STREET_NUMBER
7373
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09416023
CURRENT_STATUS
01
SITE_LOCATION
7373 WEST LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0232494_7373 WEST_2014-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
324
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
5. SECONDARY PIPE TESTING <br />Test Method Developed By: <br />❑ Piping Manufacturer <br />❑ Other (Specify) <br />® Industry Standard ❑ Professional Engineer <br />Test Method Used: <br />® Pressure <br />❑ Other (Specify) <br />❑ Vacuum ❑ Hydrostatic <br />Test Equipment Used: Test reducer boots, air compressor and gauges <br />Equipment Resolution: 0.5% of span <br />1 <br />2 <br />Piping Material: <br />Plastic <br />Plastic <br />Piping Manufacturer: <br />Flex <br />Flex <br />Piping Diameter: <br />i" <br />1" <br />Length of Piping Run: <br />100, <br />100, <br />Product Stored: <br />D <br />D <br />Method and location of <br />i in -run isolation: <br />Reducer Boots/Fittings <br />Reducer Boots/Fittings <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />10 minutes <br />10 minutes <br />FEB 0 2 2015 <br />Test Start Time: <br />A <br />11:00 AM <br />11:00 AMS <br />Initial Reading (R): <br />5 <br />5 <br />Test End Time: <br />12:00 PM <br />12:00 P <br />Final Reading (RF): <br />5 <br />5 <br />Test Duration: <br />60 Min <br />60 Min <br />Change in Reading (RF -RI): <br />0 <br />0 <br />Pass/Fail Threshold or <br />Criteria: <br />No Detectable Loss <br />No Detectable Loss <br />Test Result: <br />Pass <br />Pass <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.