permanently Closed tanks are exempt from this plan per§112.1(d)2(ii)A. <br /> 1.F Drainage Pathway and Distance to Navigable Waters <br /> In accordance with§112.8(b) <br /> Dameron Hospital is stationed approximately half a mile north of McLeod Lake and half a mile south of <br /> Yosemite lake, which are both connected to the San Joaquin River. With the quantities stored on site <br /> and the countermeasures in place, it is unlikely that petroleum products will reach the waters in the event <br /> of a spill (see Section III for more information). The storm drain catch basins located nearest the above <br /> ground tanks are fitted with bio-filters to further reduce the amount of petroleum product that may enter <br /> the system due to spills occurring during the re-filling operations. See Figure A-2 in Appendix A for the <br /> exact location of these catch basins. <br /> The municipal storm drains within Dameron Hospital discharge into Yosemite Lake. <br /> 1.G Security <br /> In accordance with§112.7(g) <br /> All locations are monitored by security cameras and security personnel 24 hours per day—tank sites <br /> are well illuminated and are well secured. <br /> Area A: <br /> The 10,000-gallon AST is located at the Central Utility Plant behind a 10-foot masonry wall that <br /> is kept locked. The fill unit is also key-locked. The two (2) 250-gallon day tanks are located <br /> inside the generator room that is kept locked as well. <br /> Dameron Hospital <br /> Spill Prevention Control and Countermeasure Plan <br /> June 29,2020 <br />