Page 4 of 8 <br />6. PIPING SUMP TESTING <br />Test Method Developed By: ❑ Sump Manufacturer 1XI Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: ❑ Pressure ❑ Vacuum El Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: Caldwell Level Chancle Indicator I Equipment Resolution: 0.0025 <br />Was sensor removed for testing? ® Yes ❑ No ❑ NA ® Yes ❑ No ❑ NA IRI Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />Was sensor properly replaced after IM Yes ❑ No ❑ NA ® Yes ❑ No ❑ NA ® Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />testing? <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />Reg. sump # <br />Prem. sump # <br />Diesel sump # <br />sump # <br />Sump Diameter: <br />42" <br />42" <br />42" <br />Sump Depth: <br />46" <br />46" <br />44" <br />Sump Material: <br />FG <br />FG <br />FG <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />21" <br />21" <br />22" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />14" <br />12" <br />15" <br />Condition of sump prior to testing: <br />Dry <br />Dry <br />Dry <br />Portion of Sump Tested' <br />50% <br />50% <br />50% <br />Does turbine shut down when sump <br />sensor detects liquid (both product and <br />water)?* <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ❑ NA <br />Turbine shutdown response time <br />N/A <br />N/A <br />N/A <br />Is system programmed for fail-safe <br />shutdown?' <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No IM NA <br />❑ Yes ❑ No ❑ NA <br />Was fail-safe verified to be <br />operational?* <br />❑ Yes ❑ No MINA <br />❑ Yes ❑ No ®NA <br />❑ Yes ❑ No IR NA <br />❑ Yes ❑ No LINA <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: <br />5 min <br />5 min <br />5 min <br />Test Start Time: <br />01:30 <br />02:45 <br />01:15 <br />Initial Reading (Ri): <br />0.0025 <br />0.0025 <br />0.0025 <br />Test End Time: <br />02:00 <br />03:15 <br />01:45 <br />Final Reading (RF): <br />0.0025 <br />0.0025 <br />0.0025 <br />Test Duration: <br />t/2 hr <br />1/2 hr <br />1/2 hr <br />Change in Reading (RF-Ri): <br />0 <br />0 <br />0 <br />Pass/Fail Threshold or Criteria: <br />1/16th in hour <br />1/16th in hour <br />1/16th in hour <br />Was sensor removed for testing? ® Yes ❑ No ❑ NA ® Yes ❑ No ❑ NA IRI Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />Was sensor properly replaced after IM Yes ❑ No ❑ NA ® Yes ❑ No ❑ NA ® Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />testing? <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />