My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELM
>
124
>
2300 - Underground Storage Tank Program
>
PR0231866
>
COMPLIANCE INFO_2006-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2020 4:02:36 PM
Creation date
6/3/2020 9:53:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2009
RECORD_ID
PR0231866
PE
2361
FACILITY_ID
FA0003957
FACILITY_NAME
AT&T California - UE020
STREET_NUMBER
124
Direction
W
STREET_NAME
ELM
STREET_TYPE
St
City
Lodi
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
124 W Elm St
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231866_124 W ELM_2006-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
483
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' If the entire depth of the sump is not tested, specify how much was tested. If the answer to @ny of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />SWRCB, January 2002 Page 4_ of _6_ <br />6. PIPING SUMP TESTING <br />Test Method Developed By: ❑ Sump Manufacturer ® Industry Standard D Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: INCON TS -STS Equipment Resolution: .002 <br />Sump #PIPING Sump # Sump # Sump # <br />Sump Diameter: 36" <br />Sump Depth: <br />50" <br />Sump Material: <br />FIBERGLASS <br />Height from Tank Top to Top of <br />2119 <br />Highest Piping Penetration: <br />Height from Tank Top to Lowest <br />18" <br />Electrical Penetration: <br />Condition of sump prior to testing: <br />GOOD <br />2" ABOVE SUMPS <br />Portion of Sump Tested' <br />HIGHEST <br />PENETRATION <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />❑ Yes ❑ No ®NA <br />❑ Yes D No ❑ NA <br />❑ Yes ❑ No DNA <br />❑ Yes D No D NA <br />product and water)?' <br />Turbine shutdown response time <br />N/A <br />Is system programmed# for fail-safe <br />❑ Yes ❑ No ®NA <br />D Yes ❑ No DNA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes D No ❑ NA <br />shutdown? <br />Was fail-safe verified to be <br />❑ Yes ❑ No ®NA <br />D Yes D No ❑ NA <br />❑ Yes ❑ No DNA <br />D Yes ❑ No ❑ NA <br />operational?* <br />Wait time between applying <br />pressure/vacuum/water and starting <br />30 MINUTES <br />test: <br />Test Start Time: <br />10:43 11:00 <br />Initial Reading (RI): <br />5.1418 5.1412 <br />Test End Time: <br />10:59 11:15 <br />1 <br />Final Reading (RF): <br />5.1411 5.1409 <br />Test Duration: <br />15 MIN 15 MIN <br />Change in Reading (RF -RI): <br />-.0007 -.0003 <br />Pass/Fail Threshold or Criteria: <br />.002 .002 <br />Test Result: <br />® Pass ❑ Fail <br />D Pass ❑ Fail <br />❑ Pass ❑ Fail <br />D Pass ❑ Fail <br />Was sensor removed for testing? <br />® Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No D NA <br />Was sensor properly replaced and <br />®Yes D No DNA <br />D Yes ❑ No DNA <br />❑ Yes D No ❑ NA <br />❑ Yes ❑ No D NA <br />verified functional after testing? <br />Comments — (include information on repairs made prior to testing and recommended follow-up for failed tests) <br />The Piping Sump passed the hydrostatic test. No repairs are needed at present time. <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to @ny of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.