My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2015-2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1960
>
2300 - Underground Storage Tank Program
>
PR0232534
>
COMPLIANCE INFO_2015-2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:32 AM
Creation date
6/3/2020 9:57:57 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015-2016
RECORD_ID
PR0232534
PE
2361
FACILITY_ID
FA0004547
FACILITY_NAME
CHEVRON STATION #201383
STREET_NUMBER
1960
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23402001
CURRENT_STATUS
01
SITE_LOCATION
1960 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\E\ELEVENTH\1960\PR0232534\RETROFIT 2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
447
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• V rn <br />L E f,'" - ", <br />�� OCT � 3 2,)115 <br />General Specification for <br />REQ THREADi II Piping System ENVIRONMENTAL <br />HFAI-w nCQ6RTAAchiT <br />Fittings shall be adhesive bonded matched tapered bell and <br />spigot or flanged. Fittings shall be certified to ASTM 0)5685. <br />Flanges shall have ANSI B16.5 Class 150 bolt hole patterns. <br />3.03 Adhesive. Adhesive shall be manufacturer's stan- <br />dard for the piping system specified. <br />3.04 Gaskets. Gaskets shall be X" thick, 60-70 du- <br />rometer full -face type suitable for the service shown on the <br />drawings and as recommended in the manufacturer's stan- <br />dard installation procedures. <br />3.05 Bolts. Nuts, and Washers. ASTM A307, Grade <br />B. hex head bolts shall be supplied. Washers shall be sup- <br />plied on all nuts and bolts. <br />3.06 Acceptable Products. RED THREAD ll as manu- <br />factured by Fiber Glass Systems, or approved equal. <br />SECTION d — Installation and Testina <br />4.01 Training and Certification. All joints installed or <br />constructed in the field shall be assembled by employees of <br />the contractor who have been trained by the pipe manufac- <br />turer. The pipe manufacturer or their authorized represen- <br />tative shall train the contractor's employees in the proper <br />joining and assembly procedures required for the project, <br />including hands-on participation by the contractor's employ- <br />ees. Each bonder shall fabricate one pipe -to -pipe and one <br />pipe -to -fitting joint that shall pass the minimum pressure test <br />for the application as stated in section 2.03A without leak- <br />ing. <br />Only bonders who have successfully completed the pressure <br />test shall bond pipe and fittings. <br />4.02 Pipe Installation, Pipe shall be installed as speci- <br />fied and indicated on the drawings. <br />The piping system shall be installed in accordance with the <br />manufacturer's current published installation procedures. <br />4.03 Testing. A cyclic hydrostatic pressure test shall <br />be conducted on the completed piping system. The piping <br />system shall be subjected to 10 pressurization cycles from <br />0 psig to 1 % times the design operating pressure as stated <br />in section 2.03.4. After the 10 cycles, the pressure shall be <br />held on the system for a minimum of 1 hour and the line in- <br />spected for leaks. <br />Test pressure shall not exceed 1;f times the maximum rated <br />pressure of the lowest rated element in the system. <br />Lines that are subjected to severe temperature cycles shall <br />be tested at 1 �/2 times the cyclic pressure rating of the lowest <br />rated component, even if the system shall operate at low <br />pressure. <br />The system shall be filled with water at the lowest point and <br />air bled oft from the highest point. Systems shall be brought <br />up to test pressure slowly to prevent water hammer or over - <br />pressurization. <br />All pipe joints shall be water tight. All joints that are found to <br />leak by observation or during testing shall be repaired by the <br />contractor and retested. <br />This suggested specification is being provided only as a general reference <br />for specifying Fiber Glass Systems piping products. It is not intended to be <br />all-inclusive or to address all of the specific applications or requirements <br />for your particular project. <br />It is the policy of Finer Glass Systems to improve its products continually. in <br />accordance with that policy, the right is reserved to make chanes in speci- <br />fications, descriptions, and illustrative material contained in this bulletin as <br />conditions warrant. Always cross-reference the bulletin date with the most <br />current version listed at www_fgspipe.com- The information contained herein <br />is general in nature and is not intended to express any warranty of any type <br />whatsoever, nor shall any be implied. <br />0 Trademark of Varco UP, Inc. FIBER GLASS SYSTEMS - A NATIONAL OILWELL VARCO COMPANY <br />0 2005, NATIONAL OILWELL VARCO 2700 W_ 65th ST, LITTLE ROCK, AR 72209.501-568-4010 . FAX 501-56811465 <br />PRINTED IN U.S-A. 1M0807 25 S. MAIN ST, SAND SPRINGS, OK 74063.918-245-6651 - FAX 918-245-7566 <br />