Laserfiche WebLink
MW <br />San Joaquin County Q��N��® <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd - <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />TRACY SHELL* <br />Facility Address: <br />3725 N TRACY BLVD, TRACY <br />Date: <br />January 25, 2017 <br />SUMMARY OF VIOLATIONS <br />CLASS 1, CLPiS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />209 <br />CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br />The designated operator failed to document all the alarms from the attached alarm history on the 11/17/16 <br />designated operator monthly inspection report and failed to check that they were responded to appropriately. The <br />missing alarms include: L12 diesel fill sump piping sump fuel alarm on 10/11/16. During the monthly inspection, the <br />designated operator shall review the alarm history for the previous month, check that each alarm was documented <br />and responded to appropriately, and attach a copy of the alarm history with documentation taken in response to any <br />alarms to the monthly report. Ensure that designated operators performing monthly inspections at this facility are <br />including all of the required information on the reports. <br />This is a minor violation. <br />211 <br />CCR 2715(f) Designated operator employee training not performed or log not kept. <br />The designated operator employee training for Gloria Edward was not current. The designated operator shall train <br />facility employees for which he or she is responsible in the proper operation and maintenance of the UST system <br />once every 12 months. The training shall include, but is not limited to: <br />1. Operation of the UST system in a manner consistent with the facility's best management practices <br />2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br />3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br />4. Name of the contact person(s) for emergencies and monitoring equipment alarms <br />Ensure that employees have been trained by the designated operator, maintain the list on site, and submit a copy of <br />the training records to the EHD. <br />This is a minor violation. <br />313 <br />HSC 25290.1, 25290.2, 25291 Failure to construct, operate, and maintain primary containment as product -tight. <br />Seepage was found at or above the shear valves at dispenser 7/8 and dispenser 9/10 during the inspection. The <br />service technicians removed the seepage in the two dispensers. Continue to monitor primary piping seepage in the <br />two dispensers. If seepage continues to occur, immediately contact a licensed, trained and certified contractor to <br />repair or replace the failed components. <br />This is a repeat violation, Class II. <br />315 <br />HSC 25291(e) Water in secondary containment not removed, analyzed, and properly disposed of (pre -Jul 2003). <br />Liquid was observed in the 91 -product fill sump. If water could enter into the secondary containment by precipitation <br />or infiltration, it must be removed and disposed of properly. The service technician removed approximately one-half <br />gallon of liquid from the 91 -product fill sump. Ensure that all sumps are free of liquid. <br />This was corrected on site. <br />This is a minor violation. <br />FA0003780 PR0231417 S0001 01/2b/201I <br />EHD 23-01 Rev. 09/22/16 Page 6 of 6 Underground Storage Tank Program OIR <br />