My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELM
>
124
>
2300 - Underground Storage Tank Program
>
PR0231866
>
COMPLIANCE INFO_2006-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2020 4:02:36 PM
Creation date
6/3/2020 9:53:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2009
RECORD_ID
PR0231866
PE
2361
FACILITY_ID
FA0003957
FACILITY_NAME
AT&T California - UE020
STREET_NUMBER
124
Direction
W
STREET_NAME
ELM
STREET_TYPE
St
City
Lodi
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
124 W Elm St
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231866_124 W ELM_2006-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
483
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
"SWRCB,January 2002 Page 3 of 5 <br /> 5.SECONDARY PIPE TESTING <br /> Test Method Developed by ❑ Piping Manufacturer ® Industry Standard ❑ Professional Engineer <br /> ❑ Other(Specify) <br /> Test Method Used ® Pressure ❑ Vacuum ❑ Hydrostatic <br /> ❑ Other(Specify) <br /> Test Equipment Used:4"Dial Gauge Equipment Resolution: .l <br /> Piping Run#Spy/Rn Piping Run#Vent Piping Run# Piping Run# <br /> #UE020U001 #UE020U001 <br /> Piping Material: Plastic Fiberglass <br /> Piping Manufacturer: Total Containment A.O. Smith <br /> Piping Diameter: 4" 3" <br /> Length of Piping Run: Approx.40' Approx. 35' <br /> Product Stored: Diesel Diesel <br /> Method and location of piping-run Test Boot In Pipe Test Port @ Vent <br /> isolation: Sump Riser <br /> Wait Time between applying 15 Minutes 15 Minutes <br /> pressure/vacuum/water and starting <br /> test: <br /> Test Start Time: 9:35 AM 9:45 AM <br /> Initial Reading(Ri): 5 PSI 5 PSI <br /> Test End Time: 10:35 AM 10:45 AM <br /> Final Reading(Rf): 5 PSI 2.0 PSI <br /> Test Duration: One Hour One Hour <br /> Change in Reading(Rf-Ri): 0 3 PSI <br /> Pass/Fail Threshold or Criteria: 0 0 <br /> Test Result ® Pass ❑ Fail ❑ Pass ® Fail ❑ Pass ElFail ElPass ElFail <br /> Comments include any information on repairs made prior to testing,and recommended follow-up for failed tests <br /> Vent Secondary Line Has A Steady Drop,Could Not Pin Point Problem,No Signs Of Leakage At Pipe Ends. <br /> Supply And Return Share The Same Secondary Line(Passed). <br />
The URL can be used to link to this page
Your browser does not support the video tag.