My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOWER SACRAMENTO
>
8660
>
2300 - Underground Storage Tank Program
>
PR0231161
>
COMPLIANCE INFO_2002-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/13/2023 2:51:09 PM
Creation date
6/3/2020 9:45:40 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2015
RECORD_ID
PR0231161
PE
2361
FACILITY_ID
FA0003726
FACILITY_NAME
fast and easy mart #103
STREET_NUMBER
8660
STREET_NAME
LOWER SACRAMENTO
STREET_TYPE
RD
City
STOCKTON
Zip
95210
APN
079-170-390-000
CURRENT_STATUS
01
SITE_LOCATION
8660 LOWER SACRAMENTO RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231161_8660 LOWER SACRAMENTO_2002-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
484
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mar OP 09 07:23a JP Pet oleum Service 916372 873 p.5 <br />SWRCB, January 2002 Page of <br />6. PIPING SUMP TESTING <br />Test Method Developed By: ❑ Sump Manufacturer O Industry Standard X Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum X Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: Caldwell Systems Equipment Resolution: .005/30 min <br />Comments — (include information on repairs made prior to testing, and recommendedfollow-up for failed tests) <br />1 If the entire depth of the sump is not tested, specify how much was tested. 1f the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />Sump # i <br />Sump # 2 <br />Sump # 3 <br />Sump # <br />Sump Diameter: <br />42" <br />42" <br />42" <br />Sump Depth: <br />46" <br />46" <br />47" <br />Sump Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />18" <br />17" <br />17" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />16" <br />17" <br />16" <br />Condition of sump prior to testing: <br />Dry <br />Dry <br />Dry <br />Portion of Sump Tested` <br />2" above <br />Highest piping <br />penetration <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />product and water)?* <br />x Yes ❑ No <br />❑ NA <br />x Yes O No O NA <br />x Yes O No <br />O NA <br />❑ Yes O No <br />0 NA <br />Turbine shutdown response time <br />Is system programmed` for fail-safe <br />shutdown? <br />x Yes O No <br />0 NA <br />x Yes 11 No O NA <br />x Yes ❑ No <br />❑ NA <br />❑ Yes ❑ No <br />❑ NA <br />Was fail-safe verified to be <br />operational?* <br />0 Yes x No <br />O NA <br />❑ Yes x No ❑ NA <br />❑ Yes x No <br />❑ NA <br />0 Yes 0 No <br />O NA <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: <br />5 min <br />5 min <br />5 min <br />5 min <br />Test Start Time: <br />9:40 <br />10:10 <br />10:50 <br />Initial Reading (Ri): <br />00" <br />.00" <br />.00" <br />DO" <br />Test End Time: <br />10:10 <br />10:40 <br />11:20 <br />Final Reading (RF): <br />.00 <br />.00 <br />.00 <br />Test Duration: <br />30 min <br />30 min <br />30 min <br />30 min <br />Change in Reading (RF-Ro- <br />.00 <br />.00 <br />.00 <br />Pass/Fail Threshold or Criteria: <br />.005/30 min <br />.005/30 min <br />.005/30 min <br />.005/30 min <br />Test Result: <br />x Pass ❑ Fall <br />x Pass ❑ Fail <br />x Pass 0 Fail <br />O Pass 0 Fail <br />Was sensor removed for testing? <br />x Yes ❑ No <br />❑ NA <br />x Yes ❑ No ❑ NA <br />x Yes O No <br />❑ NA <br />0 Yes ❑ No <br />❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />x Yes 0 No <br />❑ NA <br />x Yes O No O NA <br />x Yes ❑ No <br />❑ NA <br />O Yes ❑ No <br />❑ NA <br />Comments — (include information on repairs made prior to testing, and recommendedfollow-up for failed tests) <br />1 If the entire depth of the sump is not tested, specify how much was tested. 1f the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.